H00V-D

German Standard Industrial Cables H00V-DApplication and DescriptionThese high flexible earth conductors are used for earthing of portable equipment and short circuiting. These cables perform a protective function in the live repair of high voltage power supply in railway systems,Website:, failing current equipment, alternating current systems and in networks of transmission and distribution. Because of that tdese are designated as safety cables. These earth cables offer special characteristics with low weights, high flexibility to a wide temperature range and the behavior in high temperature. The protective overall PVC jacket assure essential function for proper protection against mechanical and chemical stresses.Standard and ApprovalEN61138, VDE-0283 Part-3, DIN 46438 & DIN 46440, CE low voltage directive 73/23/EEC & 93/68/ EEC., ROHS compliantCable Construction- Extra fine bare copper strands- Strands to DIN VDE 0295, BS 6360, IEC 60228 and HD 383- Overall bare copper wire braid (for ESUY type)- PVC transparent jacket TM2- High stress resistance- Spark Test 6, 4 & 2 AWG: 5000V- Spark Test 1 & 2/0 AWG: 6000V- Spark Test 3/0 - 500 MCM: 8000VTechnical Characteristics- Working voltage: N/A - eartable_style_1g only- Test voltage: 2000 volts- Minimal bending radius: 12.0 x Ø- Temperature range: -5º C to +70º C- Flame retardant: IEC 60332.1- Insulation resistance: 20 MΩ x kmCable ParameterH00V-D (ESEU TYPE)AWGNO. OF CORES X NOMINAL CROSS SECTIONAL AREA # X MM²NOMINAL OVERALL DIAMETER MMNOMINAL COPPER WEIGHTKG/KMNOMINAL WEIGHTKG/KM6(4200/41)1 x 169./38)1 x 2510./38)1 x 3512./38)1 x 5014.25856702/0(8918/38)1 x 7016.88209053/0(12100/38)1 x 9519.8109012204/0(15300/38)1 x 12021.MCM(19152/38)1 x MCM(23580/38)1 x 18527.MCM(30600/38)1 x H00V-D (ESY TYPE)AWGNO. OF CORES X NOMINAL CROSS SECTIONAL AREA # X MM²NOMINAL OVERALL DIAMETER MMNOMINAL COPPER WEIGHTKG/KMNOMINAL WEIGHTKG/KM6(525/32)1 x 168./32)1 x 2510./32)1 x 3512./32)1 x 5014.04805752/0(2254/32)1 x 7017.26728103/0(3087/32)1 x 9519.591210804/0(3822/32)1 x 12022.MCM(4802/32)1 x 15025.414401680
Other supplier products
|
|
|
450/750V LSZH Sheathed,Website:, Screened (2-4cores) Application:The cables are mainly used in power stations, mass transit underground passenger s... |
|
|
|
300/500V XLPE Insulated,Website:, PVC Sheathed Power Cables (2-4 Cores) (CU/XLPE/PVC 300/500V Class 2)(CU/XLPE/PVC/SWA/PVC 300/500V Class 2)Applica... |
|
|
|
Fire resistant RG59 B/U Coaxial cables RG59 B/U FRApplication:The cables are designed for CCTV,Website:, security, smoke detection and evacuation m... |
|
|
|
KX Series Coaxial Cables 50 Ω/75 Ω IEC60092ApplicationThese radio frequency cables are suitable for high frequency data transmission (communication... |
|
|
|
450/750V XLPE Insulated,Website:, PVC Sheathed Power Cables (Multicore) CU/XLPE/PVC 450/750V Class 2Application:The cables are mainly used in power... |
供应产品
Same products