GS8500-EX Digital Intrinsic Safety Barrier
Digital input, relay output isolated barrier, transfers digital signals (dry contact or NAMUR proximity switch) from hazardous area to safe area. Each channel can be provided to select phase reversal and to enable line fault detection. And digital output isolated barrier, with 12V/45mA output to the hazardous area, is controlled by switches and logic signal in the safe area.
This intrinsically safe barrieris suitable for driving IS devices such as solenoid valves, LED and some other low-power loads located in the hazardous area. Digital input barrierneeds an independent power supply and galvanic isolation among power supply, input and output.
Advantages of ChenzhuGS8500-EX Digital Intrinsic Safety Barrier
Ultra-thin 12.5mm
High reliability and precision
Strong EMC performance
G3 anti-corrosion
Flexible power mode
Parameter of GS8500-EX Digital Intrinsic Safety Barrier
1/1: GS8512-EX.111/2: GS8512-EX.122/2: GS8512-EX/223/3: GS8512-EX.33 |
4/4:GS8114-EX |
|
Supply Voltage |
20~35V DC |
20~35V DC |
Current Consumption |
≤30mA(GS8512-EX.11)≤40mA(GS8512-EX.12 / GS8512-EX.22)≤65mA(GS8512-EX.33) |
≤75mA |
Open circuit voltage |
≈8V |
≈8V |
Short-circuit Current |
≈8mA |
≈8mA |
Input signal |
Dry contact or NAMUR proximity switch |
Dry contact/proximity switch |
Output signal |
Relay |
Relay |
Relative humidity |
10%~90% |
10%~90% |
Response time |
≤10ms |
≤20ms |
Ambient Temperature |
-20℃~+60℃ |
-20℃~+60℃ |
Weight |
1/1:GS8519-EX.111/2:GS8519-EX.122/2:GS8519-EX.22 |
1/2:GS8519-EX.12AWith LFD function |
|
Supply Voltage |
20~35V DC |
20~35V DC |
Current Consumption |
≤40mA(GS8519-EX.11)≤60mA(GS8519-EX.12 / GS8519-EX.22) |
≤40mA |
Open circuit voltage |
≈8V |
≈8V |
Short-circuit Current |
≈8mA |
≈8mA |
Input signal |
Dry contact/proximity switch |
Dry contact/proximity switch |
Output signal |
Transistor |
Relay |
Digital Output |
|
|
Relative humidity |
10%~90% |
10%~90% |
Ambient Temperature |
-20℃~+60℃ |
-20℃~+60℃ |
Weight |
1/2:GS8515-EX |
|
Supply Voltage |
20~35V DC |
Current Consumption |
≤50mA |
Control Input |
ON/OFF control(9,10)Upper limit/lower limit control(9,10,11) |
Input signal |
Dry contact/proximity switch |
Output signal |
Relay |
Input signal |
Dry contact/proximity switch |
Response time |
≤20ms |
Ambient Temperature |
-20℃~+60℃ |
Weight |
Approx 150g |
在线联系供应商
Other supplier products
CZWB Series Temperature Transmitter | The CZWB series is an intelligent digital temperature transmitterdesigned specifically for industrial complexity. Unlike the din rail mounted type,... | |
DO Signal (SIS) Input 24V DC 5A Safety Relay | These safety relay are suitable for the application of E-Stop button, safety gate and DO signal from SIS, with several contacts output. The emer... | |
Network SPD | The SPDnetworksurge protection device, also called ethernet cable surge protector, protects a data line, including computer network signals, commun... | |
GS8500-EX Temperature Converter Intrinsic Safety Barrier | Temperature input isolated barriers, converter potentiometer/RTD/TC signals in hazardous area into 0/4~20mA or 0/1~5V signals and output to safe ar... | |
20KA AC Power SPD | SPD 20KAAC Power SPD for AC power; 220VAC, TN system, Single phase; In(8/20us): 10kA/phase, Imax: 20kA/phase; hot-pluggable; fault indication. ... |