225V SR Insulated LSZH Sheathed Fire Alarm Cables
225V SR Insulated & LSZH Sheathed Fire Alarm CablesJE-H(St)H…Bd FE180 E30 (CU/SR/OS/LSZH 225V Class 1)JE-H(St)HSWAH…Bd FE180 E30 (CU/SR/OS/LSZH/SWA/LSZH 225V Class 1)Application:The cables are used for the internal wiring of building when the circuit integrity during fire is paramount. The cables are intended for use in fire fighting plants with special ceramized silicone insulation,Website:, with and without aluminum foil and LSZH outer sheath.
The fire alarm cables with 30 to 90 minutes circuit integrity should be used for control voltages and data transfer in alarm and fire alarm systems, where a system circuit integrity E30/E60/E90 depending on lay system in accordance with DIN 4102-12 is required. The circuit integrity is guaranteed with a test voltage of 110V.STANDARDS:Basic design to VDE 0815FIRE PERFORMANCECircuit IntegrityIEC 60331-23; BS 6387 CWZ; DIN VDE 0472-814(FE180);CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)System circuit integrityDIN 4102-12, E30 depending on lay systemFlame Retardance (Single VerticalWire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2;VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE *Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE ; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE ; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE &2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.CABLE CONSTRUCTION Conductors: Solid annealed bare or tinned copper sized 0.6/0.8/0.9mm as per class 1 of VDE 0295/IEC 60228.Insulation: Silicone Rubber compound as per DIN VDE 0266.Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimizecrosstalk. Two-pair cable had four cores laid in quad formation.Cabling: Pairs are cabled together.In cables with 8 pairs or more, 4 pairs are assembled to form abunch, and the bunches are then cabled together.Cable Core Assembly: The twisted pairs are stranded to the core in layers.Core Wrapping: One or more non hygroscopic polyester tapes are helically or longitudinally laid withan overlap prior to sheathing.Screen: A laminated Aluminum/Polyester tape is placed in contact with solid copper 0.6mm or0.8mm drain wire.Inner Sheath(optional): PE or thermoplastic LSZH compound type.Armour (optional): Either corrugated steel tape armour or galvanized steel wire is applied overan inner polyethylene sheath. For steel tape armour, the 0.15mm thick steel tape is coated with acopolymer and applied with an overlap. For steel wire armour, single layer of galvanized steel wirearmour is applied.Ripcord: Nylon ripcord may be placed parallel to the cores to facilitate sheath removal.Drain Wire: A solid tinned earth/continuity wire shall be laid longitudinally for screened cables.Outer Sheath: Thermoplastic LSZH compound HM2 as per DIN VDE 0207-24 .COLOUR CODEQuad colour in each bundle:Pair 1: Blue-Red Pair 2: Green-Yellow Pair 3: Green-Brown Pair 4: White-BlackThe individual bundles are identified by a numbered helix.TYPE CODEJE- Fire alarm cable H Halogen free & zero halogenBd Unit stranding. (St) Static shield of Aluminum tapeFE180 Insulation integrity (950°C 180 minutes) E30 30 minutes system circuit integritySTA Corrugated steel tape SWA Steel wire armourSWB Steel wire braidPhysical AND THERMAL PROPERTIESTemperature range during operation (fixed state): -30°C – +90°CTemperature range during installation (mobile state): -20°C – +50°CMinimum bending radius: 8 x Overall Diameter (unarmoured cable)10 x Overall Diameter (armoured cables)Electrical PROPERTIESConductor