ACREL AM3SE 3 PHASE MV SWITCHGEAR CURRENT VOLTAGE PROTECTION RELAY
ACREL AM3SE 3 PHASE MV SWITCHGEAR CURRENT VOLTAGE PROTECTION RELAY
AM3SE 3 phase under current relayincludes power supply module, CPU module, input and output module, control loop module, analog quantity acquisition, communication module, etc., which adopts modular design and has strong versatility. It can carry out protection function design for different objects on the same hardware platform, and realize power system protection with voltage level of 35kV and below.It is suitable for the protection and automatic control functions of incoming lines, feeders, main transformers (generally above 2000kVA), distribution transformers (generally below 2000kVA), high-voltage motors, high-voltage capacitors, bus tie, PT and other equipment.
Specifications of AM3SE 3 Phase Mv Switchgear Current Voltage Protection Relay
|
AM3SE |
||
|
Protection functions |
I |
U |
|
Overcurrent (3 stages,IDMT) |
■ |
|
|
Earth fault (3 stages,IDMT)(I01/I02) |
■ |
|
|
Negative sequence overcurrent (2 stages,IDMT) |
■ |
|
|
Auto-reclose |
■ |
|
|
Overload (trip/alarm) |
■ |
|
|
Under frequency |
■ |
|
|
Post-accelerated overcurrent |
■ |
|
|
Post-accelerated overcurrent(I01/I02) |
■ |
|
|
Overvoltage(trip) |
■ |
|
|
Undervoltage (trip) |
■ |
|
|
Self-produced over zero-voltage (trip) |
■ |
|
|
Residual overvoltage (trip) |
■ |
|
|
FC block |
■ |
|
|
Trip and close circuit supervision (alarm) |
■ |
|
|
Non-electricity (trip/alarm) |
■ |
|
|
Undervoltage (alarm) |
■ |
■ |
|
Overvoltage (alarm) |
■ |
■ |
|
Residual overvoltage (alarm) |
■ |
■ |
|
PT supervision (alarm) |
■ |
■ |
|
Self-produced over zero-voltage (alarm) |
■ |
|
|
Rear ports |
I |
U |
|
RS485 |
■ |
|
|
Protocols |
I |
U |
|
Modbus serial |
■ |
|
|
IEC |
■ |
|
|
Measurement |
I |
U |
|
Electric parameter |
U, I, P, Q, PF, Fr, Ep, Eq, Es |
|
|
Input Current |
5 |
0 |
|
Input Voltage |
3 |
3 |
|
Logs and Records |
I |
U |
|
Fault recorder |
■ |
|
|
Sequence of event record |
■ |
|
|
Monitoring Functions |
I |
U |
|
Anti-pumping circuit |
Optional |
|
|
Remote control |
■ |
|
Features of AM3SE 3 Phase Mv Switchgear Current Voltage Protection Relay
01
It provides B-channel AC input (standard hardware includes: three-phase protection current, two zero-sequence current and 3 voltage channels), 11 user-defined active switch inputs, and 5 programmable passive switch inputs output.
02
The working power supply supports AC/DC 220V, AC/DC 110V self-adaptation or DC 24V, DC 48V self-adaptation.
03
The external anti-jump module (can be installed on the standard guide rail), is more convenient to use with various switchgears.
04
It adopts 32-bit CPU with high performance and low power consumption, which has excellent processing ability and real-time response performance, ensuring that the CPU load rate is only less than 30% when the device is running normally.
05
It has a huge information record, including: more than 200 S0E messages, system information, and fault recording data of more than 10 seconds in total. Wave recording data includes 8 communication channels and 11 remote signaling information.
06
It provides 1 RS485 serial communication interface,and supports IEC .Besides, Modbus communication protocol is optional.
07
It provides GPS time synchronization interface and supports IRIG-B time synchronization method.
If you want to know more about 3 phase monitoring relay phase loss under voltage over voltage, please visit our website.
As a power meter manufacturer, we will do our best to meet all the needs of customers.
在线联系供应商
Other supplier products
| ACREL AM3SE 3 PHASE MV SWITCHGEAR CURRENT VOLTAGE PROTECTION RELAY | ACREL AM3SE 3 PHASE MV SWITCHGEAR CURRENT VOLTAGE PROTECTION RELAY AM3SE 3 phase under current relayincludes power supply module, CPU module, inpu... | |
| ACREL AMC72-DV DC VOLT METER | ACREL AMC72-DV DC VOLT METER AMC72-DV small dc voltmeteris often used in DC motor drive circuits, battery charging circuits, battery testing, etc.... | |
| ACREL AMC72L-AI3 PROGRAMMABLE AC CURRENT METER | ACREL AMC72L-AI3 PROGRAMMABLE AC CURRENT METER Acrel's Programmable digital ac current meter- AMC72L-AI3. Measure three-phase AC current with LCD ... | |
| ACREL AM5SE MIDDLE VOLTAGE SWITCHGEAR PROTECTION RELAY | ACREL AM5SE MIDDLE VOLTAGE SWITCHGEAR PROTECTION RELAY This Switched Ground Relay provides accurate and efficient protection for your switchgear s... | |
| ACREL AMC16-DETT BASE STATION DC ENERGY METER FOR TELECOM TOWER | ACREL AMC16-DETT BASE STATION DC ENERGY METER FOR TELECOM TOWER AMC16-DETT base station DC energy meter For telecom-tower is mainly designed for b... |
Same products
| Amorphous Alloy Type Transformer Iron Core | 卖方: Shijiazhuang Tianya Electric Co., LTD | Amorphous Alloy Type Transformer Iron Core -The iron coreis made of high magnetic conductivity m... | |
| 10kv Dry Type Epoxy Resin Cast Power Transformer | 卖方: Shijiazhuang Tianya Electric Co., LTD | 10kv Dry Type Epoxy Resin Cast Power Transformer Epoxy resin cast dry-type transformeris a high-... | |
| HM B200/B210 Series | 卖方: BEIJING HIGHMESH INFORMATION TECHNOLOGY CO.,LTD. | HM B200/B210 Series USRP B200/B210 Product Overview The B200 and B210 hardwarecovers RF frequen... | |
| HM-B210(Single-Board) | 卖方: BEIJING HIGHMESH INFORMATION TECHNOLOGY CO.,LTD. | HM-B210(Single-Board) Description TheB210is a highly integrated Universal Software Radio Periph... | |
| Busbar systems | 卖方: Jinan Dema Electric Co., Ltd. | Busbar systems Busbar Systems for Plant Reliable Industrial Power Distribution Solutions for Fa... |