EM-5 Flue Gas Analyzer

Overview

EM-5 series flue gas analyzer is a series of self-developed gas analysis products for online gas analysisof domestic as well as foreign environmental protection and industrial control. Based on UV Differential Optical Absorption Spectroscopy (DOAS) technology and chemometrics algorithm (PLS), it is able to measure the gas concentration of SO2, NO, NO2, O2, NH3, Cl2, O3, H2S, Ch3 and etc. With features of high measurement accuracy, high reliability, fast response time, wide application scope, it can be widely applied in occasions of environment online monitoring, industrial process control, safety monitoring and etc.

Depended on years of flue gas analyzer research experience and combined with practical experience of thousands of successful application cases, the analyzer has derived multiple types (standard type, low emission type, ultra-low emission type, and customized type) to meet different index requirements in different working condition.

UV DOAS technology. The optical technology platform consists of a light source, gas chamber, optical fiber and spectrograph (including the diaphragm, a holographic grating, linear array detector) and other optical components.

Ultraviolet light emitted by light source enters the gas chamber by an optical window and absorbed by measured sample gas flowed through the gas chamber. The light carrying sample absorption information will be gathered by the lens and coupled into an optical fiber and then transmits into spectrometer through fiber. After light splitting and photo-voltaic conversion, the gas absorption spectrum is obtained.

The corresponding component concentration in the gas can be calculated by analyzing the spectrum.

Note: the difference among standard analyzer, low emission analyzer, and ultra-low analyzer is the different optical path length of gas chamber: for standard analyzer, it adopts dual lens collimation system with 0.25m optical path; for low emission analyzer, it adopts multiple return structure with 1m optical path; for ultra-low emission analyzer, it uses white cell structure.

Features Of EM-5 continuous flue gas analyzer

High measurement accuracy

Minimum detection limit of SO2, NO, NO2 can reach 1mg/m3 (15m optical path)

Ultraviolet has no moisture absorption, undisturbed by moisture and dust

No cross interference between measured gases ( refer to table 1)

Measure NO and NO2 simultaneously without converter

Low detection limit

Measuring gas

Interference

SO2

NO

NO2

O2

SO2 (500ppm)

/

<1ppm

no

no

NO (500ppm)

no

/

no

no

NO2 (500ppm)

no

<1ppm

/

no

H2O (no dew)

no

no

no

no

CO (1000ppm)

no

no

no

no

CO2 (20%)

no

no

no

no

O2 (21%)

no

no

no

/

High reliability

Small zero drift and span drift

Modular design

No optical moving parts, without vibration influence

Strong gas chamber, low cost

Automatic adjustment spectrum technology, long maintenance-free period

Adopt pulse light source with 10-year service life

Technical Parameter Of EM-5 Flue Gas Analyzer

Measurement Principle

UV-DOAS+PLS

Versions

Regular range

Low range

Ultra-low range

Ranges

My range

Max range

My range

Max range

My range

Max range

Component

SO2

0-300ppm

0-3000ppm

0-100ppm

0-300ppm

0-50ppm

0-100ppm

NO

0-300ppm

0-3000ppm

0-100ppm

0-300ppm

0-50ppm

0-100ppm

NO2

0-500ppm

0-4000pp

0-300ppm

0-1000ppm

0-100ppm

0-200ppm

O2 (ECD or ZrO2)

0-5%

0-25%

0-5%

0-25%

0-5%

0-25%

Linearity

≤±3%F.S.

Repeatability

≤2%

Zero Drift

≤ ± 2% FS / 7d

Span Drift

≤ ± 2% FS / 7d

Response Time(T90)

≤50s

Working Temperature

-20 ℃ ~ + 50 ℃

Preheating Time

No preheating

20min

40min

Sample Gas Interface

Φ6 Bi-Lok

Sample Gas Flow

Range: (0.5 ~ 2) L / min, fluctuation < 25%

Sample Gas Pressure

Current ambient pressure ±0.1Bar

SampleGas Temp.

