150/250V HF-EPR Insulated, SW2/SW4 Sheathed, Collectively Screened Unarmoured Flame Retardant Instrumentation Control Cables

150/250V HF-EPR Insulated,Website:, SW2/SW4 Sheathed, Collectively Screened Unarmoured Flame Retardant Instrumentation & Control CablesApplication:These elastomeric insulated cables are designed for fixed wiring in ships and on mobile offshore units, suitable for use in instrumentation, lighting and control circuits.Standards:BS 6883IEC 60332-3A Flame retardantIEC 60754-1; IEC 60754-2 CorrosivityIEC 61034-2 Smoke densityCold bend and impact (-40°C) (on request)CSA C22.2 No. 38-95 (on request)Construction:Conductor: Tinned copper wire stranded circular cl. 2 BS 6360/IEC 60228.Insulation: HF-EPR GP4 according to BS 7655 1.2.Lay-up: Pairs, triples, quads.Individual Screen: Aluminium/polyester tape + drain wire tinned copper.Sheath: Halogen free thermosetting compound SW4 according to BS 7655 2.6 or reduced halogen thermosetting compound SW2 according to BS 7655 2.6.Mechanical and Thermal Properties:Minimum Internal Bending Radius: 8×ODTemperature Range: -40℃ ~ +90℃Dimensions and WeightInsulation Colour SchemeConstruction
No. of cores×Cross section(mm²)Nominal Insulation Thickness
mmNominal Sheath Thickness
mmMinimum Overall Diameter
mmMaximum Overall Diameter
mmApprox. Weight
kg/kmMultipair3×2×0.750.81.212.614.51757×2×0.750.81.416.618.733012×2×0.750.81.621.724.253020×2×0.750.81.827.330.183027×2×0.750.81.931.134.2107037×2×0.750.82.134.437.714303×2×10.81.213.315.31857×2×10.81.417.619.836012×2×10.81.623.125.759020×2×10.81.829.131.992027×2×10.82.033.336.6122037×2×10.82.236.940.31630Multitriple3×3×0.750.81.314.216.22307×3×0.750.81.419.421.944012×3×0.750.81.724.226.87303×3×10.81.315.117.12607×3×10.81.520.923.451012×3×10.81.725.828.5840
Other supplier products
|
|
|
Type 240 1.1 to 11KV to AS/NZS 1802ApplicationsThese cables are mainly used as feeder cables for power supply to machinery or longwall supply.Cable... |
|
|
|
Armoured Cat 6 S/FTP 23AWG IEC60092ApplicationThese Cat6 S/FTP cables are manufactured in accordance with IEC 61156-5 requirements,Website:, can su... |
|
|
|
Tight Buffer Optical Fiber Cables ApplicationThese optical fiber cables are designed to data transmission in ship and specially in cruise ship wher... |
|
|
|
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, PVC Jacket, 5kV ICEA S-75-381ApplicationsThese cables are designed for connections bet... |
|
|
|
German Standard Industrial Cables N2XRYApplication and DescriptionN2XRY is used for indoor,Website:, ourdoor and underground installation in ducts ... |