EM-5 series flue gas analyzer is a series of self-developed gas analysis products for online gas analysisof domestic as well as foreign environmental protection and industrial control. Based on UV Differential Optical Absorption Spectroscopy (DOAS) technology and chemometrics algorithm (PLS), it is able to measure the gas concentration of SO2, NO, NO2, O2, NH3, Cl2, O3, H2S, Ch3 and etc. With features of high measurement accuracy, high reliability, fast response time, wide application scope, it can be widely applied in occasions of environment online monitoring, industrial process control, safety monitoring and etc.
Depended on years of flue gas analyzer research experience and combined with practical experience of thousands of successful application cases, the analyzer has derived multiple types (standard type, low emission type, ultra-low emission type, and customized type) to meet different index requirements in different working condition.
UV DOAS technology. The optical technology platform consists of a light source, gas chamber, optical fiber and spectrograph (including the diaphragm, a holographic grating, linear array detector) and other optical components.
Ultraviolet light emitted by light source enters the gas chamber by an optical window and absorbed by measured sample gas flowed through the gas chamber. The light carrying sample absorption information will be gathered by the lens and coupled into an optical fiber and then transmits into spectrometer through fiber. After light splitting and photo-voltaic conversion, the gas absorption spectrum is obtained.
The corresponding component concentration in the gas can be calculated by analyzing the spectrum.
Note: the difference among standard analyzer, low emission analyzer, and ultra-low analyzer is the different optical path length of gas chamber: for standard analyzer, it adopts dual lens collimation system with 0.25m optical path; for low emission analyzer, it adopts multiple return structure with 1m optical path; for ultra-low emission analyzer, it uses white cell structure.
Features Of EM-5 continuous flue gas analyzer
High measurement accuracy
Minimum detection limit of SO2, NO, NO2 can reach 1mg/m3 (15m optical path)
Ultraviolet has no moisture absorption, undisturbed by moisture and dust
No cross interference between measured gases ( refer to table 1)
Measure NO and NO2 simultaneously without converter
Low detection limit
Measuring gas Interference |
SO2 |
NO |
NO2 |
O2 |
SO2 (500ppm) |
/ |
<1ppm |
no |
no |
NO (500ppm) |
no |
/ |
no |
no |
NO2 (500ppm) |
no |
<1ppm |
/ |
no |
H2O (no dew) |
no |
no |
no |
no |
CO (1000ppm) |
no |
no |
no |
no |
CO2 (20%) |
no |
no |
no |
no |
O2 (21%) |
no |
no |
no |
/ |
High reliability
Small zero drift and span drift
Modular design
No optical moving parts, without vibration influence
Strong gas chamber, low cost
Automatic adjustment spectrum technology, long maintenance-free period
Adopt pulse light source with 10-year service life
Technical Parameter Of EM-5 Flue Gas Analyzer
Measurement Principle |
UV-DOAS+PLS |
|||||||
Versions |
Regular range |
Low range |
Ultra-low range |
|||||
Ranges |
My range |
Max range |
My range |
Max range |
My range |
Max range |
||
Component |
SO2 |
0-300ppm |
0-3000ppm |
0-100ppm |
0-300ppm |
0-50ppm |
0-100ppm |
|
NO |
0-300ppm |
0-3000ppm |
0-100ppm |
0-300ppm |
0-50ppm |
0-100ppm |
||
NO2 |
0-500ppm |
0-4000pp |
0-300ppm |
0-1000ppm |
0-100ppm |
0-200ppm |
||
O2 (ECD or ZrO2) |
0-5% |
0-25% |
0-5% |
0-25% |
0-5% |
0-25% |
||
Linearity |
≤±3%F.S. |
