(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable Without Fibre Optics

N)TSCGEWOEU Medium-Voltage Fixed Installation Cable Without Fibre OpticsApplicationsThese cables are used for laying alongside the conveyor belts (also for shiftable units)and on material handling equipment (even with continuous movementsuch as in cable booms or as connection between upperand lower car) and for connection of submersible pump units.StandardsBased on VDE 0250 Part 813ConstructionConductorsFlexible strandedcopper conductor,Website:, class 5 according to DIN VDE 0295.Inner Conductor LayerSemiconductive layer.InsulationEPR.Outer Conductor LayerSemiconductive layer.Earth ConductorSplit into three in the outer interstices.InnerSheathEPR.Outer SheathCM.Dimensions and Weight3.6/6 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/336.739.723203×25+3×50/340.643.628603×35+3×25/340.543.528603×35+3×50/342.345.332203×50+3×25/343.846.835003×50+3×50/343.846.836503×70+3×35/347.050.043603×70+3×50/349.753.750103×95+3×50/352.256.255503×120+3×70/355.959.966903×150+3×70/361.065.080303×185+3×95/364.068.093203×240+3×120/372.176.1119603×300+3×150/377.381.3142606/10 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/339.042.025203×25+3×50/341.444.429303×35+3×25/341.844.829803×35+3×50/343.646.633503×50+3×25/345.148.136403×50+3×50/345.148.137803×70+3×35/348.351.345003×70+3×50/348.351.347303×95+3×50/353.557.557103×120+3×70/357.261.268603×150+3×70/362.366.382103×185+3×95/365.369.395103×240+3×120/373.477.4121703×300+3×150/378.682.6145008.7/15 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/342.545.528503×25+3×50/344.247.232103×35+3×25/345.348.333403×35+3×50/345.348.334803×50+3×25/349.453.441803×50+3×50/349.453.443203×70+3×35/352.756.750903×70+3×50/352.756.753103×95+3×50/357.061.061603×120+3×70/362.166.175503×150+3×70/365.769.787103×185+3×95/368.772.7100203×240+3×120/376.880.8127503×300+3×150/382.086.01511012/20 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/345.548.531503×25+3×50/345.548.533003×35+3×25/348.351.336603×35+3×50/348.351.338003×50+3×25/352.556.545403×50+3×50/352.556.546803×70+3×35/355.759.754603×70+3×50/355.759.756903×95+3×50/361.465.467703×120+3×70/365.169.179803×150+3×70/368.772.791703×185+3×95/373.277.2107803×240+3×120/379.883.8132803×300+3×150/386.391.31607014/25 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/350.354.337503×25+3×50/350.354.339003×35+3×25/353.157.142903×35+3×50/353.157.144303×50+3×25/356.360.350203×50+3×50/356.360.351603×70+3×35/361.065.061903×70+3×50/361.065.064103×95+3×50/365.369.373403×120+3×70/369.073.085803×150+3×70/374.078.0100503×185+3×95/377.081.0114303×240+3×120/385.090.0144003×300+3×150/390.295.21686018/30kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/353.757.741603×25+3×50/353.757.743003×35+3×25/356.660.647303×35+3×50/356.660.648703×50+3×25/361.265.257003×50+3×50/361.265.258403×70+3×35/364.468.466803×70+3×50/364.468.469003×95+3×50/368.772.778603×120+3×70/373.877.893903×150+3×70/377.581.5106603×185+3×95/380.584.5120603×240+3×120/388.593.5150903×300+3×150/394.799.717820
Other supplier products
|
|
|
450/750V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (2-4 Cores) CU/XLPE/CUTO/PVC 450/750V Class 2Application:The cables are mainl... |
|
|
|
600/1000V LSZH Sheathed,Website:, AL. wire Armoured (single core) Application:The cables are mainly used in power stations, mass transit undergroun... |
|
|
|
UL Industrial Cables XHHW/CPE,Website:, 4-core, 600V,Type TC Power CableApplication and DescriptionXHHW/CPE, type TC Power Cable is used to supply ... |
|
|
|
PE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Multicore)RE-2Y(St)H 90°C / 500VSTANDARDSBasic design to EN 50288-7... |
|
|
|
N3GHSSYCY Medium-Voltage Cable VDE 0250 Part 605ApplicationsThese cables are used for the connection of mobile operatingequipment,Website:, in mine... |
供应产品
Same products