GF6018A CLAMP TYPE MULTIMETER CALIBRATOR
This GF6018A high precision multi-product calibrator is compliance with national verification regulation: JJG124-2005 "Ammeter, voltmeter, power meter and resistance meter verification rules" and related national standards. 0.05% single-phase standard AC/DC voltage and current source, can verify level 0.2 and the following AC/DC voltmeter, ammeter, frequency meter, resistance meter & clamp meter. The source signals by using DSP and 16-bit high-speed A/D converters of controllable sine wave, the distorted wave signal source. Multifunction calibrator GF6018A is designed as universal calibration tool for electrical calibration laboratories.
The GF6018A clamp type multimeter calibrator with RS-232 port, it can be connected with PC to control, become automatic verification system. It has precise interface and multi-functions including verification, storage and query. The GF6018A multimeter calibrator adopts color LCD screen, chart character display is clear, with high precision, stable and reliable, convenient operation and flexible characteristics. It fully meets ISO17025 laboratory standards and is a good ideal test equipment for electrical engineers.
PARAMETERS
Electrical parameters | ||
---|---|---|
Power supply | Single phase AC 220V±10% or 110V±10%, 50/60HzAC | |
AC Voltage output | ||
range | 200mV, 400mV, 2000mV, 4000mV, 20V, 100V, 200V, 500V, 1000V; max 1050V |
|
Range 20V-1000V | Accuracy | ±(0.03%RD+0.02%FS) |
Stability | ≤0.01% FS /60s | |
Range 200mV-4000mV | Accuracy | ±(0.3%RD+0.2%FS) |
Stability | ≤0.04% FS /60s | |
Load capacity | 20VA | |
Waveform distortion | ≤0.3% | |
Adjustable Range | 0-120% FS (1000V not included) | |
Fineness | 5×10-5 | |
AC Current Output | ||
Range | 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A; max 24A | |
Range 0.2A-20A | Accuracy | ±(0.03%RD+0.02%FS) |
Stability | ≤0.01% FS /60s | |
Range 2mA-40mA | Accuracy | ±(0.3%RD+0.2%FS) |
Stability | ≤0.04% FS /60s | |
Load capacity | 20VA | |
Waveform distortion | ≤0.3% | |
Adjustable Range | 0-120% FS | |
Fineness | 5×10-5 | |
Frequency Output | ||
Range | 45-65Hz | |
Fineness | 0.001Hz | |
Accuracy | 0.002Hz | |
Harmonic Wave | ||
Times | 2-31 | |
Extent | 0-20% | |
Each harmonic phase fineness | 0.01·N (N is harmonic order) | |
DC voltage output | ||
Range | 200mV, 400mV, 2000mV, 4000mV, 20V, 40V, 100V, 200V, 400V, 1000V; max 1050V |
|
Load capacity | 20W | |
Adjustable range | 0-110% FS (1000V not included) | |
Adjustable fineness | 5×10-5 | |
Stability | ≤0.01% FS /60s (peak-peak value) | |
Accuracy | ±(0.03%RD+0.02%FS) | |
Ripple wave | ≤1% FS | |
DC current output | ||
Range | 20uA, 40uA, 200uA, 400uA, 2mA, 4mA, 20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A; max 22A |
|
Load capacity | 20W | |
Adjustable Range | 0-110% FS (1000V not included) | |
Adjustable Fineness | 5×10-5 | |
Stability | ≤0.01% FS /60s (peak-peak value) | |
Accuracy | ±(0.06%RD+0.04%FS) | |
Ripple wave | ≤1% FS | |
Resistance box | ||
Range | 10Ω, 20Ω, 50Ω, 100Ω, 200Ω, 500Ω, 1kΩ, 2kΩ, 5kΩ, 10 kΩ, 20kΩ, 50KΩ, 100kΩ, 200kΩ, 500kΩ, 1MΩ, 2MΩ, 5MΩ, 10MΩ, 20MΩ | |
Fineness | 0.02% | |
Adjustable Range | 0-100%FS | |
Accuracy | ±(0.3%RD+0.2%FS) | |
Clamp meter range | ||
200A | Accuracy | ±0.2% |
600A | Accuracy | ±0.5% |
1000A | Accuracy | ±1% |
Dot frequency square wave output | ||
Range | 1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz | |
Square wave amplitude | 4.5V | |
Setting accuracy | 5×10-5 | |
Communication Port | ||
Communication Port | RS232, USB | |
Standard | ||
Standard | JJG124-2005; JJF1587-2016; IEC61010, IEC 61000, IEC 61326 | |
Safety | ||
Isolation protection | IEC 61010-1:2001 | |
Measurement Category | 300 V CAT III, 600 V CAT II | |
Degree of protection | IP20 | |
Declaration of conformity | CE, CNAS certified | |
Mechanical parameters | ||
Dimension (L×W×H) (mm) | 440x360x160 | |
Weight (kg) | 12 | |
Environmental conditions | ||
Operating temperature | 20°C±10°C | |
Storage conditions | -30°C to 60°C | |
Relative humidity | ≤85%RH | |
(1) FS means range, the same as below; (2) RD means the setted harmonic content, harmonic can be a single output, also multiple output. |
在线联系供应商
Other supplier products
Q13: MA output 100A AC clamp on current probe | The Q13 clamp on current probe is a high accuracy mini probe for measurements to 120A AC.It can output 1mA/A, 1mV/A or 10mV/A etc. The Q13 Series c... | |
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | The GF6018A clamp type multimeter calibrator with RS-232 port, it can be connected with PC to control, become automatic verification system. It has... | |
D20: voltage output 200A AC/DC CURRENT PROBE | The Model D20 AC/DC current clamp is a portable 100A/200Arms current probe.The D20 is power by a rechargeable multimeter battery or from a 9 V powe... | |
GF312V2 PIRTABLE 3-PHAASE WATT-HOUR METER CALIBRATOR | GF312V2 is mainly used to test the error of single-phase energy meter,three-phase kWH meter and Various active and reactive energy meters. The the ... | |
P18: 200A double ratio voltage output AC current clamp | The P18 AC current clamp is a general purpose 200A AC current clamp ct designed for use with DMMs, power loggers and energy meter calibration instr... |
Same products
330037 Communication Unit Change-Over Table HS50 Original Used | 卖方: 广东聚广恒自动化设备有限公司 | 46587901 AI Accessories Green Belt Flat belt smt spare part Original Synthetic Gear Oil SHC 630 C... | |
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | 卖方: 782364 | This GF6018A high precision multi-product calibrator is compliance with national verification reg... | |
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | 卖方: 782364 | DESCRIPTIONThe GF6018A clamp type multimeter calibrator with RS-232 port, it can be connected w... | |
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | 卖方: 782364 | This GF6018A high precision multi-product calibrator is compliance with national verification reg... | |
GF6018A CLAMP TYPE MULTIMETER CALIBRATOR | 卖方: 782364 | APPLICATION ■ Power plant; ■ Universities; ■ Panel manufacturer; ■ Research institutes; ■ Electr... |