Dry Type Hipot Tester

Introduction

HIPOT tester is applied to test the insulation ability of electric power equipments and insulation materials at power frequency high voltage. The insulation test result of the tester is go or not go. Also the HIPOT tester is a universal power source in HV test. The maximum output voltage and capacity could be customized according the requirements of custom.

The tester is consists of single HV transformer and main control box. There are three kinds of HV transformer according to the insulation materials of the HV transformer. They are dry HV transformer,oil HV transformer and SF6 gas HV transformer. For the dry HV transformer the insulation material is epoxy resin. For oil HV transformer the insulation material is insulation oil. For SF6 HV transformer the insulation material is SF6 gas.The dry HV transformer has a smaller size and less weight than oil HV transformer. But the maximum output voltage is less than 100kv for dry HV transformer. The functions of the main control box are voltage output regulation, protection in emergency and voltage/current value indication.

Technique index

1)power supply:

AC 220V 50Hz/60Hz for transformers which the capacity less than 10kva

AC 380V 50Hz/60Hz for transformers which the capacity more than 10kva

2)HV transformer mode: single phase

3)maximum output voltage: 50kv/100kv/150kv/200kv/250kv optional

4)output capacity: 3kva/5kva/10kva/20kva/30kva/50kva/100kva/150kva/200kva optional

5)voltage read mode:analog or digital, direct HV voltage reading form voltmeter

6)current read mode:analog or digital, direct LV circuit current reading from amp meter

7)protection mode: LV circuit over current protection

8)voltage adjust mode: manual regulation

9)Rated frequency: 50Hz/60Hz

10)Automatic zero position lock unit to avoid wrong operation in HV output

11)work temperature: 0~50degree

12)work humidity: <80%

Model selection table

The detail power parameters for the common models HV transformer are as table 1. Please confirm the right model before order. The main parameters include input voltage, maximum output voltage and capacity.

The parameters in this table are response for HV transformer only and we will install the main control box according to the capacity and input voltage of the model you order

Table 1 Parameters for HV transformer

Type

Capacity

KVA

Low Voltage Input

High Voltage Output

No Load Current%

Impedance Voltage %

Weight max

Kg

Voltage V

Current

Voltage KV

Current mA

YD –1.5/50

200

50

30

4

10

22

YD –3/50

3

200

15

50

60

4

10

33

YD –6/50

6

200

30

50

120

4

10

53

YD –10/50

10

200

50

50

200

4

10

79

YD–10/100

10

400

25

100

100

4

10

98

Notice:

1) If the maximum voltage is less than 100kv we will offer dry HV transformer for the tester, otherwise we will offer oil HV transformer for the tester

2) The capacity and maximum voltage output could be customized according to the requirements of customer if you can not find the right one in this table

3) The weight listed in the table is HV transformer only it does not include the weight of main control box. Please confirm the total weight of the tester with our sales engineer before order



在线联系供应商

至: Wuhan Huaying Electric Power Tech & Science Co.,ltd
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

HY2305 Insulation Tester
HY2305 Insulation Tester Insulation Tester HY2305 RatedVoltage 250V 500V 1000V 2500V 5000V Measuring Range 0.0~99.9MΩ100~999MΩ1.00~10.0GΩ 0.0~99.9...
HYLB-601 instantaneous signal recorder
HYLB-601 instantaneous signal recorder Introduction: HYLB-601 is an instantaneous signal recorder applied in industry signal analysis. It takes IPC as the core for data sample and proces...
HYYJ-502A Insulating oil tester
HYYJ-502A Insulating oil tester Portable dielectric oil tester technical index: (1) AC220V±10% power supply input (2) Output voltage:AC 0V~100KV (3) Rate of voltag...
HYKC-2000 On Load Tap Changer Ohmmeter Analyzer
HYKC-2000 On Load Tap Changer Ohmmeter Analyzer 1.Introduction On load tap changer analyzer HYKC-2000 is mainly applied to test transient time, transition waveform, transition resistance, sync...
HYVA-402V ct pt analyzer
HYVA-402V ct pt analyzer CT PT AnalyzerFunctions: 1 Turns Ratio, ratio error and phase error test2 Polarity test for CT3 Excitation curve and knee voltage measurement i...
供应产品

Same products

S11-M Power Transformer
S11-M Power Transformer 卖方: Bokong Electric Co., Ltd S11-M Product Description S11-M a new generation of low noise and low loss transformer devel...
Compact Transformer
Compact Transformer 卖方: Shaanxi Hanzhong Transformer Co., ltd As a leading compact transformer substationmanufacturer and box type substation supplier, SEC com...
Combined Pad Mounted Substation
Combined Pad Mounted Substation 卖方: Shaanxi Hanzhong Transformer Co., ltd Combined Pad Mounted Substation The ZBG series America Housing Type Transformer are researched a...
Amorphous Alloy Dry Type Transformer
Amorphous Alloy Dry Type Transformer 卖方: Shaanxi Hanzhong Transformer Co., ltd SCBH15eres amorphous alloy dry type transformerpertorms well not only for its excellent propertie...
35KV Power Transformer
35KV Power Transformer 卖方: Shaanxi Hanzhong Transformer Co., ltd This 35 KV transformerhas the characteristics of high efficiency and low loss, can save a lot of ...