H07RN-F/A07RN-F 450/750V Harmonized Rubber Cables

H07RN-F/A07RN-F 450/750V Harmonized Rubber CablesApplicationsThese cables are designed for the connection of heating units,Website: tools, mobile equipmentand machines, e.g. vulcanisation plates,hand-operated equipment,transportable motors etc., undernormal mechanical loads in dry anddamp areas, outdoors and in explosionhazard areas, as well as in industrialand agricultural applications and onbuilding sites.StandardsDIN VDE 0282 Part1 and Part 4HD 22.1HD 22.4ConstructionConductorsStrandedcopper conductor, class 5 according to DIN VDE 0295/HD 383 S2.InsulationRubbertype EI4 according to DIN VDE 0282 Part 1/HD 22.1.Inner Sheath(for ≥ 10 mm² ormore than 5 cores)NR/SBR rubbertype EM1.Outer SheathCR/PCP rubber type EM2.Dimensions and Weight:Number of Cores×Nominal Cross SectionInsulation ThicknessThickness of Inner SheathThickness of Outer SheathMinimum Overall DiameterMaximum Overall DiameterNominal WeightNo.×mm²mmmmmmmmmmkg/km1×1.50.8-1.45.76.7602×1.50.8-1.58.510.51203G1.50.8-1.69.211.21704G1.50.8-1.710.212.52105G1.50.8-1.811.213.52607G1.50.81.01.614.017.036012G1.50.81.21.717.620.551519G1.50.81.42.120.726.379524G1.50.81.42.124.328.59201×2.50.9-1.46.37.5752×2.50.9-1.710.212.51703G2.50.9-1.810.913.02304G2.50.9-1.912.114.52905G2.50.9-2.013.316.03607G2.50.91.11.717.020.051012G2.50.91.21.920.623.574019G2.50.91.52.224.430.9119024G2.50.91.62.328.833.015251×41.0-1.57.28.51002×41.0-1.811.814.51953G41.0-1.912.715.03054G41.0-2.014.017.04005G41.0-2.215.619.05051×61.0-1.67.99.51302×61.0-2.013.116.02853G61.0-2.114.117.03804G61.0-2.315.719.05505G61.0-2.517.521.06601×101.2-1.89.511.51952×101.21.21.917.721.55653G101.21.32.019.122.57154G101.21.42.020.924.58755G101.21.42.222.927.010951×161.2-1.910.813.02802×161.21.32.020.223.57953G161.21.42.121.825.510404G161.21.42.223.828.012805G161.21.52.426.431.016101×251.4-2.012.715.04054G251.41.62.228.933.018905G251.41.72.732.036.023351×351.4-2.214.317.05454G351.41.72.732.536.525055G351.41.82.835.039.527181×501.6-2.416.519.57304G501.61.92.937.742.033505G501.62.13.141.046.038041×701.6-2.618.622.09554G701.62.03.242.747.047851×951.8-2.820.824.011354G951.82.33.648.454.060901×1201.8-3.022.826.515604G1201.82.43.653.059.075505G1201.82.84.059.065.082901×1502.0-3.225.229.019254G1502.02.63.958.064.084951×1852.2-3.427.631.522304G1852.22.84.264.071.098501×2402.4-3.530.635.029451×3002.6-3.633.538.034951×6303.0-4.145.551.07020
Other supplier products
|
|
|
Type MP-GC Three-Conductor Mine Power Feeder Cable,Website:, PVC Jacket, 5kV ICEA S-75-381ApplicationsThese cables are designed for connections bet... |
|
|
|
Multipair Overall Foil & Braid Screened Cables-Belden Equivalent 8335ApplicationsThese cables have pairs laid up in a foil/braid screen. These cabl... |
|
|
|
Type SHD-GC Three-Conductor Round Portable Power Cable,Website:, TPU Jacket 8kV to ICEA S-75-381ApplicationsThese heavy duty cables are designed fo... |
|
|
|
Multicore Unscreened Armoured Cables-Belden Equivalent 28538ApplicationsThese multicore unscreened armoured cables are Type MC Metal Clad cables.Co... |
|
|
|
P7 or P7/P14 BFOU 6/10kV Fire resistant NEK606 MV cableApplications :These cables are fire resistant,Website:, flame retardant, low smoke, halogen ... |
供应产品
Same products