Fire Resistant UTP CAT5 Data Cables

Fire Resistant UTP CAT5 Data Cables FR-CAT5UTP4P24Application:The cables are desgined for structure wiring,Website:, compatible with all known connection systems according to EN 50173. Based on the design for structured wiring (found in IEC 61156 and BS EN 50288), this cable brings together high frequency data transmission and circuit integrity in four pair cable that will continue to transmit data even when being directly attacked by fire.STANDARDS:Basic design to EN 50173VOLTAGE RATING:60VFIRE PERFORMANCECircuit IntegrityIEC 60331-23; BS 6387 CWZ; DIN VDE 0472-814(FE180);CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)System circuit integrityDIN 4102-12, E30 depending on lay systemFlame Retardance (Single VerticalWire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.CABLE CONSTRUCTIONConductors: Plain annealed copper wire, solid according to IEC(EN) 60228 class 1.Insulation: PE wrapped with fire resistant silicone rubber compound type EI2 as per BS 7655-1.1.Twisted Pairs: Insulated conductors are twisted into pairs with varying lay length to minimizecrosstalk.Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimizecrosstalk. Two-pair cable had four cores laid in quad formation.Cabling: Pairs are cabled together in concentric layers.Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZHcompound type SW2-SW4 as per BS 7655-2.6 can be offered.)Physical AND THERMAL PROPERTIESTemperature range during operation (fixed state): -5℃ - +50℃Temperature range during installation (mobile state): -20℃ - +90℃Minimum bending radius: 8 x Overall DiameterElectrical PropertiesCharacteristic Impedance100 Ohm±15%Nominal Velocity of Propagation (NVP)69%Max. Dc Resistance9.38 Ohm/100mMax. Resistance Unbalance5%Max. Mutual Capacitance:5.6 nF/100mMaximum Capacitance Unbalance330 pF/100mMax. Propagation Delay Skew30 ns/100mMax. Propagation Delay536 ns/100m@100 mhzMax. Pulling Load80NTransmission PropertiesFREQ (MHz)NEXT(dB/100m)Minimum Value/Typical Value/ Standard ValueIL (dB/100m)SRL (dB/100m)Minimum Value/Typical Value/ Standard Value164.0/71.0/62.02.024.5/26.0/23.0455.0/62.0/53.04.024.5/26.0/23.0849.5/57.0/48.05.724.5/26.0/23.01049.0/56.0/47.06.424.5/26.0/23.01644.9/52.0/44.08.224.5/26.0/23.02042.5/48.0/42.09.224.5/26.0/23.02542.0/48.0/41.010.324.5/26.0/23.031.2540.6/48.0/39.011.622.5/24.0/21.062.536.1/43.0/35.016.919.5/22.0/18.010034.0/40.0/32.021.817.5/20.0/16.0CONSTRUCTION PARAMETERSCable CodeConductorDiameterNominal Insulation ThicknessNominal Overall DiametermmmmmmFR-CAT5UTP4P240.50.255.3
Other supplier products
|
|
|
Type 450 3.3 to 33KV to AS/NZS 2802ApplicationsThese cables are suitable for supply of power to a wide range of applications,Website:, from draglin... |
|
|
|
Type G Two-Conductor Flat Portable Power Cable 2kVApplicationsThese flat parallel cables are designed for use on D.C. off-track mining equipment,We... |
|
|
|
VDE Standard Industrial Cables H03V2V2-F/H03V2V2H2-F Application and DescriptionThese cables are suitable for domestic premises,Website:, kitchen, ... |
|
|
|
Fire Resistant RG11 A/U Coaxial Cables RG11 A/U FRApplication:The cables are designed for CCTV,Website:, security, smoke detection and evacuation m... |
|
|
|
Type SHD-CGC Three-Conductor Round Portable Power Cable 2kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for applications such as ... |
供应产品
Same products