Pakistan Energy Meter Terminal Box Assembly Use Plastic Case Current Transformer

Measurement CT with Power Up CT
Measurement CT
Primary current: 5A
Imax: 40A
Accuracy class: 0.1%
Load resistance: 10 Ohm
Frequency: 50Hz-60Hz
Power Up CT
Rated: 1A
Maxi: 40A
Dielectric withstanding volt (Hi-pot): 4KVrms
Ambient temp: -40-+70 Degrees Celsius
Storage temp: -40-+80 Degrees Celsius
Encapsulant: epoxy
Dielectric strength: not less than 4kV/1mA/1min.
Insulation resistance: >500M Ohm (500VDC).
Operating temperature: -40 Degrees Celsius~ +85 Degrees Celsius.
Relative humidity: less than or equal to 95% (25 Degrees Celsius) Altitude: less than or equal to 10000m.
AC measurement capacity is 20% higher than rated current.
High precision. Suitable for kWh meter Class 0.2, Class 0.5, Class 1.0.
Typical AC current measurement error is within 0.02% at Ib test point.
Typical phase shift is at 1-10’, additional compensation is not needed.
Very reliable and stable performance at different temperature conditions.


在线联系供应商

至: Deqing GIG Electronic Co., Ltd
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

High-precision ABS Anti-combustion Plastic Casing Current Transformer
High-precision ABS Anti-combustion Plastic Casing Current Transformer Regular spec: Primary current: 60A Imax: 200A Accuracy class (%): 0.1 Load resistance: 10 Ohm Frequency: 50HZ-60HZ Dielectric Withstanding Volt(Hi-...
High Accuracy lightweight Small Volume Mini Current Transformer
High Accuracy lightweight Small Volume Mini Current Transformer Primary current: 5A Imax: 100A Accuracy class: 0.1 Turns ratio: 1:2500 Load resistance: 20 Ohm Frequency: 50Hz-60Hz Dielectric withstanding volt (H...
PCB-Mounted Type 4 pins Smart Meter Use Mini Current Transformer
PCB-Mounted Type 4 pins Smart Meter Use Mini Current Transformer 1.Electric strength: not less than 4kV/1mA/1min Operating temperature: -40 to +85 Degrees Celsius Relative humidity: less than or equal to 95% (25 ...
Round DC immunity Metal Shield 1:2500 Current Transformer
Round DC immunity Metal Shield 1:2500 Current Transformer Dielectric strength: not less than 4kV/1mA/1min Insulation resistance: >500M Ohm (500V DC) Operating temperature: -40 to +85 Degrees Celsius Rel...
Three Phase Imax 40A Kwh meter Use Current Sensor
Three Phase Imax 40A Kwh meter Use Current Sensor Regular spec: Primary current: 10A Imax: 40A Accuracy class (%): 0.1 Load resistance: 6.25 Ohm Frequency: 50HZ-60HZ Dielectric Withstanding Volt(Hi...
供应产品

Same products

China factory Transformer bushing BRDW-126/630-3 for power station
China factory Transformer bushing BRDW-126/630-3 for power station 卖方: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China factory Transformer bushing BRDW-126/630-3 for power station YOYIK is a research and devel...
TOROIDAL TRANSFORMER
TOROIDAL TRANSFORMER 卖方: Yu Yang Magnetic Co., LTD Seamless toroidal core (ferrite/powdered iron) minimizes core loss (<1.1W/kg) and achieves >...
ACREL AID150 ALARM AND DISPLAY DEVICE
ACREL AID150 ALARM AND DISPLAY DEVICE 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. The AID150 insulation monitoring device schneideris designed for visual and audible indication of...
ACREL ANSVG STATIC VAR GENERATOR
ACREL ANSVG STATIC VAR GENERATOR 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel...
The Working Principle of Active Power Filter
The Working Principle of Active Power Filter 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. Active power filter is a new type of power electronic device used to dynamically suppress harmoni...