ACREL AKH-0.66 / K SPLIT CORE CURRENT TRANSFORMER
Acrel AKH-0.66/K series split core transformersare mainly used in reconstructing projects of urban and rural power grids. The split core current sensors can be mounted easily without the removal of the primary bus. They also can be operated with electricity, which prevents the normal utilization of electricity.
Acrel AKH-0.66/K SCT current transformers series save manpower, material resources, and financial resources and improve the efficiency of users. These sct transformermatch with relay protection, measuring, and metering equipment.
AKH-0.66/K Split Core Type Current Transformers Parameters
|
Type |
W |
H |
D |
a |
e |
Primary Input(A) |
Net Weight(kg) |
|
K-30×20 |
90 |
114 |
40 |
22 |
32 |
20-400 |
|
|
K-60×40 |
114 |
140 |
36 |
42 |
62 |
250-2000 |
|
|
K-80×40 |
122 |
162 |
40 |
42 |
82 |
300-3000 |
|
|
K-80×50 |
114 |
159 |
36 |
52 |
82 |
250-1000 |
|
|
K-80×80 |
144 |
159 |
36 |
82 |
82 |
250-1000 |
|
|
K-120×80 |
144 |
199 |
36 |
82 |
122 |
500-1500 |
|
|
K-120×60 |
164 |
214 |
52 |
62 |
122 |
400-5000 |
|
|
K-100×40 |
144 |
194 |
A |
42 |
102 |
1000-5000 |
|
|
K-130×40 |
144 |
224 |
52 |
42 |
132 |
1000-5000 |
|
|
K-140×60 |
164 |
234 |
52 |
62 |
142 |
1000-5000 |
|
|
K-160×80 |
184 |
254 |
52 |
82 |
162 |
1000-5000 |
|
|
K-200×80 |
184 |
294 |
52 |
82 |
202 |
1000-5000 |
|
Type |
Ratio(A) |
Class |
Burden(VA) |
|
K-30x20 |
20-75/1 |
1 |
|
|
100-150/5(1) |
1 |
1 |
|
|
200/5(1) |
1 |
||
|
250-300/5(1) |
|||
|
350-400/5(1) |
|||
|
K-60x40 |
250-300/5(1) |
1 |
|
|
350-400/5(1) |
|||
|
500-800/5(1) |
|||
|
1000-1250/5(1) |
5 |
||
|
1500-2000/5(1) |
10 |
||
|
K-80x40 |
350/5(1) |
1 |
|
|
350-450/5(1) |
|||
|
500-800/5(1) |
5 |
||
|
1000-2000/5(1) |
10 |
||
|
2500-3000/5(1) |
10 |
||
|
K-80x50 |
250-300/5(1) |
1 |
|
|
400-450/5(1) |
|||
|
500-800/5(1) |
|||
|
1000/5(1) |
5 |
||
|
K-80x80 |
250-300/5(1) |
1 |
|
|
400-450/5(1) |
|||
|
500-800/5(1) |
|||
|
1000/5(1) |
5 |
||
|
K-100x40 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-120x60 |
400-450/5(1) |
||
|
500-800/5(1) |
5 |
||
|
1000-2000/5(1) |
10 |
||
|
2500-5000/5(1) |
10 |
||
|
K-120x80 |
500-800/5(1) |
||
|
1000-1200/5(1) |
5 |
||
|
1250-1500/5(1) |
|||
|
K-130x40 |
1000-2000/5(1) |
10 |
|
|
2500-5000/5(1) |
10 |
||
|
K-130x60 |
1000-2000/5(1) |
10 |
|
|
2500-6000/5(1) |
15 |
||
|
K-140x60 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-160x80 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-200x80 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-Φ20 |
100A/20mA |
1 |
15Ω |
|
K-Φ30 |
200A/20mA |
10Ω |
|
|
K-Φ30 |
300A/20mA |
10Ω |
AKH-0.66/K Series Split Type Measure Current TransformersDiagram
Hold the lower section firmly at the direction of arrow
Loosen two screws at the direction of arrow and remove them
Separate the lower section at the direction of arrow
Mount the copper bar and assemble the lower section at the direction of arrow
Hold it firmly at the direction of arrow
Hold the lower section firmly at the direction arrow, insert two screws and tighten nuts
Fix the copperbar with M5screwsand pressure plates
AKH-0.66/K Series SCT Current Transformers Uses
Our flexible split core current transformers are effectively used in reconstructing projects of urban
Split core current transformers are suitable for rural power grids to reconstruct
Split Current TransformerInstallation
Press the arrow direction firmly to open the two screws and press the lower part
Unscrew and pull out the two screws in the direction of the arrow, see "P2"
Pull the screw and pull out the lower part in the direction of the arrow
After installing on the copper busbar, close the lower part in the direction of the arrow, see "P4"
Press firmly in the direction of the arrow
Press the lower part firmly and press the arrow direction to insert the two screws into the holes and tighten the screw width, see "P6"
Then use MS screws and pressure plate to install and press the steel row according to "P6"
As one of split core current transformer manufacturers, we will do our best to meet all the needs of customers.
在线联系供应商
Other supplier products
| NEW ENERGY DEVICE | Acrel new Multi Circuit Energy Meteris mainly used in solar PV system and EV charger. Nowadays, the world advocates a green, environmentally friend... | |
| DATA CENTER MONITOR | Multi-Circuit Monitoring Wireless Communication Terminal Acrel based on customer needs, we integrate the characteristics of data center opera... | |
| MICROGRID ENERGY MANAGEMENT SYSTEM | Under the threat of global energy shortage and the urgency to curb environmental pollution, the demand for energy conservation and emission reducti... | |
| DATA CENTER MONITOR | Acrel based on customer needs, we integrate the characteristics of data center operation and maintenance, from the bottom monitoring of equipment t... | |
| ELECTRICAL MONITORING & PROTECTION DEVICE | Acrel electrical overload protection devicesprovide solutions for 0.4kv-35kv power distribution system, which include programmable panel energy met... |
Same products
| Air insulated Dry type transformer VPI | 卖方: TAILI ELECTRIC CO.,LTD. | Air insulated Dry type transformer VPI TAILI SG(B) air-barrier dry-type transformer( VPI) is des... | |
| Cast Resin Dry Type Transformer with Cooling Fan | 卖方: TAILI ELECTRIC CO.,LTD. | Cast Resin Dry Type Transformer with Cooling Fan Taili’s advanced epoxy resin casting proc... | |
| 1250kVA Dry type Transformer for Bangladesh | 卖方: TAILI ELECTRIC CO.,LTD. | 1250kVA Dry type Transformer for Bangladesh Taili's advanced epoxy resin casting process ensures... | |
| 35kV Dry-type transformer with OLTC | 卖方: TAILI ELECTRIC CO.,LTD. | 35kV Dry-type transformer with OLTC Taili's35kV Dry-type Transformer with OLTC (On-Load Tap Chan... | |
| Cast Resin Dry Type Transformer | 卖方: TAILI ELECTRIC CO.,LTD. | Cast Resin Dry Type Transformer IEC/ANSICast Resin TransformersfromTAILI Electric, is difference... |