NTMCWOEU Flexible Medium-Voltage Single Core Cable VDE 0250 Part 813

NTMCWOEU Flexible Medium-Voltage Single Core Cable VDE 0250 Part 813ApplicationsThese cables are used for connection in switch-gear and for connection of mobile transformer substations to the overhead line.StandardsVDE 0250 Part 813ConstructionConductorsFlexible strandedcopper conductor,Website:, class 5 according to DIN VDE 0295.Inner Conductor LayerSpecial conductive rubber.InsulationEPR type 3GI3.Outer Conductor LayerSpecial conductive rubber.ScreenSpiral of tinned copper wires.Outer SheathPCP type 5GM3.Dimensions and Weight6/10kVNumber of Cores×Nominal Cross SectionInsulation ThicknessThickness of Outer SheathNominal Overall DiameterNominal WeightNo.×mm²mmmmmmkg/km1×16/163.42.222.07601×25/163.42.223.59101×35/163.42.224.510401×50/163.42.227.012601×70/163.42.528.515301×95/163.42.530.517701×120/163.42.533.521801×150/253.43.035.025501×185/253.43.037.029001×240/253.43.541.035901×300/253.43.543.042801×400/353.44.046.051201×500/353.44.049.059501×630/353.44.053.5786012/20kVNumber of Cores×Nominal Cross SectionInsulation ThicknessThickness of Outer SheathNominal Overall DiameterNominal WeightNo.×mm²mmmmmmkg/km1×25/165.52.528.011801×35/165.52.529.513201×50/165.52.531.515601×70/165.53.034.019201×95/165.53.036.021901×120/165.53.038.024601×150/255.53.540.029901×185/255.53.542.033501×240/255.53.545.039901×300/255.53.548.047601×400/355.54.052.061001×500/355.54.056.070101×630/355.54.060.0818014/25kVNumber of Cores×Nominal Cross SectionInsulation ThicknessThickness of Outer SheathNominal Overall DiameterNominal WeightNo.×mm²mmmmmmkg/km1×25/166.83.030.513001×300/256.84.049.0490018/30kVNumber of Cores×Nominal Cross SectionInsulation ThicknessThickness of Outer SheathNominal Overall DiameterNominal WeightNo.×mm²mmmmmmkg/km1×50/168.03.035.0187020/35 kVNumber of Cores×Nominal Cross SectionInsulation ThicknessThickness of Outer SheathNominal Overall DiameterNominal WeightNo.×mm²mmmmmmkg/km1×95/169.53.544.029001×150/259.53.546.336001×240/259.54.051.75000
Other supplier products
|
|
|
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, PVC Jacket, 8kV ICEA S-75-381ApplicationsThese cables are designed for connections bet... |
|
|
|
Flame Retardant RS485 Databus Cablespplication:The cables are designed for RS485 data connections where continued functionality is required during ... |
|
|
|
German Standard Industrial Cables H05VV5-F(NYSLYÖ-JZ)Application and DescriptionThese cables are suitable for dry,Website:, damp and wet locations ... |
|
|
|
Flame Retardant RS485 Databus Cables Application:Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol,Website:, suitable ... |
|
|
|
Multicore Unscreened Armoured Cables-Belden Equivalent 26514ApplicationsThese multipair overall screened armoured cables provide excellent protecti... |