Do You Know What Is The Short Circuit Impedance of The Transformer?
process of using, it is necessary to enhance the continuous improvement of the use and efficiency of the transformer such asDry Type Transformer. Since the voltage of the transformer such asCast Resin Transformeris affected by many factors, the voltage is controlled and used. The pressure of adjustment is not the same. The impedance of the short circuit of the transformer is also a major cause of the transformer's operation and one of the most effective means of controlling the voltage. So what is the meaning of the short-circuit impedance of the transformer in actual operation and operation? Here we will give you a detailed introduction:
Concept A
Generally, the short-circuit impedance of a transformer refers to the equivalent series impedance Zk=Rk+jXk between the terminals of a pair of windings at a rated frequency and a reference temperature. Since its value is determined by the load test in addition to the calculation, it is customarily referred to as the short-circuit voltage or the impedance voltage.
Concept B
The short-circuit impedance is an important item in the performance index of the transformer, and the deviation between the measured value and the specified value at the time of shipment is very strict.
Influence of transformer short-circuit impedance on transformer operation
Transformer short-circuit impedance, also called impedance voltage, is defined in the transformer industry: when the secondary winding of the transformer is short-circuited (steady-state), the voltage applied by the primary winding to the rated current is called the impedance voltage Uz. Usually Uz is expressed as a percentage of the rated voltage, ie uz=(Uz/U1n)*100%
When the transformer is fully loaded, the level of the short-circuit impedance has a certain influence on the output voltage of the secondary side. The short-circuit impedance is small, the voltage drop is small, the short-circuit impedance is large, and the voltage drop is large. When the transformer load is short-circuited, the short-circuit impedance is small, the short-circuit current is large, and the electric power that the transformer is subjected to is large. The short-circuit impedance is large, the short-circuit current is small, and the electric force that the transformer is subjected to is small.
The above is the impedance effect of the short circuit of the transformer and the basic analysis of the concept for your reference. Everyone can continuously promote the stability and stability of the transformer. In this case, many effects of the transformer will be exerted, and it is safer.
The company mainly produces: , dry-type transformers, box-type substation, and a variety of special-type transformers. The hoisting, tooling and testing equipments are complete. Our company has passed the ISO9001-2015 international standard quality management system certification. All performance indicators of the products have reached the relevant national standards and international standards.
If you want to know more about the product, please.
MoreProductsPlease View.
在线联系供应商
Other supplier products
Dry type Power Transformers | Product Description SG (B) 10 series of non-encapsulated H-class dry-type power transformersadopt the special process technology of German (MORA) d... | |
What Are the Classifications of Substations? | Substations such as thePrefabricated Substationhave the following classifications: (1) A type of substation. It refers to the exchange of UHV stat... | |
[Transformers for sale]How can oil-immersed transformers reduce copper loss? | How can the copper loss of transformer be reduced in long - term operation? Shared byoil immersed transformer supplier. That's all for the sharing... | |
Amorphous alloy power transformer China | is a new type of energy saving transformer made of a new magnetic conducting material (amorphous alloy). It is more than 70% lower than the no-loa... | |
KYN28A-12 (GZS1-12) Model Indoor AC Metal Clad Intermediate Switchgear,KYN28A-12 (GZS1-12) Indoor AC Metal Clad Intermediate Switchgear,Circuit Breaker Switchgear,High and Low Voltage Switchgears,Indo | KYN28A-12 (GZS1-12) Model Indoor AC Metal Clad Intermediate Switchgear,KYN28A-12 (GZS1-12) Indoor AC Metal Clad Intermediate Switchgear,Circuit Bre... |
Same products
S11-M Power Transformer | 卖方: Bokong Electric Co., Ltd | S11-M Product Description S11-M a new generation of low noise and low loss transformer devel... | |
Compact Transformer | 卖方: Shaanxi Hanzhong Transformer Co., ltd | As a leading compact transformer substationmanufacturer and box type substation supplier, SEC com... | |
Combined Pad Mounted Substation | 卖方: Shaanxi Hanzhong Transformer Co., ltd | Combined Pad Mounted Substation The ZBG series America Housing Type Transformer are researched a... | |
Amorphous Alloy Dry Type Transformer | 卖方: Shaanxi Hanzhong Transformer Co., ltd | SCBH15eres amorphous alloy dry type transformerpertorms well not only for its excellent propertie... | |
35KV Power Transformer | 卖方: Shaanxi Hanzhong Transformer Co., ltd | This 35 KV transformerhas the characteristics of high efficiency and low loss, can save a lot of ... |