Powtech PT200 variable frequency inverter
Power | |
Voltage and frequency level |
Single-phase 200-240V,50/60HZThree-phase 220-240V,50/60HZ Three-phase 380-415V,50/60HZThree-phase 440-460V,50/60HZ Three-phase 575V,50/60HZThree-phase 660V,50/60HZ Three-phase 1140V,50/60HZ |
Allowable fluctuations |
voltage:+-15% frequency:+-15% |
Controlperformance | |
Control system | DSP-based high-performance vector control inverter |
Output frequency | G/P/Z/S/T/M type: 0.00-400Hz, the maximum frequency could be set on the range of 10.00Hz-400Hz |
Control method | V/Fcontrol, open-loop magnetic flux vector control 1,open-loop magnetic flux vector control 2,PG vector control |
Automatic torque boosting function |
low frequency(1Hz)powerful output torque can be achieved under the V/F controlling |
Accelerate/decelerate control | Segment S curve acceleration and deceleration set mode,maximum running time is 9600 hours |
Program-runing control | 16 segments speed running,maximum running time is 888.88 hours |
Frequency setting accuracy |
Digit:0.01Hz(below 300Hz),0.1Hz(above 300Hz);analogue:1% of maximum frequency |
Frequency accuracy | Speed control tolerance 0.01%((25℃±10℃)) |
V/F curve mode | Linear,square root,user-definition set V/F Cruve |
Over load capability |
G/S type:rated current 150%-1minute,200% of rated current-0.1 second P type: rated current 120%-1minute,150% of rated current-0.1 second Z/M/T: rated current 180%-1minute,150% of rated current-0.1 second H type:rated current 250%-1minute,300% of rated current-0.1 second |
Slip compensation | 50%-100%,automatically compensate for deterioration |
Maximum frequency | 400Hz |
Carrier frequency | 0.5K-15KHZ. According to the load characteristics, automatically adjust the carrier frequency |
Input frequency resolution | Digit setting:0.01Hz Analogue setting: Maximum frequency*0.1% |
Start torque |
G type:0.25Hz/180%P type:0.25Hz/120% |
Adjusting-speed range | 1:200 |
Steady speed accuracy(speed control accuracy) | open-loop magnetic flux vector control:+-0.5%(rated synchronous speed) |
Speed control stability | open-loop magnetic flux vector control:+-0.3%(rated synchronous speed) |
Torque response | ≤40ms(open-loop magnetic flux vector control) |
Torque boost | Automatic torqueboosting;manualtorque boosting0.1%-30% |
Acceleration and deceleration linear | Linear accelerator Mode: four acceleration and deceleration time; Acceleration and deceleration time range 0.0s-3600.0s |
Dc brake |
DC brake frequency:0.0Hz-maximum frequency, braking time:0.0~36.0 second,Braking operation time:0.0%~100 |
Jog control |
Jogging frequency range: 0.00Hz - maximum frequency, jog acceleration and deceleration time: 0.0s-3600.0s |
Multi-segment speed running | achieve up to 16 segment speed run via the control terminal |
Built-in PID | Facilitate the realization of the process control closed-loop control system |
Automatic Voltage Regulato | When the grid voltage changes, automatically maintain a constant output voltage |
Torque limit and control |
Dig-earth machine features, the running torque is automatically limited to prevent frequent over-current trip to rpue control can be achieved under close-loop vector mode |
Personalization features | |
Power-on peripherals,security self-inspected | Afety of the peripherals equipments can be checked when power on,such as grounding,short circuit,etc |
Common DC bus function | The function of multiple inverters share the DC bus |
MF key | Programmable keys: Reversible run/ Jog operation function selection |
Textile pendulum frequency control | Varietyoftriangularwavefrequencycontrol function |
Wave-filter and current-limiting function | Built-in wave-filter and current-limiting calculation method to reduce the frequency reported flow probability, improve the whole anti-jamming capability |
Timing control | Timing control function: to set the time range Oh-65535h |
Keyboard extended cable standardization | Customer can extend the keypad cable with standard cable. |
Input signal | |
Running method | Keyboard/terminal/communication |
Frequency setting |
7 kinds of frequency setting, including adjustable DC 0-10v range, adjuststable DC 0-20mA range, panel potentiometer, etc |
Starting signal | Forward, Reverse |
Multi-segments speed | Up to 16 segments speed can be set(using the multi-function terminal or program run) |
Multi-segments acceleration | up to 4 segments acceleration can be set(using the multi-function terminal) |
Emergency stop | Interrupt controlle output |
Pendulum-frequency running | Process control running |
Jogging | Running slowly |
Fault reset | When the protection function is active, you can automatically or manually reset the fault condition |
PID feedback signal | Including DC 0~10V,DC 1~5V,DC 0~20mA,DC 4~20mA |
Output signal | |
Running status | Motor status display, stop, acceleration and deceleration, constant speed, the program running state |
Fault output | contacting point output AC 250V 5A, DC 30V 5A |
Analogue output |
Two ways analog output, you can select the eight kinds of frequency, current, voltage, temperature and other 8 signals, the output signal range can be set arbitrarily on the range of 0-10V/0-20mA |
