CT PT analyzer HYVA-404
Tests for Current Transformer: Tests for Voltage Transformer: 1)Turns ratio test and phase angle error test |
1) CT nameplate check 2) CT parameters check in work burden 3) CT transient parameters analysis 4) CT ratio and phase error calibration 5) PT routine test |
1 Test standards: IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13 2 Power supply: AC220V±10%,50Hz/60Hz±10% 3 Power output: 0.1~180V (AC) 4 Current output: 0.001~5A(RMS) 5 Power output:300VA 6 Maximum knee voltage measurement:45kv 7 Current measurement: Range:0~10A (automatically change range in 0.1/0.4/2/10A) Error <±0.1%+0.01%FS 8 Voltage measurement: Range:0~200 V (automatically change range in 1V/10V/70V/200V) Error < ±0.1%+0.01%FS 9 Turns ratio measurement: Range :1~35000, 1~2000 error<0.05% 2000~5000 error>0.1% 5000~35000 error<0.2% 10 Phase measurement: error:±2min,resolution:0.01min 11 Coil resistance measurement: Range:0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/8kohm) Error< 0.2%RDG+0.02%FS Maximum resolution:0.1mΩ 12 Temperature measurement:-50~100 Celsius degree, error<3 Celsius degree 13 CT Secondary burden: Range 0~160ohm (automatically change range in 2ohm/20ohm/80ohm/160ohm) Error <0.2%RDG+0.02%FS Maximum resolution 0.001ohm 14 PT Secondary burden: Range 0~80kohm (automatically change range in 800ohm/8kohm/80kohm) Error <0.2%RDG+0.02%FS Maximum resolution: 0.1ohm 15 PT ratio measurement: Range :1~35000, 1~5000 error<0.2% 5000~35000 error<0.5% 16 Saved data groups:>1000groups 17 Work condition: Temperature:-10℃~50℃, moist:≤90% 18 Size: 485mm×356mm×183mm 19 Weight: <15Kg |
Send product request
Other supplier products
YJJ-ⅡInsulating Oil Tester | Dielectric oil tester functions: 1 Breakdown test of user-defined2 Proof test3 Calibration interface for customers4 Result print Insulating oil tes... | |
FRC series High Voltage Divider | Application FRC series high voltage divider is applied to measure AC/DC high voltage in metrology department of power system or high voltage test.... | |
ct pt analyzer HYVA-405 | Introduction Tests for Current Transformer: 1 Excitation curve and parameters test2 Turns ratio test3 Ratio and phase error test4 Polarity mar... | |
Primary current injection tester | Introduction: HYPCIT series primary current injection tester is applied in power system for circuit breaker test, protection system test and curr... | |
HYGK-303 Circuit Breaker Analyzer | Circuit breakeranalyzergeneralintroduction: ThiscircuitbreakertesterisworkingonIEC62771, thecircuitbreakeranalyzerhasanaccuratedisplayscreenandrota... |
Same products
Bently Nevada AC Power Supply PN 127610-01 of 3500/15 | Seller: 840499 | 3500/15 127610-01 | Bently Nevada | 3500/15 交流电源模块(停产。新替代品:106M1079-01:通用交流电源模块)3500/15 127610-01... | |
Tunnel special box transformer | Seller: 839459 | Tunnel special box transformer is a product specially designed for use in the tunnel environment.... | |
AC Metal Аrmored Movable Switchgear 35KV KYN40.5 in-hous | Seller: 839459 | KYN61-40.5 armored movable AC metal enclosed switchgear is suitable for three-phase AC 50Hz power... | |
Аctive Filter Cabinet | Seller: 839459 | Аctive filter: сollaborating with well-known component manufacturers in the industry to provide h... | |
SVG | Seller: 839459 | SVG: ensuring electricity safety, passing national testing standard. |