300 500V XLPE Insulated, PVC Sheathed Power Cables (2-4 Cores)

300/500V XLPE Insulated,Website:, PVC Sheathed Power Cables (2-4 Cores) (CU/XLPE/PVC 300/500V Class 2)(CU/XLPE/PVC/SWA/PVC 300/500V Class 2)Application:The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.STANDARDS:Basic design adapted to IEC 60502-1; BS 5467FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)**EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)**EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.VOLTAGE RATING300/500VCABLE CONSTRUCTIONConductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Extruded cross-linked XLPE compound.Inner Sheath (optional): PVC CompoundArmouring (optional): Galvanized Steel WireOuter Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.COLOUR CODEInsulation Colour as per BS7671With Earth ConductorWithout Earth Conductor2Cores-Brown, Blue3CoresYellow/Green, Brown, BlueBrown, Gray, Black4CoresYellow/Green, Brown, Gray, BlackBrown, Gray, Black, Blue5CoresYellow/Green, Brown, Gray, Black, BlueBrown, Gray, Black, Blue, BlackAbove 5 CoresYellow/Green, Black NumberedBlack NumberedSheath Colour: Black (other colors upon request)Physical AND THERMAL PROPERTIESTemperature range during operation: Max.90°C for XLPE250°C in short-circuit for 5secs max.Minimum bending radius: 6 x Overall Diameter (unarmoured cable)10 x Overall Diameter (armoured cable)CONSTRUCTION PARAMETERSConductorNo. of Core X Cross SectionNo./Nominal Diameter of StrandsNominal Insulation ThicknessUnarmouredArmouredNominal Overall DiameterApprox. WeightDiameter Under ArmourArmour Wire DiameterNominal Overall DiameterApprox. WeightNoxmm2No./mmmmmmkg/kmmmmmmmkg/km2x1.57/0.530.506.5656.50.911.22462x2.57/0.670.507.3917.30.912.02922x47/0.850.508.41318.40.913.13603x1.57/0.530.506.9816.90.911.62753x2.57/0.670.507.81167.80.912.53313x47/0.850.509.01699.00.913.74134x1.57/0.530.507.61017.60.912.33094x2.57/0.670.508.61448.60.913.33804x47/0.850.509.92139.90.914.6479Electrical PropertiesConductor Operating Temperature : 90°CAmbient Temperature : 30°CCurrent-Carrying Capacities (Amp)Conductor cross- sectional areaReference Method 4 (enclosed in conduit in thermally insulating wall etc)Reference Method 3 (enclosed in conduit on a wall or in trunking etc)Reference Method 1 (clipped direct)Reference Method 11 (on a perforated cable tray, horizontal or vertical)Reference Method 12 (free air)Horizontal flat spacedVertical flat spacedTrefoil2 cables, single- phase a.c. or d.c.3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c3 or 4 cables, 3-phase a.c.2 cables, single- phase a.c. or d.c. flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or flat and touching3 or 4 cables, 3-phase a.c. flat and touching or trefoil2 cables, single- phase a.c. or d.c. or 3 c ables three phase2 cables, single- phase a.c. or d.c. or 3 cables three phase3 cables, trefoil 3-phase a.c.mm2AAAAAAAAAAA1..Voltage Drop (Per Amp Per Meter)Nominal Cross Section Area2 cables d.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1 and 11 (clipped direct or on trays touching)Ref. Methods 3 and 4 (enclosed in conduit etc, in or on a wall)Ref. Methods 1, 11 and 12 (in trefoil)Ref. Methods 1 and 11(Flat and touching)1234567mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1..Current-Carrying Capacities (Amp)Conductor crosssectional areaReference Method 1 (clipped direct)Reference Method 11 (on a perforated horizontal cable tray or Reference Method 13 [free air] )In single-way ductsLaid direct in groundone 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.one 2-core cable single phase a.c. or d.c.one 3-core or 4-core cable 3-phase a.c.123456789mm2AAAAAAAA1..Voltage Drop (Per Amp Per Meter)Nominal Cross Section Area2 cables d.c.2 cables, single- phase a.c.3 or 4 cables, 3-phase a.c.2 cables, single-phase a.c.3 or 4 cables, 3-phase a.c.In ducts or in groundIn ducts or in ground123456mm2mV/A/mmV/A/mmV/A/mmV/A/mmV/A/m1...7
Other supplier products
|
|
|
250V [FA-] MPYS,Website:, MPYCS, MPYCYSStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annealed... |
|
|
|
UL Industrial Cables RHH-RHW,Website:, DLO, 600V - 2000VApplication and DescriptionRHH-RHW, DLO (Diesel Locomotive Cable) type is designed for use ... |
|
|
|
Industrial Cables A07RN-FApplication and DescriptionThese cables are designed to provide high flexibility and have tde capacity to witdstand ozone,... |
|
|
|
NTMCWOEU Flexible Medium-Voltage Single Core Cable VDE 0250 Part 813ApplicationsThese cables are used for connection in switch-gear and for connect... |
|
|
|
UL Industrial Cables XHHW-2,Website:, AL armor, 600V Type MCApplication and Description600 Volt Type MC Cable is for use in aerial installations, d... |