600 1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

600/1000V XLPE Insulated,Website:, PVC Sheathed, Armoured Power Cables (Multicore)CU/XLPE/PVC 600/1000V Class 2CU/XLPE/PVC/SWA/PVC 600/1000V Class 2Application:The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.STANDARDS:Basic design adapted to IEC 60502-1; BS 5467FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)**EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)**EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.VOLTAGE RATING600/1000VCABLE CONSTRUCTIONConductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound.Inner Sheath(optional): PVC CompoundArmouring(optional): Galvanized Steel WireOuter Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.COLOUR CODEInsulation Colour as per BS7671With Earth ConductorWithout Earth Conductor2Cores-Brown, Blue3CoresYellow/Green, Brown, BlueBrown, Gray, Black4CoresYellow/Green, Brown, Gray, BlackBrown, Gray, Black, Blue5CoresYellow/Green, Brown, Gray, Black, BlueBrown, Gray, Black, Blue, BlackAbove 5 CoresYellow/Green, Black NumberedBlack NumberedSheath Colour: Black (other colors upon request)Physical AND THERMAL PROPERTIESTemperature range during operation: Max.90°C for XLPE250°C in short-circuit for 5secs max.Minimum bending radius: 8 x Overall Diameter (unarmoured cable)10 x Overall Diameter (armoured cable)CONSTRUCTION PARAMETERSConductorElectrical PropertiesConductor Operating Temperature : 90°CAmbient Temperature : 30°CCurrent-Carrying Capacities (Amp)No. of Core X Cross SectionNo./ Nominal Diameter of StrandsNominal Insulation ThicknessUnarmouredArmouredNominal Overall DiameterApprox. WeightDiameter Over Inner SheathArmour Wire DiameterNominal Overall DiameterApprox. Weightmm2No./mmmmmmmmmmmmmmkg/km7Cores7x1.57/0.530.712.422511.20.916.04907x2.57/0.670.713.830312.40.917.26027x47/0.850.715.542214.11.2519.887110Cores10x1.57/0.530.715.632514.31.2520.076110x2.57/0.670.717.542615.91.2521.894310x47/0.850.719.759718.51.2524.4121312Cores12x1.57/0.530.716.237014.81.2520.582712x2.57/0.670.718.148916.51.2522.4102012x47/0.850.720.369019.11.625.7146219Cores19x1.57/0.530.719.051617.41.624.0118619x2.57/0.670.721.372519.91.626.7149819x47/0.850.724.0103722.61.629.4193127Cores27x1.57/0.530.722.771221.31.628.1153727x2.57/0.670.725.5100423.91.630.9193327x47/0.850.728.8144527.21.634.4253237cores37x1.57/0.530.725.594123.91.630.7185637x2.57/0.670.728.7133426.91.633.9237237x47/0.850.732.5193231.12.039.3344848 Core48x1.57/0.530.729.0118627.51.634.6227648x2.57/0.670.732.9170631.32.039.6325248x47/0.850.737.3247935.72.044.24273Conductor cross- sectional areaReference Method 4 (enclosed in conduit in thermally insulating wall etc)Reference Method 3 (enclosed in conduit on a wall or in trunking etc)Reference Method 1 (clipped direct)Reference Method 11 (on a perforated cable tray, horizontal or vertical)Reference Method 12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c. flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or 3 c ables three phase2 cables, single- phase a.c. or d.c. or 3 cables three phase3 cables, trefoil 3-phase a.c.mm2AAAAAAAAAAA1..Voltage Drop (Per Amp Per Meter)Nominal Cross Section Area2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1 and 11 (clipped direct or on trays touching)Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1,Ref. Methods 1 and 1111 and 12 (in trefoil)(Flat and touching)1234567mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1..Current-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 1 (clipped direct)Reference Method 11 (on a perforated horizontal cable trayor Reference Method 13 [free air] )In single-way ductsLaid direct in groundone 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.123456789mm2AAAAAAAA1..Voltage Drop (Per Amp Per Meter)Conductor cross-sectional area2-core cable d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c.3 or 4 cables, 3-phase a.c.In ducts or in groundIn ducts or in ground123456mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1.531.031.027.031.025.02.519.019.016.019.015.0412.012.010.012.09.7
Other supplier products
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 9837ApplicationsThese cables have pairs laid up in a foil/braid screen,Website:, s... |
|
|
|
UL Industrial Cables THW/THW-2Application and DescriptionThe THW conductor is suitable for most current wiring solutions for residential,Website:, ... |
|
|
|
VDE Standard Industrial Cables H05Z-U/H07Z-U/H07Z-RApplication and DescriptionThese cables are designed for the internal wiring of switchboards and... |
|
|
|
Harmonized code Industrial Cables H05V2-K / H07V2-KApplication and DescriptionThese special heat-resistant flexible single-conductor hook-up wires ... |
|
|
|
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, CPE Jacket, 15kV to ICEA S-75-381ApplicationsThese cables are designed for connections... |
供应产品
Same products