HYPCIT Primary current injection tester
Introduction:
HYPCIT series primary current injection tester is applied in power system for circuit breaker test, protection system test and current transformer test. The current injection tester generates a high current from power supply to simulate the rated current or fault current in the primary circuit of power equipment.
Applications:
1)High current output injected to the main circuit of power line to simulate the fault current. And then check whether the protection system will be operated according to the design
2) High current output injected to the primary of current transformer and then measure the inducted current from secondary by error measurement instrument to check the ratio error and phase displacement of CT
3)High current output injected to the main circuit of circuit breaker to simulate the rated current in primary. And then check the stability of circuit breaker according to the temperature rise procedure.
4)Considered as a AC high current source in power equipment or cable test.
Primary current injection tester technical index:
1 Power supply: AC220V or AC 400V, 45Hz~65Hz. The power supply voltage is depends on the power output capacity. Detail information is as table 1.
2 Typical output current: 500A or 1000A or 2000A
Typical output capacity 3KVA or 5KVA or10KVA or15KVA
It can be customized according to your requirements from above specs
3 Impendence voltage: 8%
4 Idle current: 6%
5 Current distortion <5%
6 Current is measured from the secondary of current transformer which is installed in the internal of the current booster. The display unit is 4 and 1/2 digitals current meter. Maximum measurement error 0.5%RDG+5D.
7 Timer indication of test running is an optional configuration. The timer could be customized according to the requirement of customer from the follow list:
1) 4 digital timer from 0~9999s / 0~999.9s /0~99.99s, accuracy 0.5%RDG+5D
2) 5 digital timer from 0~99999s / 0~9999.9s /0~999.99s, accuracy 0.2%RDG+2D
3) 6 digital timer from 0~999999s / 0~99999.9s /0~9999.99s, accuracy 0.1%RDG+1D
8 work temperature:0~40 C, Humidity <90%
Model |
Output Current (A) |
Capacity (KVA) |
Output Voltage (V) |
3/500 |
500 |
3 |
6 |
5/500 |
500 |
5 |
10 |
10/500 |
500 |
10 |
20 |
15/500 |
500 |
15 |
30 |
3/1000 |
1000 |
3 |
3 |
5/1000 |
1000 |
5 |
5 |
10/1000 |
1000 |
10 |
10 |
15/1000 |
1000 |
15 |
15 |
3/2000 |
2000 |
3 |
1.5 |
5/2000 |
2000 |
5 |
2.5 |
10/2000 |
2000 |
10 |
5 |
15/2000 |
2000 |
15 |
7.5 |
Email
Miss Chloe Wang
在线联系供应商
Other supplier products
供应产品
HYGK-303 Circuit Breaker Analyzer
Circuit breakeranalyzergeneralintroduction:
ThiscircuitbreakertesterisworkingonIEC62771,
thecircuitbreakeranalyzerhasanaccuratedisplayscreenandrota...
HYEC-10 digital radio phase detectors
1.Display:phase angle, frequency, voltage waveform 2.Bring Rechargeable Battery 3.Patented product, Simple maintenance 4.Acquisition of signal i...
CT PT analyzer HYVA-404
Introduction
Tests for Current Transformer:1)Excitation curve and parameters test2)Turns ratio test3)Ratio and phase error test4)Polarity mark...
HYPCIT Primary current injection tester
Introduction:
HYPCIT series primary current injection tester is applied in power system for circuit breaker test, protection system test and curre...
HYKC-2000 On Load Tap Changer Ohmmeter Analyzer
1.Introduction On load tap changer analyzer HYKC-2000 is mainly applied to test transient time, transition waveform, transition resistance, sync...
Same products
Bently Nevada AC Power Supply PN 127610-01 of 3500/15
卖方: 840499
3500/15 127610-01 | Bently Nevada | 3500/15 交流电源模块(停产。新替代品:106M1079-01:通用交流电源模块)3500/15 127610-01...
隧道专用箱变
卖方: 839459
隧道专用箱变是针对在隧道环境中使用而专门设计的产品,针对隧道内湿度大,运行空间狭小等特殊性,该产品采用全密封双层隔温分体式箱体,配备凝露控制器与温度控制器,实现实时监控与自启动的功能,有效保证隧...
交流金属铠装移开式开关设备
卖方: 839459
KYN61-40.5铠装移开式交流金属封闭开关设备适应于三相交流50Hz电力系统,用于发电厂,变电所及工矿企业的配电室接受和分配电能之用,并对电路实行控制、保护及监测。 使用环境 ►环境温度:最...
有源滤波柜
卖方: 839459
有源滤波:与业内知名元器件厂家合作,为电力节能及谐波治理提供优质解决方案
直流屏
卖方: 839459
SVG:通过国家检验标准,为用电安全做保障。