ACREL AKH-0.66 / K SPLIT CORE CURRENT TRANSFORMER
Acrel AKH-0.66/K series split core transformersare mainly used in reconstructing projects of urban and rural power grids. The split core current sensors can be mounted easily without the removal of the primary bus. They also can be operated with electricity, which prevents the normal utilization of electricity.
Acrel AKH-0.66/K SCT current transformers series save manpower, material resources, and financial resources and improve the efficiency of users. These sct transformermatch with relay protection, measuring, and metering equipment.
AKH-0.66/K Split Core Type Current Transformers Parameters
Type |
W |
H |
D |
a |
e |
Primary Input(A) |
Net Weight(kg) |
K-30×20 |
90 |
114 |
40 |
22 |
32 |
20-400 |
|
K-60×40 |
114 |
140 |
36 |
42 |
62 |
250-2000 |
|
K-80×40 |
122 |
162 |
40 |
42 |
82 |
300-3000 |
|
K-80×50 |
114 |
159 |
36 |
52 |
82 |
250-1000 |
|
K-80×80 |
144 |
159 |
36 |
82 |
82 |
250-1000 |
|
K-120×80 |
144 |
199 |
36 |
82 |
122 |
500-1500 |
|
K-120×60 |
164 |
214 |
52 |
62 |
122 |
400-5000 |
|
K-100×40 |
144 |
194 |
A |
42 |
102 |
1000-5000 |
|
K-130×40 |
144 |
224 |
52 |
42 |
132 |
1000-5000 |
|
K-140×60 |
164 |
234 |
52 |
62 |
142 |
1000-5000 |
|
K-160×80 |
184 |
254 |
52 |
82 |
162 |
1000-5000 |
|
K-200×80 |
184 |
294 |
52 |
82 |
202 |
1000-5000 |
Type |
Ratio(A) |
Class |
Burden(VA) |
K-30x20 |
20-75/1 |
1 |
|
100-150/5(1) |
1 |
1 |
|
200/5(1) |
1 |
||
250-300/5(1) |
|||
350-400/5(1) |
|||
K-60x40 |
250-300/5(1) |
1 |
|
350-400/5(1) |
|||
500-800/5(1) |
|||
1000-1250/5(1) |
5 |
||
1500-2000/5(1) |
10 |
||
K-80x40 |
350/5(1) |
1 |
|
350-450/5(1) |
|||
500-800/5(1) |
5 |
||
1000-2000/5(1) |
10 |
||
2500-3000/5(1) |
10 |
||
K-80x50 |
250-300/5(1) |
1 |
|
400-450/5(1) |
|||
500-800/5(1) |
|||
1000/5(1) |
5 |
||
K-80x80 |
250-300/5(1) |
1 |
|
400-450/5(1) |
|||
500-800/5(1) |
|||
1000/5(1) |
5 |
||
K-100x40 |
1000-2000/5(1) |
10 |
|
2500-3000/5(1) |
10 |
||
4000-5000/5(1) |
15 |
||
K-120x60 |
400-450/5(1) |
||
500-800/5(1) |
5 |
||
1000-2000/5(1) |
10 |
||
2500-5000/5(1) |
10 |
||
K-120x80 |
500-800/5(1) |
||
1000-1200/5(1) |
5 |
||
1250-1500/5(1) |
|||
K-130x40 |
1000-2000/5(1) |
10 |
|
2500-5000/5(1) |
10 |
||
K-130x60 |
1000-2000/5(1) |
10 |
|
2500-6000/5(1) |
15 |
||
K-140x60 |
1000-2000/5(1) |
10 |
|
2500-3000/5(1) |
10 |
||
4000-5000/5(1) |
15 |
||
K-160x80 |
1000-2000/5(1) |
10 |
|
2500-3000/5(1) |
10 |
||
4000-5000/5(1) |
15 |
||
K-200x80 |
1000-2000/5(1) |
10 |
|
2500-3000/5(1) |
10 |
||
4000-5000/5(1) |
15 |
||
K-Φ20 |
100A/20mA |
1 |
15Ω |
K-Φ30 |
200A/20mA |
10Ω |
|
K-Φ30 |
300A/20mA |
10Ω |
AKH-0.66/K Series Split Type Measure Current TransformersDiagram
Hold the lower section firmly at the direction of arrow
Loosen two screws at the direction of arrow and remove them
Separate the lower section at the direction of arrow
Mount the copper bar and assemble the lower section at the direction of arrow
Hold it firmly at the direction of arrow
Hold the lower section firmly at the direction arrow, insert two screws and tighten nuts
