Dry Type Hipot Tester
Introduction
HIPOT tester is applied to test the insulation ability of electric power equipments and insulation materials at power frequency high voltage. The insulation test result of the tester is go or not go. Also the HIPOT tester is a universal power source in HV test. The maximum output voltage and capacity could be customized according the requirements of custom.
The tester is consists of single HV transformer and main control box. There are three kinds of HV transformer according to the insulation materials of the HV transformer. They are dry HV transformer,oil HV transformer and SF6 gas HV transformer. For the dry HV transformer the insulation material is epoxy resin. For oil HV transformer the insulation material is insulation oil. For SF6 HV transformer the insulation material is SF6 gas.The dry HV transformer has a smaller size and less weight than oil HV transformer. But the maximum output voltage is less than 100kv for dry HV transformer. The functions of the main control box are voltage output regulation, protection in emergency and voltage/current value indication.
Technique index
1)power supply:
AC 220V 50Hz/60Hz for transformers which the capacity less than 10kva
AC 380V 50Hz/60Hz for transformers which the capacity more than 10kva
2)HV transformer mode: single phase
3)maximum output voltage: 50kv/100kv/150kv/200kv/250kv optional
4)output capacity: 3kva/5kva/10kva/20kva/30kva/50kva/100kva/150kva/200kva optional
5)voltage read mode:analog or digital, direct HV voltage reading form voltmeter
6)current read mode:analog or digital, direct LV circuit current reading from amp meter
7)protection mode: LV circuit over current protection
8)voltage adjust mode: manual regulation
9)Rated frequency: 50Hz/60Hz
10)Automatic zero position lock unit to avoid wrong operation in HV output
11)work temperature: 0~50degree
12)work humidity: <80%
Model selection table
The detail power parameters for the common models HV transformer are as table 1. Please confirm the right model before order. The main parameters include input voltage, maximum output voltage and capacity.
The parameters in this table are response for HV transformer only and we will install the main control box according to the capacity and input voltage of the model you order
Table 1 Parameters for HV transformer
Type |
Capacity KVA |
Low Voltage Input |
High Voltage Output |
No Load Current% |
Impedance Voltage % |
Weight max Kg |
||
Voltage V |
Current |
Voltage KV |
Current mA |
|||||
YD –1.5/50 |
200 |
50 |
30 |
4 |
10 |
22 |
||
YD –3/50 |
3 |
200 |
15 |
50 |
60 |
4 |
10 |
33 |
YD –6/50 |
6 |
200 |
30 |
50 |
120 |
4 |
10 |
53 |
YD –10/50 |
10 |
200 |
50 |
50 |
200 |
4 |
10 |
79 |
YD–10/100 |
10 |
400 |
25 |
100 |
100 |
4 |
10 |
98 |
Notice:
1) If the maximum voltage is less than 100kv we will offer dry HV transformer for the tester, otherwise we will offer oil HV transformer for the tester
2) The capacity and maximum voltage output could be customized according to the requirements of customer if you can not find the right one in this table
3) The weight listed in the table is HV transformer only it does not include the weight of main control box. Please confirm the total weight of the tester with our sales engineer before order
在线联系供应商
Other supplier products
Dry Type Hipot Tester | Introduction HIPOT tester is applied to test the insulation ability of electric power equipments and insulation materials at power frequency high v... | |
Transformer Load and No-load tester HYKF | Measure the transformer load current, load loss, short-circuit voltage, short circuit (load) losses. RMS phase voltage Average value of three-phase... | |
HYKC-2000 On Load Tap Changer Ohmmeter Analyzer | 1.Introduction On load tap changer analyzer HYKC-2000 is mainly applied to test transient time, transition waveform, transition resistance, sync... | |
SLQ Primary Current Injection Test Set | Introduction: SLQ primary current injection test setis a high current generator instrument. It is applied in current transformer test, circuit brea... | |
HYBC-901 Transformer Ratio Meter | Transformer ratio meter Itistotestvoltageratio,vector,polarity,ratioerrorofcurrenttransformerandvoltagetransformer. Transformer turns ratio met... |
Same products
ACREL AID150 ALARM AND DISPLAY DEVICE | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | The AID150 insulation monitoring device schneideris designed for visual and audible indication of... | |
ACREL ANSVG STATIC VAR GENERATOR | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel... | |
The Working Principle of Active Power Filter | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Active power filter is a new type of power electronic device used to dynamically suppress harmoni... | |
ACREL PZ72L-DE MULTIFUNCTION DC ENERGY METER | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | PZ series intelligent DC atorch electric energy meteris designed for applications such as DC pane... | |
ACREL DTSD1352-C SOLAR INVERTER SMART METER | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Acrel sungrow smart meterDTSD1352 din rail type multi-function energy meter is an intelligent ins... |