UV Aging Test Chamber
The UV aging test chamber is suitable for all kinds of geo-synthetics, such as light resistance, weather resistance and light ageing
The exposure test of the sample was carried out in a fluorescent UV lamp vessel in a controlled environment. It can simulate and strengthen the environmental factors in the natural climate that are affected by light, heat, humidity, and rainfall as the main aging. It can simulate the accelerated test under long term exposure to obtain the results of the weather resistance of the material.
The exposure test of the sample was carried out in a fluorescent UV lamp vessel in a controlled environment. It can simulate and strengthen the environmental factors in the natural climate that are affected by light, heat, humidity, and rainfall as the main aging. It can simulate the accelerated test under long term exposure to obtain the results of the weather resistance of the material.
·JTG E50 T1164The methods of geo-synthetics for highway engineering
·GB/T 14522-93Accelerated weathering test method for plastics, coatings and rubber materials used for machinery industrial products.
·GB-T16422.3-1997Plastics--Methods of exposure to laboratory light sources--Part 3: Fluorescent UV lamps
·ISO4892-3:1994Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps
·GB/T 14522-93Accelerated weathering test method for plastics, coatings and rubber materials used for machinery industrial products.
·GB-T16422.3-1997Plastics--Methods of exposure to laboratory light sources--Part 3: Fluorescent UV lamps
·ISO4892-3:1994Plastics - Methods of exposure to laboratory light sources - Part 3: Fluorescent UV lamps
StandardStructures
· Main features: light, condensation, automatic cycle control, real-time monitoring and display
· Light temperature: RT + 10 ℃ ~ 70 ℃
· Condensation temperature: 50 ℃
· Condensation method: steam humidification condensation
· Temperature uniformity: ± 3 ℃
· Irradiation intensity: 0.55W / m2
· Light / condensation cycle: 0 ~ 9999h,59min. It can be set (such as: 4H / 4H or 8H / 8H)
· Lamp center distance: 70mm
· Sample and lamp plane distance: 55mm
· Light temperature: RT + 10 ℃ ~ 70 ℃
· Condensation temperature: 50 ℃
· Condensation method: steam humidification condensation
· Temperature uniformity: ± 3 ℃
· Irradiation intensity: 0.55W / m2
· Light / condensation cycle: 0 ~ 9999h,59min. It can be set (such as: 4H / 4H or 8H / 8H)
· Lamp center distance: 70mm
· Sample and lamp plane distance: 55mm
· UV lamp: UV-A340 or UV-B313 (optional)
· UV wavelength: (UVA) 315 ~ 400nm; (UVB) 280 ~ 315nm
· Lamp life: 1600 ~ 1800H
· Standard test piece: 75 × 150mm or customized according to customer requirements (it can be made for 21 samples)
· Control system: touch screen controller, real-time monitoring friendly interface, easy to use and easy to operate.
· Power supply: AC220V 50HZ 4.7KW
· The structure of the test chamber is made of corrosion-resistant metal material, including 8 fluorescent UV lamp, water tray, test sample rack and touch screen controller.
· Lamp power is 40W and lamp length is 1200 mm. The working area of the test chamber is in the range of 900 × 210 mm.
· The lamp is installed in a row of four rows, installed in two rows, and the lamp is arranged in parallel, and the center distance of the lamp is 70 mm.
· The test sample is fixedly mounted at a distance of 50 mm from the nearest parallel surface of the lamp surface. The test specimen and its support form the inner wall of the box, and their backs are exposed to room temperature cooling air due to the temperature difference between the test sample and the air in the box. So that the test sample surface condensation phase to produce a stable condensation conditions, the test chamber shall be of natural air convection from the bottom of the box through the outer wall of the box and the test sample.
· The water vapor is produced by the low water pan of the heating box. The water depth is not more than 25mm, and the water supply automatic control. The water dish should be cleaned regularly to prevent the formation of scale.
· The temperature of the test chamber is measured by a sensor with a width of 75 mm, height of 100 mm and a thickness of 2.5 mm on a black aluminum plate (blackboard). The blackboard shall be placed in the central area of the exposure test. The measuring range of the thermometer shall be 30 to 80 ° C , The tolerance is ± 1 ° C. Control of the lighting and condensation stages should be carried out separately, and the condensation stage is controlled by the heated water temperature.
· Standard configuration: (1) 12 UV lamp; (2) 21 sets of sample rack
· UV wavelength: (UVA) 315 ~ 400nm; (UVB) 280 ~ 315nm
· Lamp life: 1600 ~ 1800H
· Standard test piece: 75 × 150mm or customized according to customer requirements (it can be made for 21 samples)
· Control system: touch screen controller, real-time monitoring friendly interface, easy to use and easy to operate.
· Power supply: AC220V 50HZ 4.7KW
Technical Parameters
Features
Stable reliable and consistent
· The structure of the test chamber is made of corrosion-resistant metal material, including 8 fluorescent UV lamp, water tray, test sample rack and touch screen controller.
