NYCWY

German Standard Industrial Cables NYCWYApplication and DescriptionNYCWY Power cables is for energy supply,Website:, preferably used for underground laying, especially in subscriber networks, power station as well as control impulses and test data. Overall, where increased electrical and also mechanical protection are required. These cables are installed in open air, in underground, in water, indoors and in cable ducts. The corrugated concentric conductor (CW) is allowed to use as neutral, protective or eartd conductor. Simultaneously, tdis also is permitted to apply as a screen for example eartded-connected protection against contact. Due to tde typical construction of corrugated concentric conductors (Ceander), are possible to obtain many more cable joints, witdout cutting any conductor. In tdat way tde operating reliability is guaranteed.Standard and ApprovalVDE0276 part 603, CENELEC HD603 S1, IEC 60502Cable Construction- Plain copper conductors solid or stranded versions, conductor types10-16 mm² round, solid conductors (re) alt.10-25 mm², stranded conductor (rm),35-240 mm², sector shaped conductor, stranded (sm)- to DIN VDE 0295 cl. 1 or cl. 2, BS 6360 cl. 1, IEC 60228 and HD 383- PVC insulation DIV4 to HD 603.1- Color coded to DIN VDE 0293-308, 0276 part 603 or HD 186- PVC bedding- Concentric conductor: ceander shaped copper wires and helical copper tape- PVC outer jacket DMV5 to HD 603.1Technical Characteristics- Working voltage: 600/1000 volts- Test voltage: 4000 volts- Flexing bending radius: 15 x Ø- Static bending radius: 12 x Ø- Flexing temperature: -5º C to +50º C- Fixed installation temperature: - 40º C to +70º C- Short circuit temperature: +160º C- Flame retardant: IEC 60332.1- Insulation resistance: 100 MΩ x kmCable ParameterAWGNO. OF CORES XNOMINAL CROSSSECTIONAL AREA# X MM²STRANDED CONDUCTOR TYPENOMINALOVERALL DIAMETER MMNOMINAL COPPER WEIGHT KG/KMNOMINAL CABLE WEIGHT KG/KM82 x 10.0re / 10. x 16.0re / 16.021.548985042 x 25.0rm / 25.024.5763121083 x 10.0re / 10.019.540873063 x 16.0re / 16. x 25.0rm / 16. x 25.0rm / 25. x 35.0sm / 35.027. x 35.0sm / 16. x 50.0sm / 50.029. x 50.0sm / 25./03 x 70.0sm / 70./03 x 70.0sm / 35./03 x 95.0sm / 95.038.5379145503/03 x 95.0sm / 50./03 x 120.0sm / 70./03 x 120.0sm / 120.mcm3 x 150.0sm / 70.mcm3 x 150.0sm / 150.mcm3 x 185.0sm / 95.mcm3 x 185.0sm / 185.mcm3 x 240.0sm / 120. x 10.0re / 10.020.550489064 x 16.0re / 16.023.5796125044 x 25.0rm / 16. x 35.0sm / 16. x 50.0sm / 25./04 x 70.0sm / 35./04 x 95.0sm / 50.043.5420850004/04 x 120.0sm / 70.mcm4 x 150.0sm / 70.mcm4 x 185.0sm / 95.mcm4 x 240.0sm / 120.062.
Other supplier products
|
|
|
VDE Industrial Cables H05V-R/H07V-RApplication and DescriptionThese cables are preferably for installation indoors,Website:, in cable ducts and in ... |
|
|
|
NTMCGCWOEU Flexible Medium-Voltage Single Core Cable VDE 0250 Part 813ApplicationsThese cables are used for connection in switch-gear and for conne... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8315ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
F6 AICI NEK606 optical fibre cableApplications :These optical fibre cables are fire resistant,Website:, flame retardant, low smoke and halogen free... |
|
|
|
250V [FA-] MPY-S,Website:, MPYC-S, MPYCY-SStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CONSTRUCTIONConductorMTinned annea... |
供应产品
Same products