Acrel AKH-0.66/K series split core transformersare mainly used in reconstructing projects of urban and rural power grids. The split core current sensors can be mounted easily without the removal of the primary bus. They also can be operated with electricity, which prevents the normal utilization of electricity.
Acrel AKH-0.66/K SCT current transformers series save manpower, material resources, and financial resources and improve the efficiency of users. These sct transformermatch with relay protection, measuring, and metering equipment.
AKH-0.66/K Split Core Type Current Transformers Parameters
|
Type |
W |
H |
D |
a |
e |
Primary Input(A) |
Net Weight(kg) |
|
K-30×20 |
90 |
114 |
40 |
22 |
32 |
20-400 |
|
|
K-60×40 |
114 |
140 |
36 |
42 |
62 |
250-2000 |
|
|
K-80×40 |
122 |
162 |
40 |
42 |
82 |
300-3000 |
|
|
K-80×50 |
114 |
159 |
36 |
52 |
82 |
250-1000 |
|
|
K-80×80 |
144 |
159 |
36 |
82 |
82 |
250-1000 |
|
|
K-120×80 |
144 |
199 |
36 |
82 |
122 |
500-1500 |
|
|
K-120×60 |
164 |
214 |
52 |
62 |
122 |
400-5000 |
|
|
K-100×40 |
144 |
194 |
A |
42 |
102 |
1000-5000 |
|
|
K-130×40 |
144 |
224 |
52 |
42 |
132 |
1000-5000 |
|
|
K-140×60 |
164 |
234 |
52 |
62 |
142 |
1000-5000 |
|
|
K-160×80 |
184 |
254 |
52 |
82 |
162 |
1000-5000 |
|
|
K-200×80 |
184 |
294 |
52 |
82 |
202 |
1000-5000 |
|
Type |
Ratio(A) |
Class |
Burden(VA) |
|
K-30x20 |
20-75/1 |
1 |
|
|
100-150/5(1) |
1 |
1 |
|
|
200/5(1) |
1 |
||
|
250-300/5(1) |
|||
|
350-400/5(1) |
|||
|
K-60x40 |
250-300/5(1) |
1 |
|
|
350-400/5(1) |
|||
|
500-800/5(1) |
|||
|
1000-1250/5(1) |
5 |
||
|
1500-2000/5(1) |
10 |
||
|
K-80x40 |
350/5(1) |
1 |
|
|
350-450/5(1) |
|||
|
500-800/5(1) |
5 |
||
|
1000-2000/5(1) |
10 |
||
|
2500-3000/5(1) |
10 |
||
|
K-80x50 |
250-300/5(1) |
1 |
|
|
400-450/5(1) |
|||
|
500-800/5(1) |
|||
|
1000/5(1) |
5 |
||
|
K-80x80 |
250-300/5(1) |
1 |
|
|
400-450/5(1) |
|||
|
500-800/5(1) |
|||
|
1000/5(1) |
5 |
||
|
K-100x40 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-120x60 |
400-450/5(1) |
||
|
500-800/5(1) |
5 |
||
|
1000-2000/5(1) |
10 |
||
|
2500-5000/5(1) |
10 |
||
|
K-120x80 |
500-800/5(1) |
||
|
1000-1200/5(1) |
5 |
||
|
1250-1500/5(1) |
|||
|
K-130x40 |
1000-2000/5(1) |
10 |
|
|
2500-5000/5(1) |
10 |
||
|
K-130x60 |
1000-2000/5(1) |
10 |
|
|
2500-6000/5(1) |
15 |
||
|
K-140x60 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-160x80 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-200x80 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-Φ20 |
100A/20mA |
1 |
15Ω |
|
K-Φ30 |
200A/20mA |
10Ω |
|
|
K-Φ30 |
300A/20mA |
10Ω |
AKH-0.66/K Series Split Type Measure Current TransformersDiagram
Hold the lower section firmly at the direction of arrow
Loosen two screws at the direction of arrow and remove them
Separate the lower section at the direction of arrow
Mount the copper bar and assemble the lower section at the direction of arrow
Hold it firmly at the direction of arrow
Hold the lower section firmly at the direction arrow, insert two screws and tighten nuts
Fix the copperbar with M5screwsand pressure plates
AKH-0.66/K Series SCT Current Transformers Uses
Our flexible split core current transformers are effectively used in reconstructing projects of urban
Split core current transformers are suitable for rural power grids to reconstruct
Split Current TransformerInstallation
Press the arrow direction firmly to open the two screws and press the lower part
Unscrew and pull out the two screws in the direction of the arrow, see "P2"
Pull the screw and pull out the lower part in the direction of the arrow
After installing on the copper busbar, close the lower part in the direction of the arrow, see "P4"
Press firmly in the direction of the arrow
Press the lower part firmly and press the arrow direction to insert the two screws into the holes and tighten the screw width, see "P6"
Then use MS screws and pressure plate to install and press the steel row according to "P6"
As one of split core current transformer manufacturers, we will do our best to meet all the needs of customers.
在线联系供应商
Other supplier products
| ACREL PZ72L-DE MULTIFUNCTION DC ENERGY METER | PZ series intelligent DC atorch electric energy meteris designed for applications such as DC panels, solar power, telecommunications base stations,... | |
| ISOLATED POWER SYSTEMS | Acrel Isolated power monitoring and control systemare mainly used in the medical and industrial sectors. The medical IT system is mainly designed f... | |
| The Working Principle of Active Power Filter | Active power filter is a new type of power electronic device used to dynamically suppress harmonics and compensate reactive power. It can quickly t... | |
| ENERGY MANAGEMENT DEVICES | As one of remote terminal units manufacturers, Acrel provides various programmable energy meter, programmable power meter types for sale. Acrel pow... | |
| NEW ENERGY DEVICE | Acrel new energy insulation monitoring device abbis mainly used in solar PV system and EV charger. Nowadays, the world advocates a green, environme... |
Same products
| Onboard Multi-Network Router | 卖方: ZHUHAI ZTLX NETWORK TECHNOLOGY CO.,LTD | Onboard Multi-Network Router Reliable Onboard Connectivity for Railway Communication Systems Th... | |
| Onboard Video-on-Demand (VOD) Server | 卖方: ZHUHAI ZTLX NETWORK TECHNOLOGY CO.,LTD | Onboard Video-on-Demand (VOD) Server Designed for railway Wi-Fi systems,the ZTDC series video-on... | |
| Onboard Wireless Access Point(AP) | 卖方: ZHUHAI ZTLX NETWORK TECHNOLOGY CO.,LTD | Onboard Wireless Access Point(AP) Onboard Wireless Access Point (AP)for Railway Passenger Servic... | |
| Onboard 5G Multi-Network Router | 卖方: ZHUHAI ZTLX NETWORK TECHNOLOGY CO.,LTD | Onboard 5G Multi-Network Router Onboard 5G Router for Railway Onboard Communication Systems Hig... | |
| Onboard 4G Multi-Network Router | 卖方: ZHUHAI ZTLX NETWORK TECHNOLOGY CO.,LTD | Onboard 4G Multi-Network Router Onboard 4G Router for Railway Onboard Communication Systems The... |