Output signal | Up to 3 output signals and there 9 signal for selection. |
Running function | |
Running function | Frequency limit, avoiding frequency ,slip compensation,reverse protection, self-tuning,PID control. |
DC current brake | Built- in PID regulate braking acurrent to ensure adequate braking torque without over current |
Operation command channels |
Three channels: the operation panel set, control terminals set, serial communication port set. Variety of means swiching |
Frequency source |
There are6 kinds of frequency source: digital set, analog voltage set, analog current set,multi segment speed set, a serial port set,PID set,Variety of means switching |
Input terminal |
6digital input terminals, compatible with active PNP or NPN input methods two analog input terminal, which AI1 can only be used as input voltage, AI2 can be as voltage or current input(if it needs to expand input, output terminals function) |
Output termina |
A digital output terminals(dual polarity output) a relay output terminals an analog output terminals, 0/4 mA-20mA or 0/2V-10V is optional, the set frequency ,frequency output, speed and other output of the physical quantities can be achieved. |
Protectionfunction | |
Inverter protection |
Overvoltage protection, undervoltage protection, overcurrent protection, overload protection, over-temperature protection, over the loss of speed protection, over-voltage stall protection, phase protection(optional), external fault, communication error, PID feedback signal abnormalities, PG failure. |
IGBT temperature display | Display present IGBT temperature |
Inverter fan control | The fan starting temperature can be set(optional) |
Instant power-down re-start |
Less than 15 millis seconds: continuous operation. More than 15 milliseconds: Automatic detection of motor speed, instantaneous power-down re-start |
Speed starting tacking method | Inverter automatically track motor speed when inverter starts |
Parameter protection function | Protect inverter parameters by setting the password and decoding |
Display | |
Running information |
There are six operation monitoring objects: set frequency, the actual frequency, the actually motor current, current percentage, DC bus voltage, the output voltage, motor actual speed, accumulative total running time, IGBT temperature, PID set value, PID feedback values, the input terminals state, output terminals state, analog AI1, analog AI2, the current number of segments, torque set value |
Error information |
Up to five error message can be stored, when there is the failure ,the fault type,voltage ,caurrent, frequency and working state can be inqured |
LED display | Display parameter |
OLED display | Optional parts ,Chinese/English display operation content |
Parameter copy | use parameters special kepad can realize the copy of parameters quickly(only for OLED) |
Key lock and function selection | Keypad can be partly or fully locked. Define part of the keys effect scope to avoid faulty operation |
Communication | |
RS485/RS232 | Completely isolated RS485 communication module for the host computer networked communications |
Environment | |
Environment temperature | -10℃~40℃(environmental temperature in the-40℃~50℃, please use decreasing ratio accordingly) |
Store temperature | -20℃~65℃ |
Environment humidity | Less than 90% R.H. no more than 90% R.H |
Height . Vibratio | below 1000m, below 5.9m/S2(=0.6g) |
Application location |
Indoor, and there are no sunlight or corrosive, explosive gas and water vapor, no dust, combustible gas, oil and gas, water vapor, drop of water or salt |
Altitude | Below 1000m |
Pollution level | 2 |
product standards |
|
Product executive safety standards | IEC61800-5-1:2007 |
Product executive EMC standards | IEC61800-3:2005 |
Cooling method | |
Method | Forced air cooling and natural air cooling |
在线联系供应商
Other supplier products
Powtech PT200 variable frequency inverter | Power Voltage and frequency level Single-phase 200-240V,50/60HZThree-phase 220-240V,50/60HZ Three-phase 380-415V,50/60HZThree-ph... |
Same products
Rated Power 2400W 24VDC Solar Inverter | 卖方: Shenzhen BaoEr Energy Technology Co., LTD. | Rated Power 2400W 24VDC Solar Inverter The DC 2.4 kw inverterwith a rated power of 2400 watts is... | |
Rated Power 2400W 24VDC PV Inverter | 卖方: Shenzhen BaoEr Energy Technology Co., LTD. | Rated Power 2400W 24VDC PV Inverter This is a single phase inverter rated at 2400 watts, 24 volt... | |
Rated Power 2400W 24VDC Pure Sine Wave Solar Inverter | 卖方: Shenzhen BaoEr Energy Technology Co., LTD. | Rated Power 2400W 24 Volt Pure Sine Wave Inverter It is a new generation of power inverter with ... | |
Rated Power 2400W 24VDC Off Grid Solar Inverter | 卖方: Shenzhen BaoEr Energy Technology Co., LTD. | Rated Power 2400W 24VDC Off Grid Solar Inverter This is a cost-effective solar inverter that acc... | |
Rated Power 2400W 24VDC Battery Inverter | 卖方: Shenzhen BaoEr Energy Technology Co., LTD. | Rated Power 2400W 24VDC Battery Inverter The Rated Power 2400W 24VDC Battery Inverter is a mid-r... |