Type SHD-GC Three-Conductor Round Portable Power Cable, TPU Jacket 8kV To ICEA S-75-381

Type SHD-GC Three-Conductor Round Portable Power Cable,Website:, TPU Jacket 8kV to ICEA S-75-381ApplicationsThese heavy duty cables are designed for heavy mobile equipment such as drag lines, shovels, dredges, drills and for power feeders.StandardsICEA S-75-381/NEMA WC 58ASTM B 172ASTM B 33CAN/CSA C22.2 No. 96ConstructionConductorsStranded annealed tinned copper conductor.Conductor ShieldSemi-conducting layer.InsulationEthylene Propylene Rubber (EPR).Insulation ShieldConducting tape + Tinned copper/textile braid.Ground Check ConductorTinned copper with a yellow polypropylene insulation.Grounding ConductorTinned copper conductor.JacketThermoplastic Polyurethane (TPU) Jacket, black.OptionsOther jacket materials such as CSP/PCP/NBR/PVC are available upon request.
Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.Mechanical and Thermal PropertiesMinimum Bending Radius: 6×ODMaximum Operating Temperature: +90℃Dimensions and Weight:ConstructionNo. of StrandsGrounding Conductor SizeGround Check Conductor SizeNominal Insulation ThicknessNominalJacketThicknessNominalOverallDiameterNominal WeightAmpacityNo. of cores×AWG/kcmil-AWG/kcmilAWG/kcmilinchmminchmminchmmlbs/kftkg/kmA3×4259880.1503.80.2055.21.9449.×2259680.1503.80.2205.62.1253.×1259580.1503.80.2205.62.2156.×1/0266480.1503.80.2205.62.3258.×2/0323380.1503.80.2356.02.4662.×3/0418280.1503.80.2506.42.6266.×4/0532180.1503.80.2506.42.7569.×2506271/060.1503.80.2506.42.8973.×3508882/060.1503.80.2807.13.2181.×50012214/060.1503.80.2957.53.5690.Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.
Other supplier products
|
|
|
300/500V Mica+XLPE Insulated & LSZH Sheathed Fire Alarm Cables(CU/MICA+XLPE/OS/LSZH 300/500V Class 2 )Application:The cables are designed,Website:,... |
|
|
|
German Standard Industrial Cables N2XFGY/ NA2XFGYApplication and DescriptionN2XFGY/ NA2XFGY cables are for lying in eartd,Website:, indoors, in duc... |
|
|
|
NF M 87-202 EGSFAPPLICATIONThese NF M 87-202 EGSF instrumentation cables are used for safety extra-low use in petroleum and petrochemical units par... |
|
|
|
XLPE Insulated,Website:, LSZH Sheathed & Overall Screened Instrumentation Cables (Multitriple)RE-2X(St)H 90°C / 300 VSTANDARDSBasic design to EN 50... |
|
|
|
Fire Resistant Central Loose Tube Optical Fiber CablesApplicationThese optical fiber cables are designed to data transmission in ship and specially... |