HM-100 High-temperature Hygronom
Overview
Hygronom is also called gas moisture meteror dew-point meter, which is used to measure the humidity of flue gas emitted by pollution source. According to measured humidity, it converts wet gas concentration into dry gas concentration. In addition, it also can be used in industrial online humidity monitoring.
HM-100 flue gas hygronom (high temperature gas analyzer) is equipped with an internal high-precision capacitance digital temperature & humidity sensor. The installation method adopts the in-situ immersion installation. It is a self-developed product, of which, the core component is from Switzerland. Put the sensor inside stack to get in touch with flue gas. The probe needs preheating to prevent gas from condensation, which will affect the measurement of moisture in the flue gas. After gas contacts with the measurement chip, the chip will change capacitance to measure flue gas concentration.
Features Of HM-100 High-temperature Hygronom
• The product is convenient for installation, disassembly, and cleaning with small and compact structure
• Direct and simple key operation on site
• The probe is equipped with heat tracing function to prevent condensate water from damaging humicap and thermal resistance
• Imported core components with high-performance index and reliability
Technical Parameter Of HM-100 High-temperature Hygronom
|
Measurement Range |
H2O: 0~40.00%(volume percent)(optional) |
|
Humidity sensor |
Resistance-capacitance |
|
Temp sensor |
Pt100 platinum resistor |
|
Accuracy |
0~40.00% H2O:±2% |
|
Repeatability |
0~40.00% H2O:±1% |
|
Stability |
0~40.00% H2O:±1%F.S./7d |
|
Response time |
T90<6s |
|
Sensor life |
>2 years (under normal use) |
|
Transmitter life |
>5 years (under normal use) |
|
Power supply |
220VAC |
|
Instrument weight |
About 10kg |
|
Power consumption |
Maximum about 35VA (heating) |
|
Ambient temperature |
Transmitter: -10°C~+55°C |
|
Probe: 0~180°C (except probe cable) |
|
|
Ambient humidity |
<95%RH |
|
Sample gas flow |
(2~6)L/min |
|
Analog output (2 sets) |
Temperature and humidity, 4-20mA |
|
Communication |
Rs232 (standard) |
Typical Application Of HM-100 High-temperature Hygronom
HANGZHOU ZETIAN TECHNOLOGY CO., LTDhas gas moisture analyzer,welcome to order it.
在线联系供应商
Other supplier products
| EM-5 Online Flue Gas Analyzer | Overview Of EM-5 Continuous Flue Gas Analyzer EM-5 series continuous online flue gas analyzeris a series of self-developed gas analysis products fo... | |
| Humidity Analyzer | Hygronom is also called moisture meter or dew-point meter, which is used to measure humidity of flue gas emitted by pollution source. According to ... | |
| FT-3000 FTIR Gas Analyzer | HANGZHOU CHUNLAI (ZETIAN) TECHNOLOGY was established in 2008, and has national wide impact in China now as a fast-growing company specialized in en... | |
| WDet-7000 Integration Water Quality Online Analyzer | Overview WDet-7000 multi parameter water analyzerreal time water quality monitoring equipmentis a high-level integration of a multi-parameter water... | |
| EM-5P Portable Flue Gas Analyzer | Overview Of EM-5P Portable Flue Gas Analyzer EM-5P portable flue gas analyzersystem mainly consists of gas monitoring sensors (SO2, NOx, CO, CO2), ... |