ACREL AKH-0.66 / K SPLIT CORE CURRENT TRANSFORMER
Acrel AKH-0.66/K series split core transformersare mainly used in reconstructing projects of urban and rural power grids. The split core current sensors can be mounted easily without the removal of the primary bus. They also can be operated with electricity, which prevents the normal utilization of electricity.
Acrel AKH-0.66/K SCT current transformers series save manpower, material resources, and financial resources and improve the efficiency of users. These sct transformermatch with relay protection, measuring, and metering equipment.
AKH-0.66/K Split Core Type Current Transformers Parameters
|
Type |
W |
H |
D |
a |
e |
Primary Input(A) |
Net Weight(kg) |
|
K-30×20 |
90 |
114 |
40 |
22 |
32 |
20-400 |
|
|
K-60×40 |
114 |
140 |
36 |
42 |
62 |
250-2000 |
|
|
K-80×40 |
122 |
162 |
40 |
42 |
82 |
300-3000 |
|
|
K-80×50 |
114 |
159 |
36 |
52 |
82 |
250-1000 |
|
|
K-80×80 |
144 |
159 |
36 |
82 |
82 |
250-1000 |
|
|
K-120×80 |
144 |
199 |
36 |
82 |
122 |
500-1500 |
|
|
K-120×60 |
164 |
214 |
52 |
62 |
122 |
400-5000 |
|
|
K-100×40 |
144 |
194 |
A |
42 |
102 |
1000-5000 |
|
|
K-130×40 |
144 |
224 |
52 |
42 |
132 |
1000-5000 |
|
|
K-140×60 |
164 |
234 |
52 |
62 |
142 |
1000-5000 |
|
|
K-160×80 |
184 |
254 |
52 |
82 |
162 |
1000-5000 |
|
|
K-200×80 |
184 |
294 |
52 |
82 |
202 |
1000-5000 |
|
Type |
Ratio(A) |
Class |
Burden(VA) |
|
K-30x20 |
20-75/1 |
1 |
|
|
100-150/5(1) |
1 |
1 |
|
|
200/5(1) |
1 |
||
|
250-300/5(1) |
|||
|
350-400/5(1) |
|||
|
K-60x40 |
250-300/5(1) |
1 |
|
|
350-400/5(1) |
|||
|
500-800/5(1) |
|||
|
1000-1250/5(1) |
5 |
||
|
1500-2000/5(1) |
10 |
||
|
K-80x40 |
350/5(1) |
1 |
|
|
350-450/5(1) |
|||
|
500-800/5(1) |
5 |
||
|
1000-2000/5(1) |
10 |
||
|
2500-3000/5(1) |
10 |
||
|
K-80x50 |
250-300/5(1) |
1 |
|
|
400-450/5(1) |
|||
|
500-800/5(1) |
|||
|
1000/5(1) |
5 |
||
|
K-80x80 |
250-300/5(1) |
1 |
|
|
400-450/5(1) |
|||
|
500-800/5(1) |
|||
|
1000/5(1) |
5 |
||
|
K-100x40 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-120x60 |
400-450/5(1) |
||
|
500-800/5(1) |
5 |
||
|
1000-2000/5(1) |
10 |
||
|
2500-5000/5(1) |
10 |
||
|
K-120x80 |
500-800/5(1) |
||
|
1000-1200/5(1) |
5 |
||
|
1250-1500/5(1) |
|||
|
K-130x40 |
1000-2000/5(1) |
10 |
|
|
2500-5000/5(1) |
10 |
||
|
K-130x60 |
1000-2000/5(1) |
10 |
|
|
2500-6000/5(1) |
15 |
||
|
K-140x60 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-160x80 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-200x80 |
1000-2000/5(1) |
10 |
|
|
2500-3000/5(1) |
10 |
||
|
4000-5000/5(1) |
15 |
||
|
K-Φ20 |
100A/20mA |
1 |
15Ω |
|
K-Φ30 |
200A/20mA |
10Ω |
|
|
K-Φ30 |
300A/20mA |
10Ω |
AKH-0.66/K Series Split Type Measure Current TransformersDiagram
Hold the lower section firmly at the direction of arrow
Loosen two screws at the direction of arrow and remove them
Separate the lower section at the direction of arrow
Mount the copper bar and assemble the lower section at the direction of arrow
Hold it firmly at the direction of arrow
Hold the lower section firmly at the direction arrow, insert two screws and tighten nuts
Fix the copperbar with M5screwsand pressure plates
AKH-0.66/K Series SCT Current Transformers Uses
Our flexible split core current transformers are effectively used in reconstructing projects of urban
Split core current transformers are suitable for rural power grids to reconstruct
Split Current TransformerInstallation
Press the arrow direction firmly to open the two screws and press the lower part
Unscrew and pull out the two screws in the direction of the arrow, see "P2"
Pull the screw and pull out the lower part in the direction of the arrow
After installing on the copper busbar, close the lower part in the direction of the arrow, see "P4"
Press firmly in the direction of the arrow
Press the lower part firmly and press the arrow direction to insert the two screws into the holes and tighten the screw width, see "P6"
Then use MS screws and pressure plate to install and press the steel row according to "P6"
As one of split core current transformer manufacturers, we will do our best to meet all the needs of customers.
Send product request
Other supplier products
| ISOLATED POWER SYSTEMS | Acrel wireless theft monitoring systemare mainly used in the medical and industrial sectors. The medical IT system is mainly designed for the large... | |
| ACREL AMC SERIES DATA CENTER MONITOR MODULE | Acrel data center power distribution system solution is to improve the power efficiency of the data center and reduce the energy consumption of equ... | |
| POWER SENSOR | Acrel power sensor is designed for industrial electrical measurement of low voltage system, include high precision current transformer, hall effect... | |
| ACREL AID150 ALARM AND DISPLAY DEVICE | The AID150 insulation monitoring device schneideris designed for visual and audible indication of alarm messages from ACREL medical intelligent ins... | |
| AKH-0.66 / K Split Core Current Transformer | Acrel AKH-0.66/K series split core current transformerare mainly used in reconstructing projects of urban and rural power grids. The split core cur... |
Same products
| Onboard Multi-Network Router | Seller: ZHUHAI ZTLX NETWORK TECHNOLOGY CO.,LTD | Onboard Multi-Network Router Reliable Onboard Connectivity for Railway Communication Systems Th... | |
| Onboard Video-on-Demand (VOD) Server | Seller: ZHUHAI ZTLX NETWORK TECHNOLOGY CO.,LTD | Onboard Video-on-Demand (VOD) Server Designed for railway Wi-Fi systems,the ZTDC series video-on... | |
| Onboard Wireless Access Point(AP) | Seller: ZHUHAI ZTLX NETWORK TECHNOLOGY CO.,LTD | Onboard Wireless Access Point(AP) Onboard Wireless Access Point (AP)for Railway Passenger Servic... | |
| Onboard 5G Multi-Network Router | Seller: ZHUHAI ZTLX NETWORK TECHNOLOGY CO.,LTD | Onboard 5G Multi-Network Router Onboard 5G Router for Railway Onboard Communication Systems Hig... | |
| Onboard 4G Multi-Network Router | Seller: ZHUHAI ZTLX NETWORK TECHNOLOGY CO.,LTD | Onboard 4G Multi-Network Router Onboard 4G Router for Railway Onboard Communication Systems The... |