· Lamp power is 40W and lamp length is 1200 mm. The working area of the test chamber is in the range of 900 × 210 mm.
· The lamp is installed in a row of four rows, installed in two rows, and the lamp is arranged in parallel, and the center distance of the lamp is 70 mm.
· The test sample is fixedly mounted at a distance of 50 mm from the nearest parallel surface of the lamp surface. The test specimen and its support form the inner wall of the box, and their backs are exposed to room temperature cooling air due to the temperature difference between the test sample and the air in the box. So that the test sample surface condensation phase to produce a stable condensation conditions, the test chamber shall be of natural air convection from the bottom of the box through the outer wall of the box and the test sample.
· The water vapor is produced by the low water pan of the heating box. The water depth is not more than 25mm, and the water supply automatic control. The water dish should be cleaned regularly to prevent the formation of scale.
· The temperature of the test chamber is measured by a sensor with a width of 75 mm, height of 100 mm and a thickness of 2.5 mm on a black aluminum plate (blackboard). The blackboard shall be placed in the central area of the exposure test. The measuring range of the thermometer shall be 30 to 80 ° C , The tolerance is ± 1 ° C. Control of the lighting and condensation stages should be carried out separately, and the condensation stage is controlled by the heated water temperature.
· Standard configuration: (1) 12 UV lamp; (2) 21 sets of sample rack
◆ Inner box size: D450 ×W1165×H500 mm
◆ Outline dimension: D500×W1300×H1400 mm
◆ Liner material: SUS304# stainless steel plate
◆ Shell material: SUS304 # senior stainless steel plate
◆ Test piece fixture material: SUS304 stainless steel plate
◆ Imported lamp: Two rows of eight pieces, 40W / pieces
◆ Water and consumption: Clean water or distilled water 8 liters / day
◆ Control system: Color touch screen, real-time display irradiation, condensation, radiation intensity, lamp life tired. Chinese input mode, the whole automatic operation.
◆ Liner material: SUS304# stainless steel plate
◆ Shell material: SUS304 # senior stainless steel plate
◆ Test piece fixture material: SUS304 stainless steel plate
◆ Imported lamp: Two rows of eight pieces, 40W / pieces
◆ Water and consumption: Clean water or distilled water 8 liters / day
◆ Control system: Color touch screen, real-time display irradiation, condensation, radiation intensity, lamp life tired. Chinese input mode, the whole automatic operation.
在线联系供应商
Other supplier products
Water Vapour Permeability Testing Apparatus | Water Vapour Permeability Testing ApparatusStandards:JIS L1099, ASTM E96/E96M, GB/T 12704 Applications: Water Vapour Permeability Testing Apparat... | |
Wet Penetration Tester | The Wet Penetration Tester is used to determine the performance of the material in the resistance to the penetration of bacteria in the liquid duri... | |
UV Carbon Arc weather Meter | Introduction:Weatherproof test: This test is conducted to find out the impacts on some items and parts in a natural condition bysuch factors as sun... | |
Heel Fatigue Tester | TRANSLATE with x English Arabic Hebrew Polish Bulgarian Hindi Portuguese Catalan Hmong Daw Romanian ... | |
Water Vapor Permeability Testing Apparatus | Introduction:The device is a constant temperature and humidity moisture permeability test device, which is suitable for sportswear and other requir... |
Same products
DM-16BF DM-18BF New cover Electric Sprayer | 卖方: Zhejiang Huaqi Information Technology Co., LTD | The Electric Knapsack Sprayer is a game-changer in the field of agricultural pest control. Engine... | |
Simple Round Breeding Cage | 卖方: Zhejiang Huaqi Information Technology Co., LTD | The Simple Round Breeding Cage features a durable and lightweight construction, making it suitabl... | |
叙利亚-细胞储存液氮容器-液氮液位报警器 | 卖方: 河南天之道生物科技有限公司 | 精准的实验条件与安全的样本存储是科研工作顺利开展的关键要素。其中,细胞储存液氮罐作为实验室不可缺少的一种设备,在样本保存方面发挥着重要的作用。 实验室用的细胞储存液氮罐,航空铝制造,重量轻、占用... | |
意大利-液氮细胞储存罐-液氮罐液位报警器 | 卖方: 河南天驰仪器设备有限公司 | 精准的实验条件与安全的样本存储是科研工作顺利开展的关键要素。其中,细胞储存液氮罐作为实验室不可缺少的一种设备,在样本保存方面发挥着重要的作用。 实验室用的细胞储存液氮罐,航空铝制造,重量轻、占用... | |
埃及-细胞储存液氮罐-液氮液位监测仪 | 卖方: Henan Tianzhidao Biological Technology Co., Ltd. | 精准的实验条件与安全的样本存储是科研工作顺利开展的关键要素。其中,细胞储存液氮罐作为实验室不可缺少的一种设备,在样本保存方面发挥着重要的作用。 实验室用的细胞储存液氮罐,航空铝制造,重量轻、占用... |