0 ℃ ~ + 50 ℃

Sample Gas Humidity

No condensation (under sample gas temperature)

4-20mA Input

3 , configurable, 100Ω load

4-20mA Output

5, output content can be configured, maximum load capacity ≤800Ω

Switching valueInput

6 , configurable

Relay Output

14, output content can be configured. DC30V2A

Digital I / O

1×Rs232, 1×Rs485 (Support Modbus protocol)

Installation Method

19’panel

Supply Voltage

220VAC ± 10%

Rated Power

About 100W

About 120W

Application Of EM-5 Flue Gas Analyzer

Coal-fired power plantCement plantIndustrial furnaceDeSOX process monitoringDeNOX process monitoringWaste incineration plantPVC process in chlor-alkali plantTitanium dioxide production processSulfur recovery processNatural gas purification processMethyl iodide analysis for the coal chemical industryOn-line air monitoring

Hangzhou Zetian Technology is committed to the integrity, strength and quality of our air quality monitor. We're internationally recognized.We have 5 gas analyzer for sale! To learn more about the flue gas analyser working principle, please contact us!



在线联系供应商

至: HANGZHOU ZETIAN TECHNOLOGY CO., LTD
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

EM-5 Flue Gas Analyzer
EM-5 Flue Gas Analyzer Overview EM-5 series flue gas analyzer is a series of self-developed gas analysis products for online gas analysisof domestic as well as foreign en...
EM-5Hg Stack Mercury Continuous Monitoring System
EM-5Hg Stack Mercury Continuous Monitoring System Overview Based on cold vapor atomic fluorescence spectrophotometer technology, we have developed EM-5Hg stack mercury continuously monitoring syste...
DPM-6000 PM Monitor PM2.5/PM10
DPM-6000 PM Monitor PM2.5/PM10 Overview Inhalable particle content is one of the most important indexes for measuring air quality. Combining years of experience in developing env...
CODet-5000 CODcr Online Automatic Analyzer
CODet-5000 CODcr Online Automatic Analyzer Overview Of CODet-5000 CODcr Automatic Online Cod Analyzer CODet-5000 is a new self-developed online COD measurement equipment, based on the global...
ERMS-2000-V Vertical Stationary Vehicle Exhaust Remote Sensing System
ERMS-2000-V Vertical Stationary Vehicle Exhaust Remote Sensing System Overview ERMS2000-V vertical stationary vehicle exhaust remote sensing system is a system that sets above the multi-lane and monitors the exhaust p...
供应产品

Same products

iX361 中框校正夹
iX361 中框校正夹 卖方: 深圳维客修有限公司 Fixes iCF6/iA3/iX16/iX361手机屏幕中框维修治具。iFixes iCF6免加热开屏器用于手机液晶拆解无需加热。iFixes iX361中框矫正维修平台。iFixes IA3...
单相电表测试仪
单相电表测试仪 卖方: 782364 GF112D是一种单相手持式电子电表测试装置,精度等级为0.05、0.1或0.2,用于现场测试单相电表误差。测量范围从1mA到120A, 0到600V,也可用于测试交流参数—&mda...
单相电表测试仪
单相电表测试仪 卖方: 782364 GF112D是一种单相手持式电子电表测试装置,精度等级为0.05、0.1或0.2,用于现场测试单相电表误差。测量范围从1mA到120A, 0到600V,也可用于测试交流参数—&mda...
单相电表测试仪
单相电表测试仪 卖方: 782364 GF112D是一种单相手持式电子电表测试装置,精度等级为0.05、0.1或0.2,用于现场测试单相电表误差。测量范围从1mA到120A, 0到600V,也可用于测试交流参数—&mda...
数字轨距
数字轨距 卖方: Wuhan linkage track equipment co.,ltd 产品描述 数显轨头磨损仪主要用于测量钢轨的垂直磨损和横向磨损,设计合理,重量轻,操作方便,读数直观。 特征 1.数字直读式:LCD显示屏,清晰易读;无需计算,直接读数;读数时,按住...