Diametermm0.60.80.9Conductor Sizemm20.2830.50.312Maximum Conductor Resistance Loop Resistance Insulation Resistance @500V DC Average Attenuation Mutual Capacitance Capacitance Unbalance K1 pair-to-pairpF/100m200200200Working VoltageV225225225Nominal Insulation Thicknessmm0.30.40.45Nominal Insulated Conductor Diametermm1.21.61.7CONSTRUCTION PARAMETERSVDE CODE: JE-SH(St)H…x2x0.8 Bd FE180/E30Cable CodeNo.ofPairsNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox.Weightmmmmmmkg/km0.8mm Conductor, 1.6mm Insulated WireJE-H(St)H...1x2x0.8 Bd FE180/E3010.41.06.046JE-H(St)H...2x2x0.8 Bd FE180/E3020.41.06.661JE-H(St)H...4x2x0.8 Bd FE180/E3040.41.08.8104JE-H(St)H...6x2x0.8 Bd FE180/E3060.41.010.8160JE-H(St)H...8x2x0.8 Bd FE180/E3080.41.012.8218JE-H(St)H...10x2x0.8 Bd FE180/E30100.41.213.1220JE-H(St)H...12x2x0.8 Bd FE180/E30120.41.213.5235JE-H(St)H...16x2x0.8 Bd FE180/E30160.41.214.7297JE-H(St)H...20x2x0.8 Bd FE180/E30200.41.216.1367JE-H(St)H...24x2x0.8 Bd FE180/E30240.41.418.1440JE-H(St)H...30x2x0.8 Bd FE180/E30300.41.420.1645JE-H(St)H...32x2x0.8 Bd FE180/E30320.41.420.6645JE-H(St)H...40x2x0.8 Bd FE180/E30400.41.422.5656JE-H(St)H...50x2x0.8 Bd FE180/E30500.41.624.3840VDE CODE: JE-SH(St)HSWAH…x2x0.6/0.8/0.9 Bd FE180/E30Cable CodeNo. ofPairsNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox.Weightmmmmmmkg/km0.6mm Conductor,1.2mm Insulated WireJE-H(St)HSWAH...2x2x0.6 Bd FE180/E3020.31.0/1.812.1305JE-H(St)HSWAH...3x2x0.6 Bd FE180/E3030.31.0/1.812.6325JE-H(St)HSWAH...6x2x0.6 Bd FE180/E3060.31.0/1.812.6380JE-H(St)HSWAH...8x2x0.6 Bd FE180/E3080.31.0/1.814.6415JE-H(St)HSWAH...10x2x0.6 Bd FE180/E30100.31.0/1.816.5450JE-H(St)HSWAH...12x2x0.6 Bd FE180/E30120.31.0/1.817.0500JE-H(St)HSWAH...20x2x0.6 Bd FE180/E30200.31.0/1.820.5580JE-H(St)HSWAH...25x2x0.6 Bd FE180/E30250.31.0/1.821.5940JE-H(St)HSWAH...30x2x0.6 Bd FE180/E30300.31.0/1.822.513000.8mm Conductor, 1.6mm Insulated WireJE-H(St)HSWAH...2x2x0.8 Bd FE180/E3020.41.0/1.814.0415JE-H(St)HSWAH...3x2x0.8 Bd FE180/E3030.41.0/1.814.0425JE-H(St)HSWAH...6x2x0.8 Bd FE180/E3060.41.0/1.815.0485JE-H(St)HSWAH...8x2x0.8 Bd FE180/E3080.41.0/1.817.5520JE-H(St)HSWAH...10x2x0.8 Bd FE180/E30100.41.2/1.819.0540JE-H(St)HSWAH...12x2x0.8 Bd FE180/E30120.41.2/1.820.5600JE-H(St)HSWAH...20x2x0.8 Bd FE180/E30200.41.4/1.824.51050JE-H(St)HSWAH...25x2x0.8 Bd FE180/E30250.41.4/1.827.01250JE-H(St)HSWAH...30x2x0.8 Bd FE180/E30300.41.4/1.828.514500.9mm Conductor, 1.8mm Insulated WireJE-H(St)HSWAH...10x2x0.9 Bd FE180/E30100.451.2/1.819.7600JE-H(St)HSWAH...15x2x0.9 Bd FE180/E30150.451.2/1.823.01020JE-H(St)HSWAH...20x2x0.9 Bd FE180/E30200.451.4/1.825.31160JE-H(St)HSWAH...25x2x0.9 Bd FE180/E30250.451.4/1.827.31330JE-H(St)HSWAH...30x2x0.9 Bd FE180/E30300.451.4/1.829.31520
Other supplier products
|
|
wNF M 87-202 EISFAPPLICATIONThese NF M 87-202 EISF instrumentation cables are used to transmit analogue or digital signals in easurement and proces... |
|
|
NF M 87-202 EGPFAPPLICATIONThese NF M 87-202 EGPF instrumentation cables are used for safety extra-low use in petroleum and petrochemical units par... |
|
|
UL Industrial Cables XHH / XHHW-2Application and DescriptionThe XHH conductor is suitable for most current wiring solutions for residential,Website... |
|
|
P3 or P3/P10 RFOU/TFOU 6/10KV NEK606 MV CableApplicationsThese cables are flame retardant,Website:, low smoke, halogen free and mud resistant, used... |
|
|
UL Industrial Cables XHHW/PVC,Website: TC Power CableApplication and DescriptionXHHW/PVC, type TC Power Cable is used to supply power to motors, or... |
供应产品
Same products