ACREL AM3SE 3 PHASE MV SWITCHGEAR CURRENT VOLTAGE PROTECTION RELAY
ACREL AM3SE 3 PHASE MV SWITCHGEAR CURRENT VOLTAGE PROTECTION RELAY
AM3SE 3 phase under current relayincludes power supply module, CPU module, input and output module, control loop module, analog quantity acquisition, communication module, etc., which adopts modular design and has strong versatility. It can carry out protection function design for different objects on the same hardware platform, and realize power system protection with voltage level of 35kV and below.It is suitable for the protection and automatic control functions of incoming lines, feeders, main transformers (generally above 2000kVA), distribution transformers (generally below 2000kVA), high-voltage motors, high-voltage capacitors, bus tie, PT and other equipment.
Specifications of AM3SE 3 Phase Mv Switchgear Current Voltage Protection Relay
|
AM3SE |
||
|
Protection functions |
I |
U |
|
Overcurrent (3 stages,IDMT) |
■ |
|
|
Earth fault (3 stages,IDMT)(I01/I02) |
■ |
|
|
Negative sequence overcurrent (2 stages,IDMT) |
■ |
|
|
Auto-reclose |
■ |
|
|
Overload (trip/alarm) |
■ |
|
|
Under frequency |
■ |
|
|
Post-accelerated overcurrent |
■ |
|
|
Post-accelerated overcurrent(I01/I02) |
■ |
|
|
Overvoltage(trip) |
■ |
|
|
Undervoltage (trip) |
■ |
|
|
Self-produced over zero-voltage (trip) |
■ |
|
|
Residual overvoltage (trip) |
■ |
|
|
FC block |
■ |
|
|
Trip and close circuit supervision (alarm) |
■ |
|
|
Non-electricity (trip/alarm) |
■ |
|
|
Undervoltage (alarm) |
■ |
■ |
|
Overvoltage (alarm) |
■ |
■ |
|
Residual overvoltage (alarm) |
■ |
■ |
|
PT supervision (alarm) |
■ |
■ |
|
Self-produced over zero-voltage (alarm) |
■ |
|
|
Rear ports |
I |
U |
|
RS485 |
■ |
|
|
Protocols |
I |
U |
|
Modbus serial |
■ |
|
|
IEC |
■ |
|
|
Measurement |
I |
U |
|
Electric parameter |
U, I, P, Q, PF, Fr, Ep, Eq, Es |
|
|
Input Current |
5 |
0 |
|
Input Voltage |
3 |
3 |
|
Logs and Records |
I |
U |
|
Fault recorder |
■ |
|
|
Sequence of event record |
■ |
|
|
Monitoring Functions |
I |
U |
|
Anti-pumping circuit |
Optional |
|
|
Remote control |
■ |
|
Features of AM3SE 3 Phase Mv Switchgear Current Voltage Protection Relay
01
It provides B-channel AC input (standard hardware includes: three-phase protection current, two zero-sequence current and 3 voltage channels), 11 user-defined active switch inputs, and 5 programmable passive switch inputs output.
02
The working power supply supports AC/DC 220V, AC/DC 110V self-adaptation or DC 24V, DC 48V self-adaptation.
03
The external anti-jump module (can be installed on the standard guide rail), is more convenient to use with various switchgears.
04
It adopts 32-bit CPU with high performance and low power consumption, which has excellent processing ability and real-time response performance, ensuring that the CPU load rate is only less than 30% when the device is running normally.
05
It has a huge information record, including: more than 200 S0E messages, system information, and fault recording data of more than 10 seconds in total. Wave recording data includes 8 communication channels and 11 remote signaling information.
06
It provides 1 RS485 serial communication interface,and supports IEC .Besides, Modbus communication protocol is optional.
07
It provides GPS time synchronization interface and supports IRIG-B time synchronization method.
If you want to know more about 3 phase monitoring relay phase loss under voltage over voltage, please visit our website.
As a power meter manufacturer, we will do our best to meet all the needs of customers.
在线联系供应商
Other supplier products
| ACREL AKH-0.66/P PROTECTION CURRENT TRANSFORMER | ACREL AKH-0.66/P PROTECTION CURRENT TRANSFORMER AKH-0.66/P protection ct and metering cttransformer is mainly suitable for the relay protection ci... | |
| ACREL AHKC-EKA OPEN-LOOP HALL EFFECT TRANSDUCER (SPLIT-CORE) | ACREL AHKC-EKA OPEN-LOOP HALL EFFECT TRANSDUCER (SPLIT-CORE) AHKC-EKA series open-type Hall current sensor is a new generation of current sensor d... | |
| ACREL ADL200 SINGLE PHASE ELECTRIC METER WITH MODBUS | Single-phase electronic energy meter AcrelADL200is mainly used to measure single-phase active energy of low-voltage network, and can measure voltag... | |
| ACREL ACR10R-DXXTEX BIDIRECTIONAL THREE-PHASE REFLUX MONITORING ENERGY METER | ACR10R-DxxTEx bidirectional three-phase re-flux monitoring energy meter is equipped with external Rogowski coils and split-type transformers, which... | |
| AGF-AE SERIES PV/SOLAR INVERTER ENERGY METER | AGF-AE Series PV/Solar Inverter Meter, as the key components of anti-backflow detection, adopts high-performance MCU and high-precision metering ch... |
Same products
| Lightweight Liquid-cooled LED Module 300W | 卖方: Shenzhen Getian Opto-electronics Co., Ltd. | Lightweight Liquid-cooled LED Module 300W Product Description Lightweight Liquid-cooledLED Modu... | |
| 600W Liquid Cooled LED Module | 卖方: Shenzhen Getian Opto-electronics Co., Ltd. | 600W Liquid Cooled LED Module Getian’s600W Liquid CooledLED Moduleis designed for high-pow... | |
| Liquid-cooled LED Module | 卖方: Shenzhen Getian Opto-electronics Co., Ltd. | Liquid-cooled LED Module Getian’sLiquid Cooled LED Modulesare designed to deliver stable p... | |
| High-purity silica nano powder | 卖方: Hebei Guiyan Electronic Materials CO., Ltd | High-purity silica nano powder High-purity silica nanopowderis a nano-silica powder prepared via... | |
| High purity organic colloidal Silica | 卖方: Hebei Guiyan Electronic Materials CO., Ltd | High purity organic colloidal Silica High-purity organic silica solis manufactured from high-pur... |