EM-5 Flue Gas Analyzer
Overview
EM-5 series flue gas analyzer is a series of self-developed gas analysis products for online gas analysisof domestic as well as foreign environmental protection and industrial control. Based on UV Differential Optical Absorption Spectroscopy (DOAS) technology and chemometrics algorithm (PLS), it is able to measure the gas concentration of SO2, NO, NO2, O2, NH3, Cl2, O3, H2S, Ch3 and etc. With features of high measurement accuracy, high reliability, fast response time, wide application scope, it can be widely applied in occasions of environment online monitoring, industrial process control, safety monitoring and etc.
Depended on years of flue gas analyzer research experience and combined with practical experience of thousands of successful application cases, the analyzer has derived multiple types (standard type, low emission type, ultra-low emission type, and customized type) to meet different index requirements in different working condition.
UV DOAS technology. The optical technology platform consists of a light source, gas chamber, optical fiber and spectrograph (including the diaphragm, a holographic grating, linear array detector) and other optical components.
Ultraviolet light emitted by light source enters the gas chamber by an optical window and absorbed by measured sample gas flowed through the gas chamber. The light carrying sample absorption information will be gathered by the lens and coupled into an optical fiber and then transmits into spectrometer through fiber. After light splitting and photo-voltaic conversion, the gas absorption spectrum is obtained.
The corresponding component concentration in the gas can be calculated by analyzing the spectrum.
Note: the difference among standard analyzer, low emission analyzer, and ultra-low analyzer is the different optical path length of gas chamber: for standard analyzer, it adopts dual lens collimation system with 0.25m optical path; for low emission analyzer, it adopts multiple return structure with 1m optical path; for ultra-low emission analyzer, it uses white cell structure.
Features Of EM-5 continuous flue gas analyzer
High measurement accuracy
Minimum detection limit of SO2, NO, NO2 can reach 1mg/m3 (15m optical path)
Ultraviolet has no moisture absorption, undisturbed by moisture and dust
No cross interference between measured gases ( refer to table 1)
Measure NO and NO2 simultaneously without converter
Low detection limit
Measuring gas Interference |
SO2 |
NO |
NO2 |
O2 |
SO2 (500ppm) |
/ |
<1ppm |
no |
no |
NO (500ppm) |
no |
/ |
no |
no |
NO2 (500ppm) |
no |
<1ppm |
/ |
no |
H2O (no dew) |
no |
no |
no |
no |
CO (1000ppm) |
no |
no |
no |
no |
CO2 (20%) |
no |
no |
no |
no |
O2 (21%) |
no |
no |
no |
/ |
High reliability
Small zero drift and span drift
Modular design
No optical moving parts, without vibration influence
Strong gas chamber, low cost
Automatic adjustment spectrum technology, long maintenance-free period
Adopt pulse light source with 10-year service life
Technical Parameter Of EM-5 Flue Gas Analyzer
Measurement Principle |
UV-DOAS+PLS |
|||||||
Versions |
Regular range |
Low range |
Ultra-low range |
|||||
Ranges |
My range |
Max range |
My range |
Max range |
My range |
Max range |
||
Component |
SO2 |
0-300ppm |
0-3000ppm |
0-100ppm |
0-300ppm |
0-50ppm |
0-100ppm |
|
NO |
0-300ppm |
0-3000ppm |
0-100ppm |
0-300ppm |
0-50ppm |
0-100ppm |
||
NO2 |
0-500ppm |
0-4000pp |
0-300ppm |
0-1000ppm |
0-100ppm |
0-200ppm |
||
O2 (ECD or ZrO2) |
0-5% |
0-25% |
0-5% |
0-25% |
0-5% |
0-25% |
||
Linearity |
≤±3%F.S. |
|||||||
Repeatability |
≤2% |
|||||||
Zero Drift |
