(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable Without Fibre Optics

N)TSCGEWOEU Medium-Voltage Fixed Installation Cable Without Fibre OpticsApplicationsThese cables are used for laying alongside the conveyor belts (also for shiftable units)and on material handling equipment (even with continuous movementsuch as in cable booms or as connection between upperand lower car) and for connection of submersible pump units.StandardsBased on VDE 0250 Part 813ConstructionConductorsFlexible strandedcopper conductor,Website:, class 5 according to DIN VDE 0295.Inner Conductor LayerSemiconductive layer.InsulationEPR.Outer Conductor LayerSemiconductive layer.Earth ConductorSplit into three in the outer interstices.InnerSheathEPR.Outer SheathCM.Dimensions and Weight3.6/6 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/336.739.723203×25+3×50/340.643.628603×35+3×25/340.543.528603×35+3×50/342.345.332203×50+3×25/343.846.835003×50+3×50/343.846.836503×70+3×35/347.050.043603×70+3×50/349.753.750103×95+3×50/352.256.255503×120+3×70/355.959.966903×150+3×70/361.065.080303×185+3×95/364.068.093203×240+3×120/372.176.1119603×300+3×150/377.381.3142606/10 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/339.042.025203×25+3×50/341.444.429303×35+3×25/341.844.829803×35+3×50/343.646.633503×50+3×25/345.148.136403×50+3×50/345.148.137803×70+3×35/348.351.345003×70+3×50/348.351.347303×95+3×50/353.557.557103×120+3×70/357.261.268603×150+3×70/362.366.382103×185+3×95/365.369.395103×240+3×120/373.477.4121703×300+3×150/378.682.6145008.7/15 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/342.545.528503×25+3×50/344.247.232103×35+3×25/345.348.333403×35+3×50/345.348.334803×50+3×25/349.453.441803×50+3×50/349.453.443203×70+3×35/352.756.750903×70+3×50/352.756.753103×95+3×50/357.061.061603×120+3×70/362.166.175503×150+3×70/365.769.787103×185+3×95/368.772.7100203×240+3×120/376.880.8127503×300+3×150/382.086.01511012/20 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/345.548.531503×25+3×50/345.548.533003×35+3×25/348.351.336603×35+3×50/348.351.338003×50+3×25/352.556.545403×50+3×50/352.556.546803×70+3×35/355.759.754603×70+3×50/355.759.756903×95+3×50/361.465.467703×120+3×70/365.169.179803×150+3×70/368.772.791703×185+3×95/373.277.2107803×240+3×120/379.883.8132803×300+3×150/386.391.31607014/25 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/350.354.337503×25+3×50/350.354.339003×35+3×25/353.157.142903×35+3×50/353.157.144303×50+3×25/356.360.350203×50+3×50/356.360.351603×70+3×35/361.065.061903×70+3×50/361.065.064103×95+3×50/365.369.373403×120+3×70/369.073.085803×150+3×70/374.078.0100503×185+3×95/377.081.0114303×240+3×120/385.090.0144003×300+3×150/390.295.21686018/30kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/353.757.741603×25+3×50/353.757.743003×35+3×25/356.660.647303×35+3×50/356.660.648703×50+3×25/361.265.257003×50+3×50/361.265.258403×70+3×35/364.468.466803×70+3×50/364.468.469003×95+3×50/368.772.778603×120+3×70/373.877.893903×150+3×70/377.581.5106603×185+3×95/380.584.5120603×240+3×120/388.593.5150903×300+3×150/394.799.717820

在线联系供应商

至: UNIVERSAL CABLES LIMITED
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

S3 or S3/S7 BFOU(i) 250V Armour & Individual Shielding fire resistant NEK606 Instrument cableApplications :These cables are fire resistant,Website:...
300/500V Mica+XLPE Insulated Individual And Overall Screened fire resistant Instrumentation CablesRE-2X(St)H PiMF...CI. FE 180 PH30 ( CU/MGT+XLPE/I...
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8340ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl...
German Standard Industrial Cables N2XRYApplication and DescriptionN2XRY is used for indoor,Website:, ourdoor and underground installation in ducts ...
3.6/6kV,Website:, 6/10kV, 8.7/15kV XLPE Insulated, LSOH (SHF1)Sheathed, Armoured Flame Retardant MV Power Cables (SHF1 Inner Sheath)ApplicationThes...
供应产品

Same products

PMMA VR Lens For Google Cardboard
PMMA VR Lens For Google Cardboard 卖方: 金华市凯跃光电科技有限公司 PMMA VR Lens For Google Cardboard,Double Convex Lens
PMMA Double Convex Lens
PMMA Double Convex Lens 卖方: 金华市凯跃光电科技有限公司 PMMA Double Convex Lens,Double Convex Lens
6X21 PBinoculars
6X21 PBinoculars 卖方: 金华市凯跃光电科技有限公司 6X21 PBinoculars,Porro Prism Binoculars
Night Vision Binoculars
Night Vision Binoculars 卖方: 金华市凯跃光电科技有限公司 Night Vision Binoculars,Porro Prism Binoculars
10X25 High Power Binoculars
10X25 High Power Binoculars 卖方: 金华市凯跃光电科技有限公司 10X25 High Power Binoculars,Binoculars & Scopes