(N)TSCGEWOEU Medium-Voltage Fixed Installation Cable Without Fibre Optics

N)TSCGEWOEU Medium-Voltage Fixed Installation Cable Without Fibre OpticsApplicationsThese cables are used for laying alongside the conveyor belts (also for shiftable units)and on material handling equipment (even with continuous movementsuch as in cable booms or as connection between upperand lower car) and for connection of submersible pump units.StandardsBased on VDE 0250 Part 813ConstructionConductorsFlexible strandedcopper conductor,Website:, class 5 according to DIN VDE 0295.Inner Conductor LayerSemiconductive layer.InsulationEPR.Outer Conductor LayerSemiconductive layer.Earth ConductorSplit into three in the outer interstices.InnerSheathEPR.Outer SheathCM.Dimensions and Weight3.6/6 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/336.739.723203×25+3×50/340.643.628603×35+3×25/340.543.528603×35+3×50/342.345.332203×50+3×25/343.846.835003×50+3×50/343.846.836503×70+3×35/347.050.043603×70+3×50/349.753.750103×95+3×50/352.256.255503×120+3×70/355.959.966903×150+3×70/361.065.080303×185+3×95/364.068.093203×240+3×120/372.176.1119603×300+3×150/377.381.3142606/10 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/339.042.025203×25+3×50/341.444.429303×35+3×25/341.844.829803×35+3×50/343.646.633503×50+3×25/345.148.136403×50+3×50/345.148.137803×70+3×35/348.351.345003×70+3×50/348.351.347303×95+3×50/353.557.557103×120+3×70/357.261.268603×150+3×70/362.366.382103×185+3×95/365.369.395103×240+3×120/373.477.4121703×300+3×150/378.682.6145008.7/15 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/342.545.528503×25+3×50/344.247.232103×35+3×25/345.348.333403×35+3×50/345.348.334803×50+3×25/349.453.441803×50+3×50/349.453.443203×70+3×35/352.756.750903×70+3×50/352.756.753103×95+3×50/357.061.061603×120+3×70/362.166.175503×150+3×70/365.769.787103×185+3×95/368.772.7100203×240+3×120/376.880.8127503×300+3×150/382.086.01511012/20 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/345.548.531503×25+3×50/345.548.533003×35+3×25/348.351.336603×35+3×50/348.351.338003×50+3×25/352.556.545403×50+3×50/352.556.546803×70+3×35/355.759.754603×70+3×50/355.759.756903×95+3×50/361.465.467703×120+3×70/365.169.179803×150+3×70/368.772.791703×185+3×95/373.277.2107803×240+3×120/379.883.8132803×300+3×150/386.391.31607014/25 kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/350.354.337503×25+3×50/350.354.339003×35+3×25/353.157.142903×35+3×50/353.157.144303×50+3×25/356.360.350203×50+3×50/356.360.351603×70+3×35/361.065.061903×70+3×50/361.065.064103×95+3×50/365.369.373403×120+3×70/369.073.085803×150+3×70/374.078.0100503×185+3×95/377.081.0114303×240+3×120/385.090.0144003×300+3×150/390.295.21686018/30kVNumber of Cores×Nominal Cross SectionMinimium Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmkg/km3×25+3×25/353.757.741603×25+3×50/353.757.743003×35+3×25/356.660.647303×35+3×50/356.660.648703×50+3×25/361.265.257003×50+3×50/361.265.258403×70+3×35/364.468.466803×70+3×50/364.468.469003×95+3×50/368.772.778603×120+3×70/373.877.893903×150+3×70/377.581.5106603×185+3×95/380.584.5120603×240+3×120/388.593.5150903×300+3×150/394.799.717820
Other supplier products
|
|
|
S1 or S1/S5 RFOU(i) 250V Individual Shielding &Armour NEK606 Instrument cableApplications :These cables are flame retardant,Website:, low smoke, ha... |
|
|
|
UL Industrial Cables XHHW-2,Website:, AL armor, 600V Type MCApplication and Description600 Volt Type MC Cable is for use in aerial installations, d... |
|
|
|
NTMCWOEU Flexible Medium-Voltage Single Core Cable VDE 0250 Part 813ApplicationsThese cables are used for connection in switch-gear and for connect... |
|
|
|
UL Industrial Cables THHN / THWN-2 / MTWApplication and DescriptionType THHN/THWN conductors are primarily used in conduit for services,Website:, f... |
|
|
|
300/500V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (2-4 Cores) CU/XLPE/OS/PVC 300/500V Class 2Application:The cables are mainly... |
供应产品
Same products