≤ ± 2% FS / 7d |
|||||||
Span Drift |
≤ ± 2% FS / 7d |
|||||||
Response Time(T90) |
≤50s |
|||||||
Working Temperature |
-20 ℃ ~ + 50 ℃ |
|||||||
Preheating Time |
No preheating |
20min |
40min |
|||||
Sample Gas Interface |
Φ6 Bi-Lok |
|||||||
Sample Gas Flow |
Range: (0.5 ~ 2) L / min, fluctuation < 25% |
|||||||
Sample Gas Pressure |
Current ambient pressure ±0.1Bar |
|||||||
SampleGas Temp. |
0 ℃ ~ + 50 ℃ |
|||||||
Sample Gas Humidity |
No condensation (under sample gas temperature) |
|||||||
4-20mA Input |
3 , configurable, 100Ω load |
|||||||
4-20mA Output |
5, output content can be configured, maximum load capacity ≤800Ω |
|||||||
Switching valueInput |
6 , configurable |
|||||||
Relay Output |
14, output content can be configured. DC30V2A |
|||||||
Digital I / O |
1×Rs232, 1×Rs485 (Support Modbus protocol) |
|||||||
Installation Method |
19’panel |
|||||||
Supply Voltage |
220VAC ± 10% |
|||||||
Rated Power |
About 100W |
About 120W |
Application Of EM-5 Flue Gas Analyzer
Coal-fired power plantCement plantIndustrial furnaceDeSOX process monitoringDeNOX process monitoringWaste incineration plantPVC process in chlor-alkali plantTitanium dioxide production processSulfur recovery processNatural gas purification processMethyl iodide analysis for the coal chemical industryOn-line air monitoring
Hangzhou Zetian Technology is committed to the integrity, strength and quality of our air quality monitor. We're internationally recognized.We have 5 gas analyzer for sale! To learn more about the flue gas analyser working principle, please contact us!
Отправить запрос, связаться с поставщиком
Другие товары поставщика
AM-5100 SO2 Analyzer | Overview AM-5100 SO2 air analyzer equipmentadopts ultraviolet fluorescence technique and combines advanced micro processing technology, which could... | |
EQMS VOCs Online Monitoring System | We have air quality monitors for sale! Volatile Organic Compounds (VOCS) are carbon based compounds that pose a significant health hazard due to th... | |
EQMS-200 VOCs Online Monitoring System | Overview EQMS-200 VOCs online monitoring system adopts PID (photoionization detector ) for gas detection. The target gas is irradiated I bombarded ... | |
ERMS-2000-V Vertical Stationary Vehicle Exhaust Remote Sensing System | Overview ERMS2000-V vertical stationary vehicle exhaust remote sensing system is a system that sets above the multi-lane and monitors the exhaust p... | |
EM-5 Flue Gas Analyzer | Overview EM-5 series flue gas analyzer is a series of self-developed gas analysis products for online gas analysisof domestic as well as foreign en... |
Похожие товары
Industrial Stainless Steel Gauge | Продавец: Ningbo Huben Instrument Co.,Ltd | Industrial Stainless Steel Gaugeis ideally suited for uses on equipment where excessive vibration... | |
Valve Tappet Eddy Current Flaw Detector QMTZET-04 | Продавец: Nanjing BKN Automation System Co.,LTD | Tappet full automatic eddy current testing system is a full automatic crack hardness sorter that ... | |
QTXET-01 Ball Studs Eddy Current Sorting Machine | Продавец: Nanjing BKN Automation System Co.,LTD | There are two main types of ball studs: one is a combination of a spherical pin and an integral b... | |
GSET-551 Steel Wire Eddy Current Flaw Detector | Продавец: Nanjing BKN Automation System Co.,LTD | GSET-551 Steel Wire Eddy Current Flaw Detector Brief Introduction Using the eddy current signal... | |
Оборудование для вихретокового контроля для труб, проволоки | Продавец: Nanjing BKN Automation System Co.,LTD | ECT Eddy current testing is a non-contact testing method, which mainly uses the electromagnetic f... |