AC REACTOR (OUTPUT REACTOR & INPUT REACTOR)

It is installed at the output end of the inverter to limit the capacitive charging current of the cable connecting the inverter and the motor, and to passivate the voltage rise rate of the PWM wave output by the inverter. When the motor cable length exceeds a certain value, it is recommended to insert a motor reactor between the inverter and the motor. It is used to compensate the capacitor recharging current when the wire is long. This larger length depends on the rating of the inverter and the type of motor cable.

application:
1. Limit dv/dt to 500V/us

2. Limit the overvoltage on the motor terminals to: 1000V to 400V~ (rms value)

1150V to 460V~ (rms value)

3. Filter interference caused by opening the contactor between the filter and the motor

4. Reduce motor ground leakage current

Technical specifications:

1. Working voltage: Ф3/380VAC-1140VAC

2. Working frequency: 50/60Hz.

3. Working current: 3A-1600A

4. Carrier frequency: 2-6KHz.

5. Insulation class: class F, H

6. Operating environment: -10~+45 ℃, the rated value will not be reduced. The higher temperature can reach +55℃, above 45℃, for every 1℃ increase, the rated current will decrease by 2% 

7. Protection level: IP00-IP22

8. Pressure drop: <4% greater than this range will cause torque loss

9. Larger current: 1.5×rated current, continuous 60S

10. Noise: ≤65dB

11. Temperature rise: ≤85K

12. Dielectric strength: iron core-winding 3000VAC/50Hz/5mA/10s no arcing breakdown (factory test)

13. Insulation resistance: 1000VDC insulation resistance ≥100MΩ

14. The altitude does not exceed 2000 meters.

15. The operating environment temperature is -25℃~+45℃, and the relative humidity does not exceed 90%.

16. There is no harmful gas around, no flammable and explosive materials.

17. The surrounding environment should have good ventilation conditions. If installed in a cabinet, ventilation equipment should be installed.

18. Executive standard:

IEC289:1987 reactor

  GB10229-88 reactor (eqvIEC289:1987)

  JB9644-1999 semiconductor electric drive reactor



Send product request

To: Fujian Hongyan Electrical Company Limited
Your E-mail:
Message text:


Send to other suppliers

Other supplier products

AC ISOLATION TRANSFORMER
AC ISOLATION TRANSFORMER Isolation transformer refers to a transformer with electrical isolation between the input winding and the output winding. The isolation transformer...
WAVE FILTER
WAVE FILTER The sine wave filter is driven by PWM inverter, and its switching frequency range is between 2-8khz, which still provides sine wave output voltage....
AC REACTOR (OUTPUT REACTOR & INPUT REACTOR)
AC REACTOR (OUTPUT REACTOR & INPUT REACTOR) It is installed at the output end of the inverter to limit the capacitive charging current of the cable connecting the inverter and the motor, and ...
All supplier products

Same products

chemical equipments
chemical equipments Seller: rachanashakti fabtech pvt ltd chemical process equipment, storage silo & platforms, Pharmaceutical equipment, Storage Tanks, Pr...
chemical equipments
chemical equipments Seller: rachanashakti fabtech pvt ltd chemical process equipment, storage silo & platforms, Pharmaceutical equipment, Storage Tanks, Pr...
WAVE FILTER
WAVE FILTER Seller: Fujian Hongyan Electrical Company Limited The sine wave filter is driven by PWM inverter, and its switching frequency range is between 2-8k...
AC REACTOR (OUTPUT REACTOR & INPUT REACTOR)
AC REACTOR (OUTPUT REACTOR & INPUT REACTOR) Seller: Fujian Hongyan Electrical Company Limited It is installed at the output end of the inverter to limit the capacitive charging current of the...
Dry magnetic-shielding shunt reactor high voltage and medium voltage
Dry magnetic-shielding shunt reactor high voltage and medium voltage Seller: Shandong Taikai Power Electronic Co., Ltd. Connected in parallel at one winding side of substation transformers at various levels. When the ...