SF6 Gas 11 KV Load Break Switch
SF6 Gas 11 KV Load Break Switch
The 11kv load break switchis suitable for the distribution network with the highest voltage 11kV, the rated current 630A, and the rated frequency 50/60Hz, which can break off and close the load current and overload current in the power system. The 11 KV LBS is equipped with an intelligent controller to realize the automation of the distribution system. Inquiry 11kv load break switch price.
SF6 Gas 11 KV Load Break SwitchFeatures
The operating mechanism with spring energy storage ensures fast closing and switching operation (<1000ms).
Operator place: Local/Remote.
11KV LBSequipped with an electronic controller, this sf6 load break switch can be operated locally or with FTU/RTU interface for console operation.
SF6 Gas 11 kv Load Break Switch In Pole Mounted Switch Solution
The type of high-voltage bypass type SF6 11KV LBS insulated load switch is divided into manual type and electric type, which is an engineering bypass type load switch used for the maintenance and construction of power distribution cabinet in order to make uninterrupted power supply to distribution lines. This 11kv load break switch utilizes SF6 gas, known for its outstanding insulation and arc extinguishing performance. Inquiry 11kv load break switch price. Check more pole top switches.
SF6 Gas 11KV Load Break Switch PDF Specification
Parameter Name |
Unit |
Technical Requirement |
Rated Maximum Voltage |
kV |
12 |
Rated continuous Current |
A |
630 |
Short Time Withstand Current |
kA |
20 |
Short-circuit Making Current (peak) |
kA |
50 |
Power Operating Time (Close/Open) |
sec |
<2 |
Mechanical Operations |
times |
3000 |
Rated full load operations |
times |
400 |
Breaking Capacity |
||
Main Active (0.7pf) |
A |
630 |
Cable charging |
A |
5 |
Transformer magnetizing |
A |
10 |
Lightning Impulse Withstand Level |
||
Phase to Earth |
kV |
75 |
Across interrupter |
kV |
85 |
Power Frequency withstand voltage |
||
Phase to Earth |
kV |
42 |
Across interrupter |
kV |
50 |
Other Ratings & Specifications |
||
Creepage Distance (Silicon) |
mm |
830 |
IP Level |
65 |
|
Arc Extinction Medium |
SF6 Gas |
|
Insulation Medium |
SF6 Gas |
|
Leakage Rate |
cc/ sec |
≤0.5% |
Product size (max) |
||
Width |
mm/in |
1368/54 |
Height |
mm/in |
530/21 |
Environmental Conditions for Equipment Use of SF6 Gas 11KV Load Break Switch
Environmental conditions for equipment use |
height above sea level:≤3000m |
Air temperature: -40℃~+50℃ |
Maximum diurnal temperature difference:≤25℃ |
Relative humidity:Daily mean95% monthly average90% |
Maximum wind speed:≤34m/s |
Earthquake intensity:<8 degree |
Icing thickness: <10mm |
Thickness of snow: <35mm |
irradiance: <0.1W/cm2 |
Pollution grade: Ⅲ class, Ⅳ class Ⅲ, Ⅳ |
Installation site: No fire disaster, explosion danger, chemical corrosion, and frequent strenuous vibration places |
11 KV Load Break Switch Working Procedure
The 11KV LBS load switch that uses SF6 gas as insulation and arc extinguishing medium is called the SF6 gas load break switch. It can be used to switch and switch load current and overload current, and it can also be used to switch and switch no-load circuits, no-load transformers, and capacitors and outdoor pole mounted load break switch groups, among others. All three-position load switches with the functions of connecting, disconnecting, and grounding have the characteristics of simple structure and low price. But the load switch cannot disconnect the short-circuit current.
Intended Use of SF6 Gas 11KV Load Break Switch
The 11KVSF6 LBSload switch is an excellent load switch that many users have experienced in recent years. In addition to its long electrical life and strong braking force, it has the same advantages as the vacuum load switch. Its outstanding advantage is that it is easy to achieve three working positions (connected, disconnection and grounding), small current (inductance, capacitance) breaking, strong resistance to severe environmental conditions. It is suitable for popularization and application in urban and rural medium voltage distribution networks.
As an electric power equipment company, we will do our best to meet all the needs of customers.
在线联系供应商
Other supplier products
11KV Auto Recloser Vacuum Circuit Breaker | ZW32 series 11 kv breakerare used in distribution systems. 11kv auto reclosers are used to make and break normal and fault currents. 11kv outdoor c... | |
Centralized Type DTU | Centralized Type DTU The centralized DTU adopts high-performance MCU processor, high-speed industrial network communication technology, multi-CPU ... | |
Centralized Type DTU | Centralized Type DTU The centralized DTU adopts high-performance MCU processor, high-speed industrial network communication technology, multi-CPU ... | |
SCADA Remote Terminal Unit RTU | As one of the top SCADA RTU manufacturers,Remote terminal unit scada is a general term for various remote monitoring installed in the distribution ... | |
15KV SF6 Gas Load Break Switch | 15KV SF6 Gas Load Break Switch 15kv load break switchis suitable for rated voltage 15kV, rated current 630A, 50/60Hz distribution network breaking... |
Same products
Vertiv Emerson GXE2 1-10KVA UPS | 卖方: Hebei Kelingyizhi Communication Technology Co., Ltd | This series of Vertiv Emerson GXE2 1-10KVA UPShas the following characteristics: Compared with t... | |
vertiv Liebert GXE 1kva tower type ups | 卖方: Hebei Kelingyizhi Communication Technology Co., Ltd | Vertiv Liebertseries UPSis a new generation of tower, single input, single output, online high-pe... | |
SCHNEIDER discrete input module 140DDI35300 | 卖方: 840499 | Range of Product Modicon Quantum automation platform Product or Component TypeLow voltage dc disc... | |
Fuji Electric FRN5.5VG1S-4 powder inverter | 卖方: 840499 | 技术规格制造商:富士电机系列:FRENIC-VG型号:FRN5.5VG1S-4E应用:泵/风扇/升降机/起重机/通用容量,kW:5.5电流,А:13.5主电源,V:380-480 50 Hz/6... | |
JCID iBooter Current Analyzer One-key Boot iPhone 7-16 Series | 卖方: Phonefix | JCID Intelligent Drawing Current Analyzer - iBooter, a powerful current analyzer voltage monitor ... |