Standard Motion Sensor Module

DC Input Motion Sensor Module

Standard Motion Sensor Module

5V/12V DC Input Microwave Motion Sensor - Standard Version

HNS101D

Input voltage 12V DC (5V & 24V DC version available on request).

Input current:≥25mA.

Features

Input voltage 12V DC (5V & 24V DC version available on request).

Input current:≥25mA.

5V DC PWM output or 0~10V DC signal.

Super compact, flexible to be integrated into any suitable fixtures.

Dual-PD technology, real Daylight monitoring function for built-in application.

8 pin DIP switch setting, multiple options to meet different customer demands.

Detection range up to 12m in diameter.

Mounting height: 3~6m.

Operation temperature; -20℃ ~ + 70℃.

RoHS compliant.

Settings

Detection range

Detection range can be reduced by selecting the combination on the DIP switches to fit precisely each application.

Hold-time

Hold-time means the time period to keep the lamp on 100% after motion detected.

*when hold-time set as 3s, sensor enters into test mode, this test mode is mainly for users to choose the desired detection range. In this mode, the daylight sensor is disabled, when there is no motion, fixture keeps off, when there is motion detected, fixture keeps a cycle of 3s on and 2s off.

Daylight sensor

Daylight sensor means the daylight threshold to enable or disable the sensor function.

"Disable": The sensor works always, even during daylight.

w50lux": The sensor works only in twilight.

w10lux, 2luxw: The sensor works only in the dark.

Stand-by period

This is the time period that the lamp remains at a low light level before it is completely switched off in the long absence of people.

“+∞”: means bi-level dimming control, the fixture never switch off.

Stand-by dimming level

This is the dimmed low light level you would like to have after the hold-time in the absence of people.

Daylight monitoring function

Utilizing the Dual-PD technology, this sensor can tell the difference of natural light and artificial light(lamp) from behind the diffuser, switch on automatically(even without movements) when the ambient light is below target value, and then switch off automatically whenever the artificial light is not required(ambient light is bright enough).

This is the REAL & INTELLIGENT daylight monitoring sensor for built-in installation.

Note: Lux-Off sampling time—30s; Lux-On sampling time—10s.

Lux-On function takes effect only when standby dimming period set at+∞

More information please view .


在线联系供应商

至: Hynall Intelligent Control Co. Ltd
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Remote Control DC Input Motion Sensor
Remote Control DC Input Motion Sensor Remote Control DC Input Motion Sensor Motion Sensor Module DC Input 5V/12V DC Input Microwave Motion Sensor – Remote Controllable Version ...
5V/12V DC Input Microwave Motion Sensor – Remote Controllable Version
5V/12V DC Input Microwave Motion Sensor – Remote Controllable Version 5V/12V DC Input Microwave Motion Sensor – Remote Controllable Version Remote Control DC Input Motion Sensor Motion Sensor Module DC Input ...
5V/12V DC Input Microwave Motion Sensor – Highbay Version
5V/12V DC Input Microwave Motion Sensor – Highbay Version 5V/12V DC Input Microwave Motion Sensor – Highbay Version DC Input Motion Sensor Module Highbay DC Input Motion Sensor HNS111HB Input vol...
AC Input Microwave Motion Sensor - Highbay Version
AC Input Microwave Motion Sensor - Highbay Version AC Input Microwave Motion Sensor - Highbay Version AC Input Microwave Motion Sensors Microwave Motion Sensors AC Input HNS203HB Operating volta...
Microwave Sensor
Microwave Sensor Microwave Motion Sensor Antenna Module Microwave Sensor Microwave Motion Sensor HNM01 Low cost. Patch antenna, antenna gain: 2 dBi. Beam aper...
供应产品

Same products

China manufacturer Electrode of contact water level gauge DJY2212-115 for power generation
China manufacturer Electrode of contact water level gauge DJY2212-115 for power generation 卖方: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China manufacturer Electrode of contact water level gauge DJY2212-115 for power generation The u...
China supplier temperature sensor WZPA6*50B-3*1500 power plant spare parts
China supplier temperature sensor WZPA6*50B-3*1500 power plant spare parts 卖方: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China supplier temperature sensor WZPA6*50B-3*1500 power plant spare parts Deyang YOYIK is a str...
China supplier flowmeter D2-FA50-65E/LL power plant spare parts
China supplier flowmeter D2-FA50-65E/LL power plant spare parts 卖方: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China supplier flowmeter D2-FA50-65E/LL power plant spare parts YOYIK produced by the developmen...
China made Card module DQ600-0-5W/1 for power plant
China made Card module DQ600-0-5W/1 for power plant 卖方: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China made Card module DQ600-0-5W/1 for power plant Deyang Dongfang Yoyik is a strong manufactur...
China made Gap probe GJCT-15-E for power plant
China made Gap probe GJCT-15-E for power plant 卖方: DONGFANG YOYIK (DEYANG) ENGNIEERING CO; LTD "China made Gap probe GJCT-15-E for power plant Deyang YOYIK is a strong technical force, first-c...