CT PT analyzer HYVA-404
|
Tests for Current Transformer: Tests for Voltage Transformer: 1)Turns ratio test and phase angle error test |
| 1) CT nameplate check 2) CT parameters check in work burden 3) CT transient parameters analysis 4) CT ratio and phase error calibration 5) PT routine test |
| 1 Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13 2 Power supply: AC220V±10%,50Hz/60Hz±10% 3 Power output: 0.1~180V (AC) 4 Current output: 0.001~5A(RMS) 5 Power output:300VA 6 Maximum knee voltage measurement:45kv 7 Current measurement: Range:0~10A (automatically change range in 0.1/0.4/2/10A) Error <±0.1%+0.01%FS 8 Voltage measurement: Range:0~200 V (automatically change range in 1V/10V/70V/200V) Error < ±0.1%+0.01%FS 9 Turns ratio measurement: Range :1~35000, 1~2000 error<0.05% 2000~5000 error>0.1% 5000~35000 error<0.2% 10 Phase measurement: error:±2min,resolution:0.01min 11 Coil resistance measurement: Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) Error< 0.2%RDG+0.02%FS Maximum resolution:0.1mΩ 12 Temperature measurement:-50~100 Celsius degree, error<3 Celsius degree 13 CT Secondary burden: Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) Error <0.2%RDG+0.02%FS Maximum resolution 0.001ohm 14 PT Secondary burden: Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) Error <0.2%RDG+0.02%FS Maximum resolution: 0.1ohm 15 PT ratio measurement: Range :1~35000, 1~5000 error<0.2% 5000~35000 error<0.5% 16 Saved data groups:>1000groups 17 Work condition: Temperature:-10℃~50℃, moist:≤90% 18 Size: 485mm×356mm×183mm 19 Weight: <15Kg |
在线联系供应商
Other supplier products
| HYYJ-502A Insulating oil tester | Portable dielectric oil tester technical index: (1) AC220V±10% power supply input (2) Output voltage:AC 0V~100KV (3) Rate of voltag... | |
| ZGF DC High Voltage Generator | ZGF DC high voltage generator is DC high voltage power supply equipment which is applied in power cable test and arrester test in power system. ... | |
| HYYJ-501 insulating oil tester | Dielectric oil tester functions: 1 Breakdown test of user-defined2 Proof test3 Calibration interface for customers4 Uploading data to PC and making... | |
| HYBC-901 Transformer Ratio Meter | Transformer ratio meter Itistotestvoltageratio,vector,polarity,ratioerrorofcurrenttransformerandvoltagetransformer. Transformer turns ratio met... | |
| SLQ Primary Current Injection Test Set | Introduction: SLQ primary current injection test setis a high current generator instrument. It is applied in current transformer test, circuit bre... |
Same products
| JXF Distribution Box | 卖方: Jiangsu Aokai Electric Co., Ltd | JXF Distribution Boxis a modular distribution box with advanced technology and performance introd... | |
| XL Power Distribution Switchgear | 卖方: Jiangsu Aokai Electric Co., Ltd | XL-21 power distribution boxis suitable for ac 50 (60) HZ, voltage to 690V, power supply system, ... | |
| Common Rail Injector Nozzle 880P119092 | 卖方: China lutong | Common Rail Injector Nozzle 880P119092 Common Rail Injector Nozzle A6510702887Chris Whats/ app:+... | |
| Bently Nevada AC Power Supply PN 127610-01 of 3500/15 | 卖方: 840499 | 3500/15 127610-01 | Bently Nevada | 3500/15 交流电源模块(停产。新替代品:106M1079-01:通用交流电源模块)3500/15 127610-01... | |
| 隧道专用箱变 | 卖方: 839459 | 隧道专用箱变是针对在隧道环境中使用而专门设计的产品,针对隧道内湿度大,运行空间狭小等特殊性,该产品采用全密封双层隔温分体式箱体,配备凝露控制器与温度控制器,实现实时监控与自启动的功能,有效保证隧... |