d6-35 Oil-Immersed Oil-Filled Type Potential Voltage Transformer PT 27.5kv, 35kv, 66kv, 72.5kv, 110kv, 126kv, 220kv, 245kv
35-220kV Oil-filled/Oil-immersed type potential/voltage transformer
JD6-35 Oil-immersed type voltage transformer
Model description
JD6-35(GY)(TA,TH)(W1,W2,W3)
J: Voltage transformer
D:Single-phase
6: Design no.
35: Rated voltage(kV)
GY: Altiplano type
TA: Dry tropical zone
TH: Wet tropical zone
W1,W2,W3: Pollution level
JD6-35W3
JD6-27.5W3
JDX6-35 Oil-filled type potential transformer
Model description
JDX6-35(GY)(TA,TH)(W1,W2,W3)
J: Voltage transformer
D:Single-phase
X: Residual voltage winding
6: Design no.
35: Rated voltage(kV)
GY: Altiplano type
TA: Dry tropical zone
TH: Wet tropical zone
W1,W2,W3: Pollution level
JDX6-35W3
JDX6-35W2
JDCF-66 Oil-immersed type voltage transformer
Type description
JDCF-66(GY)(TA,TH)(W1,W2,W3)
J: Voltage transformer
D:Single-phase
C: Cascade structure
F: Divided metering and protection windings
66: Rated voltage(kV)
GY: Altiplano type
TA: Dry tropical zone
TH: Wet tropical zone
W1,W2,W3: Pollution level
JDCF-66 W3
JDCF-66(72.5)
JDX6-66 Oil-filled type potential transformer
JDX6-66W3
JDCF-110 Oil-immersed type voltage transformer
Model description
JDCF-110(GY)(TA,TH)(W1,W2,W3)
J: Voltage transformer
D:Single-phase
C: Cascade structure
F: Divided metering and protection windings
110: Rated voltage(kV)
GY: Altiplano type
TA: Dry tropical zone
TH: Wet tropical zone
W1,W2,W3: Pollution level
JDCF-110W3
JDCF-110(126)
JDCF-220 Oil-filled type potential transformer
JDCF-220W3
JDCF-220(245)W2
Rated voltage ratio (V) |
Accuracy class and accuracy class combination Rated secondary output(VA) |
Limited output(VA) |
Rated insulation level(Kv) |
Rated secondary output(VA) |
Surface creepage distance(mm) |
Once fuse(A) |
Auxiliary winding |
Rated voltage factor |
Porcelain bushing creepage distance(mm) |
Frequency(Hz) |
Altitude(m) |
Discharge capacity(MVar) |
Rated primary current I1n(A) |
Double transformation ratio |
Single transformation ratio |
Thermal current/1s(Ka effect value) Ith/1s(Ka r.m.s) |
Dynamic stable current Idyn(Ka peak) |
Ampere-turn |
Residual voltage winding accuracy class and Rated burden(VA) |
|
|
|
|
在线联系供应商
Other supplier products
供应产品Same products
ACREL AID150 ALARM AND DISPLAY DEVICE | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | The AID150 insulation monitoring device schneideris designed for visual and audible indication of... | |
ACREL ANSVG STATIC VAR GENERATOR | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | ANSVG series of reactive power and harmonic hybrid compensation devices are connected in parallel... | |
The Working Principle of Active Power Filter | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Active power filter is a new type of power electronic device used to dynamically suppress harmoni... | |
ACREL PZ72L-DE MULTIFUNCTION DC ENERGY METER | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | PZ series intelligent DC atorch electric energy meteris designed for applications such as DC pane... | |
ACREL DTSD1352-C SOLAR INVERTER SMART METER | 卖方: Jiangsu Acrel Electrical Manufacturing Co., LTD. | Acrel sungrow smart meterDTSD1352 din rail type multi-function energy meter is an intelligent ins... |