|||||||
Repeatability |
≤2% |
|||||||
Zero Drift |
≤ ± 2% FS / 7d |
|||||||
Span Drift |
≤ ± 2% FS / 7d |
|||||||
Response Time(T90) |
≤50s |
|||||||
Working Temperature |
-20 ℃ ~ + 50 ℃ |
|||||||
Preheating Time |
No preheating |
20min |
40min |
|||||
Sample Gas Interface |
Φ6 Bi-Lok |
|||||||
Sample Gas Flow |
Range: (0.5 ~ 2) L / min, fluctuation < 25% |
|||||||
Sample Gas Pressure |
Current ambient pressure ±0.1Bar |
|||||||
SampleGas Temp. |
0 ℃ ~ + 50 ℃ |
|||||||
Sample Gas Humidity |
No condensation (under sample gas temperature) |
|||||||
4-20mA Input |
3 , configurable, 100Ω load |
|||||||
4-20mA Output |
5, output content can be configured, maximum load capacity ≤800Ω |
|||||||
Switching valueInput |
6 , configurable |
|||||||
Relay Output |
14, output content can be configured. DC30V2A |
|||||||
Digital I / O |
1×Rs232, 1×Rs485 (Support Modbus protocol) |
|||||||
Installation Method |
19’panel |
|||||||
Supply Voltage |
220VAC ± 10% |
|||||||
Rated Power |
About 100W |
About 120W |
Application Of EM-5 Flue Gas Analyzer
Coal-fired power plantCement plantIndustrial furnaceDeSOX process monitoringDeNOX process monitoringWaste incineration plantPVC process in chlor-alkali plantTitanium dioxide production processSulfur recovery processNatural gas purification processMethyl iodide analysis for the coal chemical industryOn-line air monitoring
Hangzhou Zetian Technology is committed to the integrity, strength and quality of our air quality monitor. We're internationally recognized.We have 5 gas analyzer for sale! To learn more about the flue gas analyser working principle, please contact us!
Send product request
Other supplier products
DMS-100/MS-1000 Dust Monitor | HANGZHOU ZETIAN TECHNOLOGY CO., LTDwas established in 2008, and as a fast-growing company specialized in environmental pollution monitoring and ind... | |
WDet-5000 Ammonia-Nitrogen Online Automatic Analyzer | Overview Of WDet-5000 Ammonia-Nitrogen Online Automatic Analyzer Wastewater WDet-5000 is a self-developed ammoniacal nitrogen water qualityonline ... | |
Vehicle Exhaust Remote Sensing System | The car emissions test equipmenthas attracted more and more people's attention and attention because of its advantages of speed, convenience, and w... | |
ERMS-2000-V Vertical Stationary Vehicle Exhaust Remote Sensing System | Overview ERMS2000-V vertical stationary vehicle exhaust remote sensing system is a system that sets above the multi-lane and monitors the exhaust p... | |
EM-5Hg Stack Mercury Continuous Monitoring System | Overview of Mercury Stack Monitoring Based on cold vapor atomic fluorescence spectrophotometer technology, we have developed EM-5Hg stack mercury c... |
Same products
iX361 middle frame correction clamp | Seller: Shenzhen weikexiu technology Co.,Ltd | Fixes iCF6/iA3/iX16/iX361 mobile phone screen middle frame repair jig. iFixes iCF6 non-heating sc... | |
SINGLE PHASE ELECTRICITY METER TESTER | Seller: 782364 | GF112D is a single-phase handheld electronic meter test unit in accuracy class 0.05, 0.1or 0.2, u... | |
SINGLE PHASE ELECTRICITY METER TESTER | Seller: 782364 | GF112D is a single-phase handheld electronic meter test unit in accuracy class 0.05, 0.1or 0.2, u... | |
SINGLE PHASE ELECTRICITY METER TESTER | Seller: 782364 | GF112D is a single-phase handheld electronic meter test unit in accuracy class 0.05, 0.1or 0.2, u... | |
Digital Track Gauge | Seller: Wuhan linkage track equipment co.,ltd | 产品描述 数字轨头耐磨计主要用于测量钢轨的垂直磨损和横向磨损。合理的设计使其轻巧,操作方便,阅读直观。 特征 1、直读数字型:液晶显示屏,清晰可读;无需计算,可直接读取;读数时,按... |