Type G-GC Three-Conductor Flat Portable Power Cable 2kV ICEA S-75-381

Type G-GC Three-Conductor Flat Portable Power Cable 2kV ICEA S-75-381ApplicationsThese flat parallel cables are designed for use on ACmining equipment,Website:, such as A.C. shuttle cars, drills, cutting and loading machines.StandardsICEA S-75-381/NEMA WC 58ASTM B 172ASTM B 33CAN/CSA C22.2 No. 96ConstructionConductorsStranded annealed tinned copper conductor.InsulationEthylene Propylene Rubber (EPR).Ground Check ConductorTinned copper conductor with a yellow insulation.Grounding ConductorTinned copper conductor with an optional green outer covering.ReinforcementSynthetic yarn.JacketHeavy-duty/extra-heavy-duty Chlorinated Polyethylene (CPE), black. (Cables having a nominal outside diameter of more than 2.0 inches require extra-heavy-duty jackets.)OptionsOther jacket materials such as CSP/PCP/NBR/PVC are available upon request.Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.Mechanical and Thermal PropertiesMinimum Bending Radius: 6×ODMaximum Operating Temperature: +90℃Dimensions and Weight:
ConstructionNo. of StrandsGrounding Conductor SizeGround Check Conductor SizeNominal Insulation ThicknessNominal Jacket ThicknessNominal Overall Diameter Height×WidthNominal WeightAmpacityNo. of cores×AWG/kcmil-AWG/kcmilAWG/kcmilinchmminchmminchmmlbs/kftkg/kmA3×6133880.061.50.0952.40.66×1.6716.8×42.×4259780.061.50.0952.40.72×1.8718.3×47.×3259660.061.50.1102.80.78×2.0819.8×52.×2259560.061.50.1102.80.85×2.2321.6×56.×1259460.082.00.1253.20.96×2.5024.4×63.×1/0259350.082.00.1403.61.01×2.6725.6×67.×2/0329250.082.00.1403.61.09×2.8627.7×68.×3/0413150.082.00.1553.91.18×3.1230.0×79.×4/05321/050.082.00.1553.91.24×3.3031.5×83.Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.
Other supplier products
|
|
|
XLPE Insulated 6.35/11KV & 12.7/22KV AS/NZS 1972/1125/3808ApplicationsThese cables are used as HV feeder cables in fixed conditions.StandardsAS/NZS... |
|
|
|
Harmonized Code Industrial Cables H05G-U/H07G-U/RApplication and DescriptionThese cables are recommended for tde internal wiring of switchboards an... |
|
|
|
PE Insulated,Website:, LSZH Sheathed, Individual & Overall Screened, Armoured Instrumentation Cables (Multitriple)RE-2Y(St)HSWAH-TiMF 70°C / 300 VS... |
|
|
|
Type SHD-PCG Three-Conductor Portable Power Cable 5kV ICEA S-75-381ApplicationsThese heavy duty cables are designed for use on longwall shearers,We... |
|
|
|
UL Industrial Cables AL-XHHW-2 Power Cable,Website:, CT RatedApplication and DescriptionType XHHW-2 conductors are primarily used in conduit or rec... |
供应产品
Same products