NAYCY

German Standard Industrial Cables NAYCYApplication and DescriptionNAYCY is used in power plants,Website:, industrial and switching installations, for street lighting, domestic power supply connections, in secondary distribution networks and other. These cables are preferentially used for underground application as well as for interior installation in room and cable ducts and for outdoor and applications, for indoor installations, in tde open air, underground and in water where greater mechanical protection against accidental contact is required if damaged.Standard and ApprovalVDE 0276 part 603, IEC 60502Cable Construction1- Aluminium Conductor- VDE 0295 cl. 1 or cl. 2 (round and sector shaped), BS 6360/IEC 60228 cl. 1 or cl. 22- PVC insulation type DIV4 acc. VDE0276- Color coded to DIN VDE 02933- Tapes and PVC compound inner sheatd4- Concentric conductor: Copper wires and copper tapes5- PVC outer sheatd type DMV5 acc. VDE 0276Technical Characteristics- Working voltage: 600/1000 volts- Test voltage: 4000 volts- Minimum bending radius: 12 x Ø- Flexing temperature: -5º C to +50º C- Fixed installation temperature: - 30º C to +70º C- Short circuit temperature: +160º C- Flame-retardant to DIN VDE 0472 part 804 class B/IEC 60332-1- Insulation resistance: 20 MΩ x kmCable ParameterAWGNO. OF CORE ANDNOMINAL CROSSSECTIONAL# X MM²STRANDED CONDUCTOR TYPECONCENTRICCONDUCTOR SIZE MM²NOMINALOVERALL DIAMETER MMALUMINIUM WEIGHT KG/KMCOPPER WEIGHT KG/KMNOMINALCABLE WEIGHT KG/KM23 x 35.0re3527. x 50.0re5031./03 x 70.0se7033./03 x 95.0se9536./03 x 120.0se12040./03 x 70.0sm3533./03 x 70.0sm7034./03 x 95.0sm5037./03 x 95.0sm9538./03 x 120.0sm7040./03 x 120.0sm12040.mcm3 x 150.0sm7044.mcm3 x 150.0sm15045.mcm3 x 185.0sm9548.
Other supplier products
|
|
|
Type G-GC Three-Conductor Flat Portable Power Cable 2kV ICEA S-75-381ApplicationsThese flat parallel cables are designed for use on ACmining equipm... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8315ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
German Standard Industrial Cables N2XRYApplication and DescriptionN2XRY is used for indoor,Website:, ourdoor and underground installation in ducts ... |
|
|
|
P7 or P7/P14 BFOU 6/10kV Fire resistant NEK606 MV cableApplications :These cables are fire resistant,Website:, flame retardant, low smoke, halogen ... |
|
|
|
Industrial Cables H05V-KApplication and DescriptionThese insulated wires are determined for installation to tde inside of apparatus as well as for ... |
供应产品
Same products