TXJQ3 Electrical Isolation Switch
Scope of Application
TXJQ3 Electrical Isolation Switch is used for AC 50 / 60Hz, rated voltage 230-400V , 63A to 125A of rated current in the resistance and inductive hybrid circuit, mainly for on or off in the no load conditions to connect or isolate line and power. Especially it is used for isolating the power supply effectively to prevent accidental switch-on when people check circuit , in order to ensure operational safety of maintainer, electrical isolator switch is widely used in the matching products of national agricultural network meter box and replaces the old knife switch, the installation is more convenient , appearance is more beautiful.
Use environment and working conditions
◆ Ambient air temperature: -5 ℃ ~ +40 ℃, the average temperature does not exceed +35 ℃.
◆ Altitude: not more than 2000m.
◆ Relative temperature of atmosphere: +40℃ is not more than 50%, the wettest month is 90%.
◆ Pollution Degree: Grade Ⅱ.
◆ Use category: AC-22A.
◆ Installation conditions: hand-pull disconnector is normally installed vertically (top of the line), the handle pushed up, contact connected: play down the contact is disconnected, then the handle can be buckled to avoid accidental closing.
◆ Installation adopt TH35-7.5 type DIN rail.
Main technical parameters
Rated Current (A): 32, 63, 100
Pole: 1P, 2P, 3P, 4P
Rated working voltage: single-phase 230V, Three-phase 400V
Rated short-time withstand current: 12Ie, power-on time is 1s
Rated short-time making capacity: 20Ie, power-on time is 0.1s
Rated making and breaking capacity: 3Ie,1.05Ue,cosφ=0.65
operating performance: No-load 8500 times, On-load 1500times, In total 10000 times
Other supplier products
|
DW45 Air Circuit Breaker |
Scope of applicationDW45 Air Circuit Breaker, ACB (hereinafter referred to as circuit breaker) is suitable for distribution network with AC 50Hz, r... |
|
Fiber Termination Box |
Product overview TXPZ2 Fiber Termination Box is the result of the development of information technology and popularization of fiber-optic technolog... |
|
HG2B In-line Fuse Switch Disconnector |
Scope of application HG2B In-line Fuse Switch Disconnector is suitable for AC rated voltage 660V and below, AC 160A~630A, rated AC frequency 50Hz. ... |
|
TNID Residual Current Circuit Breaker |
Scope of ApplicationTNID-63 Residual Current Circuit Breaker is used for the circuit of AC 50Hz, rated voltage of 230V for 2 poles, 400V for 4 pole... |
|
DZ30-32 Miniature Circuit Breaker |
Scope of application DZ30-32 Miniature Circuit Breakers (DPN) are designed for single-phase residential circuits of AC 50Hz or 60Hz, rated voltages... |
供应产品
Same products