High Precision Easy For Installation Linear Output Mini Current Transformer

1.Regular spec: 10 (100)A/4mA
Other spec can be request
Dielectric strength: not less than 4kV/1mA/1min
Insulation resistance: >500M Ohm (500V DC)
Operating temperatures: -40 to +85 Degrees Celsius
Relative humidity range: less than or equal to 95% (25 Degrees Celsius)
Altitude: less than or equal to 10000m
High precision
Suitable for kWh meter class 0.2, class 0.5, class 1.0.
Very reliable and stable performance at different temperature conditions
The primary lead wire can be linked to the connector directly
Fully enclosed case, with high function of current Isolation and nice outline.
2.Regular spec: 1 (20)A/0.4mA other spec also can be requested
Housing material: anti-burning ABS.
Encapsulation: epoxy resin.
Ambient temperature: -40 Degrees Celsius - +85 Degrees Celsius.
Insulation resistance: more than or equal to 500M Ohm (DC 500V).
Dielectric strength: 4000V/1mA/1min.
High accuracy, excellent linearity performance.
The primary is LED out by copper conductor which can be installed to the meter connector directly.
Linear output with high accuracy current.
DC immunity function.
3.Regular spec: 5(100)A/2mA
Other spec can be requested
DC immunity
Dielectric strength: not less than 4kV/1mA/1min
Insulation resistance: >500M Ohm (500V DC)
Operating temperature: -40 to +85 Degrees Celsius
Relative humidity: less than or equal to 95% (25 Degrees Celsius) Altitude: less than or equal to 10000m
High precision
Suitable for kWh meter class 0.2, class 0.5, class 1.0.
Typical AC current measurement error is within 0.02% at Ib test point
Typical phase shift is at 1-10', additional compensation is not needed
Fully enclosed case, with high function of current isolation and nice outline;
4.Regular spec: 5(60) A/2.5mA 0.1CLASS 20 Ohm
Other spec can be requested
Dielectric strength: not less than 4kV/1mA/1min
Insulation resistance: >500M Ohm (500V DC)
Operating temperature: -40 to +85 Degrees Celsius
Relative humidity: less than or equal to 95% (25 Degrees Celsius), altitude: less than or equal to 10000m
High precision
Suitable for kWh meter class 0.2, class 0.5, class 1.0.
Typical AC current measurement error is within 0.02% at Ib test point
Typical phase shift is at 1-10', additional compensation is not needed
Fully enclosed case, with high function of current isolation and nice outline


在线联系供应商

至: Deqing GIG Electronic Co., Ltd
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

PCB Use Modular Meter Toroidal High Frequency Current Transformer
PCB Use Modular Meter Toroidal High Frequency Current Transformer 1.Electric strength: not less than 4kV/1mA/1min Operating temperature: -40 to +85 Degrees Celsius Relative humidity: less than or equal to 95% (25 ...
Small Size High Precision Strong Voltage Isolation Ability Mini Current Transformer
Small Size High Precision Strong Voltage Isolation Ability Mini Current Transformer Regular spec: Housing material: anti-burning ABS Ambient temperature: -40 to +85 Degrees Celsius Insulation resistance: more than or equal to 500M ...
Less power consumption Lower temperature­rise Equivalent of VAC Current Transformer
Less power consumption Lower temperature­rise Equivalent of VAC Current Transformer Spec can be requested: Primary current: 5A Imax: 120A Accuracy class: 0.1% Turns ratio: 1:2500 Load resistance: 10 Ohm Frequency: 50Hz-60Hz Dielect...
Adopted High Permeability Core Flexible wires Instrument Use Current Transformer
Adopted High Permeability Core Flexible wires Instrument Use Current Transformer Primary current: 1A Imax: 10A Accuracy class: 0.1% Load resistance: 10 Ohm Frequency: 50-60Hz Dielectric withstanding volt (Hi-pot): 4KVrms Ambient...
Custom Design Busbar Type Cost Saving Current Transformer
Custom Design Busbar Type Cost Saving Current Transformer Regular spec: 5 (20) A/5mA 0.2% 10 Ohm other spec can be requested DC immunity.Anti-magnetic current transformer Dielectric strength: not less than...
供应产品

Same products

China factory Transformer bushing BRDW-126/630-3 for power station
China factory Transformer bushing BRDW-126/630-3 for power station 卖方: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China factory Transformer bushing BRDW-126/630-3 for power station YOYIK is a research and devel...
TOROIDAL TRANSFORMER
TOROIDAL TRANSFORMER 卖方: Yu Yang Magnetic Co., LTD Seamless toroidal core (ferrite/powdered iron) minimizes core loss (<1.1W/kg) and achieves >...
ACREL AID150 ALARM AND DISPLAY DEVICE
ACREL AID150 ALARM AND DISPLAY DEVICE 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. The AID150 insulation monitoring device schneideris designed for visual and audible indication of...
ACREL ANSVG STATIC VAR GENERATOR
ACREL ANSVG STATIC VAR GENERATOR 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel...
The Working Principle of Active Power Filter
The Working Principle of Active Power Filter 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. Active power filter is a new type of power electronic device used to dynamically suppress harmoni...