Fix the copperbar with M5screwsand pressure plates
AKH-0.66/K Series SCT Current Transformers Uses
Our flexible split core current transformers are effectively used in reconstructing projects of urban
Split core current transformers are suitable for rural power grids to reconstruct
Split Current TransformerInstallation
Press the arrow direction firmly to open the two screws and press the lower part
Unscrew and pull out the two screws in the direction of the arrow, see "P2"
Pull the screw and pull out the lower part in the direction of the arrow
After installing on the copper busbar, close the lower part in the direction of the arrow, see "P4"
Press firmly in the direction of the arrow
Press the lower part firmly and press the arrow direction to insert the two screws into the holes and tighten the screw width, see "P6"
Then use MS screws and pressure plate to install and press the steel row according to "P6"
As one of split core current transformer manufacturers, we will do our best to meet all the needs of customers.
在线联系供应商
Other supplier products
NEW ENERGY DEVICE | Acrel new Multi Circuit Energy Meteris mainly used in solar PV system and EV charger. Nowadays, the world advocates a green, environmentally friend... | |
DATA CENTER MONITOR | Acrel based on customer needs, we integrate the characteristics of data center operation and maintenance, from the bottom monitoring of equipment t... | |
ACREL MEDICAL IT ISOLATED POWER SYSTEM | Acrel medical isolated power supplysystems are mainly used in operating rooms, ICU/CCU intensive care units, premature infant care units, delivery ... | |
SMART GATEWAY | Acrel smart geteway currently include AWT100 wireless communication terminal, ANet smart gateway. these products mainly realizes the function of ... | |
ACREL ADW300 WIRELESS ENERGY METER | Acrel ADW300wireless smart acrel energy meteris mainly used to measure three-phase active electric energy of the low-voltage networks. With RS485 c... |
Same products
CSD16301Q2 TRANSISTOR MOSFET N-CH 25V 6SON TEXAS INSTRUMENTS | 卖方: ZK Electronic Technology Co., Limited | Part Number:CSD16301Q2 Description:CSD16301Q2 TRANSISTOR MOSFET N-CH 25V 6SON TEXAS INSTRUMENTS ... | |
CAPACITOR EEF-CX0J10CAPACITOR EEF-CX0J101R PANASONIC SMD SPEC POLYMER 100UF 6.3V SMD LF1R PANASONIC SMD SPEC POLYMER 100UF 6.3V SMD LF | 卖方: ZK Electronic Technology Co., Limited | Part name:EEF-CX0J101R Description:CAPACITOR EEF-CX0J101R PANASONIC SMD SPEC POLYMER 100UF 6.3V ... | |
Heavy Copper PCB Manufacturer | 卖方: Xinfeng Huihe Circuits Co., Ltd. | Heavy Copper PCB, pcb fabrication up to 12oz, large current, pcb circuitfabrication base material... | |
8 Layer ENIG Half Hole Custom PCB | 卖方: Xinfeng Huihe Circuits Co., Ltd. | Number of layers: 8 Surface finish: ENIG Base material: FR4 Outer Layer W/S: 4/3mil Inner lay... | |
4 Layer ENIG Impedance Control Half Hole PCB Electric Circuit Board | 卖方: Xinfeng Huihe Circuits Co., Ltd. | Number of layers: 4 Surface finish: ENIG Base material: FR4 Outer Layer W/S: 6/4mil Inner lay... |