This GF6018A high precision multi-product calibrator is compliance with national verification regulation: JJG124-2005 "Ammeter, voltmeter, power meter and resistance meter verification rules" and related national standards. 0.05% single-phase standard AC/DC voltage and current source, can verify level 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter & clamp meter. The source signals by using DSP and 16-bit high-speed A/D converters of controllable sine wave, the distorted wave signal source. Multifunction calibrator GF6018A is designed as universal calibration tool for electrical calibration laboratories.
The GF6018A clamp type multimeter calibrator with RS-232 port, it can be connected with PC to control, become automatic verification system. It has precise interface and multi-functions including verification, storage and query. The GF6018A multimeter calibrator adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics. It fully meets ISO17025 laboratory standards and is a good ideal test equipment for electrical engineers.
PARAMETERS
Electrical parameters | ||
---|---|---|
Power supply | Single phase AC 220V±10% or 110V±10%, 50/60HzAC | |
AC Voltage output | ||
range | 200mV, 400mV, 2000mV, 4000mV, 20V, 100V, 200V, 500V, 1000V; max 1050V |
|
Range 20V-1000V | Accuracy | ±(0.03%RD+0.02%FS) |
Stability | ≤0.01% FS /60s | |
Range 200mV-4000mV | Accuracy | ±(0.3%RD+0.2%FS) |
Stability | ≤0.04% FS /60s | |
Load capacity | 20VA | |
Waveform distortion | ≤0.3% | |
Adjustable Range | 0-120% FS (1000V not included) | |
Fineness | 5×10-5 | |
AC Current Output | ||
Range | 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A; max 24A | |
Range 0.2A-20A | Accuracy | ±(0.03%RD+0.02%FS) |
Stability | ≤0.01% FS /60s | |
Range 2mA-40mA | Accuracy | ±(0.3%RD+0.2%FS) |
Stability | ≤0.04% FS /60s | |
Load capacity | 20VA | |
Waveform distortion | ≤0.3% | |
Adjustable Range | 0-120% FS | |
Fineness | 5×10-5 | |
Frequency Output | ||
Range | 45-65Hz | |
Fineness | 0.001Hz | |
Accuracy | 0.002Hz | |
Harmonic Wave | ||
Times | 2-31 | |
Extent | 0-20% | |
Each harmonic phase fineness | 0.01·N (N is harmonic order) | |
DC voltage output | ||
Range | 200mV, 400mV, 2000mV, 4000mV, 20V, 40V, 100V, 200V, 400V, 1000V; max 1050V |
|
Load capacity | 20W | |
Adjustable range | 0-110% FS (1000V not included) | |
Adjustable fineness | 5×10-5 | |
Stability | ≤0.01% FS /60s (peak-peak value) | |
Accuracy | ±(0.03%RD+0.02%FS) | |
Ripple wave | ≤1% FS | |
DC current output | ||
Range | 20uA, 40uA, 200uA, 400uA, 2mA, 4mA, 20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A; max 22A |
|
Load capacity | 20W | |
Adjustable Range | 0-110% FS (1000V not included) | |
Adjustable Fineness | 5×10-5 | |
Stability | ≤0.01% FS /60s (peak-peak value) | |
Accuracy | ±(0.06%RD+0.04%FS) | |
Ripple wave | ≤1% FS | |
Resistance box | ||
Range | 10Ω, 20Ω, 50Ω, 100Ω, 200Ω, 500Ω, 1kΩ, 2kΩ, 5kΩ, 10 kΩ, 20kΩ, 50KΩ, 100kΩ, 200kΩ, 500kΩ, 1MΩ, 2MΩ, 5MΩ, 10MΩ, 20MΩ | |
Fineness | 0.02% | |
Adjustable Range | 0-100%FS | |
Accuracy | ±(0.3%RD+0.2%FS) | |
Clamp meter range | ||
200A | Accuracy | ±0.2% |
600A | Accuracy | ±0.5% |
1000A | Accuracy | ±1% |
Dot frequency square wave output | ||
Range | 1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz | |
Square wave amplitude | 4.5V | |
Setting accuracy | 5×10-5 | |
Communication Port | ||
Communication Port | RS232, USB | |
Standard | ||
Standard | JJG124-2005; JJF1587-2016; IEC61010, IEC 61000, IEC 61326 | |
Safety | ||
Isolation protection | IEC 61010-1:2001 | |
Measurement Category | 300 V CAT III, 600 V CAT II | |
Degree of protection | IP20 | |
Declaration of conformity | CE, CNAS certified | |
Mechanical parameters | ||
Dimension (L×W×H) (mm) | 440x360x160 | |
Weight (kg) | 12 | |
Environmental conditions | ||
Operating temperature | 20°C±10°C | |
Storage conditions | -30°C to 60°C | |
Relative humidity | ≤85%RH | |
(1) FS means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. |
Отправить запрос, связаться с поставщиком
Другие товары поставщика
GF112D 1-PHASE ELECTRICITY METER TESTER | TheGF112D is a portable one-phase power meter tester. It used for testing the error of single-phase power meter on spot. It can test harmonic,power... | |
GF112 HANDHELD SINGLE-PHASE WATT-HOUR METER TESTER | The product GF112 is a handheld 1-phase watt-hour meter tester. It mainly used in electric power departments, electric lab or field. It can measure... | |
Q125:bus bar AC 2000A clamp on current transformer | The model Q125 2000A current transformer clamp on measuring instrument can be used for a current vector for the copper bar or the power aluminum bu... | |
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | This GF6018A high precision multi-product calibrator is compliance with national verification regulation: JJG124-2005 "Ammeter, voltmeter, power me... | |
S120: 3000A cable fault analysis clamp on current transformer | The S120 current clamp is a high performance AC Clamp on current transformer probe .The S120 clamp on ct is well suited for power quality applicati... |
Похожие товары
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | Продавец: 782364 | This GF6018A high precision multi-product calibrator is compliance with national verification reg... | |
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | Продавец: 782364 | DESCRIPTIONThe GF6018A clamp type multimeter calibrator with RS-232 port, it can be connected w... | |
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | Продавец: 782364 | This GF6018A high precision multi-product calibrator is compliance with national verification reg... | |
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | Продавец: 782364 | APPLICATION ■ Power plant; ■ Universities; ■ Panel manufacturer; ■ Research institutes; ■ Electr... | |
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | Продавец: 782364 | This GF6018A high precision multi-product calibrator is compliance with national verification reg... |