H07RN-F/A07RN-F 450/750V Harmonized Rubber Cables

H07RN-F/A07RN-F 450/750V Harmonized Rubber CablesApplicationsThese cables are designed for the connection of heating units,Website: tools, mobile equipmentand machines, e.g. vulcanisation plates,hand-operated equipment,transportable motors etc., undernormal mechanical loads in dry anddamp areas, outdoors and in explosionhazard areas, as well as in industrialand agricultural applications and onbuilding sites.StandardsDIN VDE 0282 Part1 and Part 4HD 22.1HD 22.4ConstructionConductorsStrandedcopper conductor, class 5 according to DIN VDE 0295/HD 383 S2.InsulationRubbertype EI4 according to DIN VDE 0282 Part 1/HD 22.1.Inner Sheath(for ≥ 10 mm² ormore than 5 cores)NR/SBR rubbertype EM1.Outer SheathCR/PCP rubber type EM2.Dimensions and Weight:Number of Cores×Nominal Cross SectionInsulation ThicknessThickness of Inner SheathThickness of Outer SheathMinimum Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmmmmmmmkg/km1×1.50.8-1.45.76.7602×1.50.8-1.58.510.51203G1.50.8-1.69.211.21704G1.50.8-1.710.212.52105G1.50.8-1.811.213.52607G1.50.81.01.614.017.036012G1.50.81.21.717.620.551519G1.50.81.42.120.726.379524G1.50.81.42.124.328.59201×2.50.9-1.46.37.5752×2.50.9-1.710.212.51703G2.50.9-1.810.913.02304G2.50.9-1.912.114.52905G2.50.9-2.013.316.03607G2.50.91.11.717.020.051012G2.50.91.21.920.623.574019G2.50.91.52.224.430.9119024G2.50.91.62.328.833.015251×41.0-1.57.28.51002×41.0-1.811.814.51953G41.0-1.912.715.03054G41.0-2.014.017.04005G41.0-2.215.619.05051×61.0-1.67.99.51302×61.0-2.013.116.02853G61.0-2.114.117.03804G61.0-2.315.719.05505G61.0-2.517.521.06601×101.2-1.89.511.51952×101.21.21.917.721.55653G101.21.32.019.122.57154G101.21.42.020.924.58755G101.21.42.222.927.010951×161.2-1.910.813.02802×161.21.32.020.223.57953G161.21.42.121.825.510404G161.21.42.223.828.012805G161.21.52.426.431.016101×251.4-2.012.715.04054G251.41.62.228.933.018905G251.41.72.732.036.023351×351.4-2.214.317.05454G351.41.72.732.536.525055G351.41.82.835.039.527181×501.6-2.416.519.57304G501.61.92.937.742.033505G501.62.13.141.046.038041×701.6-2.618.622.09554G701.62.03.242.747.047851×951.8-2.820.824.011354G951.82.33.648.454.060901×1201.8-3.022.826.515604G1201.82.43.653.059.075505G1201.82.84.059.065.082901×1502.0-3.225.229.019254G1502.02.63.958.064.084951×1852.2-3.427.631.522304G1852.22.84.264.071.098501×2402.4-3.530.635.029451×3002.6-3.633.538.034951×6303.0-4.145.551.07020
Other supplier products
|
|
|
UL Industrial Cables XHHW/PVC Jacket,Website:, Power Cable, CT RatedApplication and DescriptionXHHW/PVC conductors are primarily used in conduit, c... |
|
|
|
CAN BUS CABLES 120ΩApplicationThese cables are dedicated to the shipbuilding industry.StandardsIEC 60092-350/351/352/353/359/370/376IEC 60332-1-2IE... |
|
|
|
300/500V SR Insulated & Overall screened fire resistant control cables (2-4 cores & Multicores)(PH30/60) (CU/SR/OS/LSZH 300/500V Class 1)(PH30/60) ... |
|
|
|
250V [FA-] TTY-S,Website:, TTYC-S, TTYCY-S [FA-] TTPY-S, TTPYC-S, TTPYCY-SStandards:JISC 3410-1999IEC 60332-1IEC 60332-3 Cat.A(for FA-type)CABLE CO... |
|
|
|
0.6/1 kV Fire Barriers + HEPR Insulated,Website:, LSOH (SHF1) Sheathed, Screened Fire Resistant Power & Control Cables (Single Core)ApplicationThes... |