Type 241 1.1 To 11KV To AS/NZS 1802

Type 241 1.1 to 11KV to AS/NZS 1802ApplicationsThese cables are designed for various uses,Website:, including main feeder cable for continuous miners, pump cable, and power supply cable. Overall semiconductive screen provides protective earth contact for any object breaching the sheath prior to contact with power conductors.StandardsAS/NZS 1802:2003AS/NZS 1125AS/NZS 3808AS/NZS 5000.1Construction3×ConductorsFlexible stranded tinned annealed copper conductor.Conductor ScreenSemiconductive compound (for cables having a voltage rating of 3.3/3.3kV and above).InsulationEPR.Insulation ScreenSemiconductive elastomer.Cradle SeparatorSemiconductive PCP.Overall Core ScreenSemiconductive PCP filling and covering.3×Interstitial Earth ConductorSemiconductive PCP covered flexible stranded tinned copper conductor.1×Central Extensible PilotEPR covered flexible stranded tinned copper conductor.Textile ReinforcementOpen-weave braid reinforcement.SheathHeavy duty PCP sheath.Heavy duty CPE/CSP sheath can be offered upon request.Dimensions and WeightNominal Conductor AreaStrandSizeInsulation ThicknessEarth ConductorPilot ConductorThickness of Sheath IncludingSC PCPLayerNominal Overall DiameterNominal WeightStrandSizeThickness of CoveringStrandSizeThickness of Coveringmm2No/mmmmNo/mmmmNo/mmmmmmmmkg/100mType 241.1684/0.301.518/0.301.024/0.200.83.828.51061077/0.401.527/0.301.024/0.200.83.831.112716126/0.401.642/0.301.024/0.200.83.934.116425209/0.401.666/0.301.024/0.200.84.237.920835285/0.401.690/0.301.024/0.200.84.441.225450380/0.401.7120/0.301.040/0.200.84.945.932870203/0.671.839/0.671.040/0.200.85.352.248095259/0.672.039/0.671.040/0.200.85.856.7600120336/0.672.142/0.671.240/0.200.86.362.7710150427/0.672.354/0.671.240/0.200.86.768.3865185518/0.672.563/0.671.440/0.200.87.374./0.672.877/0.671.440/0.200.88.083./0.673.098/0.671.440/0.200.88.791.21600Type 241.316126/0.403.042/0.301.024/0.200.85.043.824925209/0.403.066/0.301.024/0.200.85.347.731535285/0.403.090/0.301.024/0.200.85.651.137650380/0.403.0120/0.301.240/0.200.86.055.245070203/0.673.039/0.671.240/0.200.86.460.357695259/0.673.048/0.671.240/0.200.86.863.8675120336/0.673.060/0.671.240/0.200.87.269.1810150427/0.673.077/0.671.240/0.200.87.673.8952185518/0.673.091/0.671.440/0.200.88.079./0.673.0112/0.671.440/0.200.88.686./0.673.0144/0.671.440/0.200.89.192.61660Type 241.616126/0.405.042/0.301.424/0.200.86.154.936525209/0.405.066/0.301.424/0.200.86.458.844035285/0.405.090/0.301.424/0.200.86.762.250950380/0.405.0120/0.301.440/0.200.87.166.259270203/0.675.039/0.671.440/0.200.87.471.272795259/0.675.048/0.671.440/0.200.87.974.8835120336/0.675.060/0.671.440/0.200.88.380.2990150427/0.675.077/0.671.440/0.200.88.684./0.675.091/0.671.440/0.200.89.090./0.675.0119/0.671.440/0.200.89.696./0.675.0156/0.671.440/0.200.810.2103.61900Type 241.1125209/0.407.666/0.301.824/0.200.87.873.264535285/0.407.690/0.301.824/0.200.88.176.672450380/0.407.6120/0.301.840/0.200.88.580.682570203/0.677.639/0.671.840/0.200.88.985.797595259/0.677.648/0.671.840/0.200.89.389./0.677.660/0.671.840/0.200.89.794./0.677.677/0.671.840/0.200.810.098./0.677.691/0.671.840/0.200.810.4104.21610
Other supplier products
|
|
|
S15 BFOU-HCF(i) 250 V Fire Resistant Instrument cable NEK 606Applications :These cables are fire resistant,Website:, flame retardant, low smoke and... |
|
|
|
Type W Two-Conductor Round Portable Power Cable 2kVApplicationsThese cables are designed for general use where baregrounding conductors are not req... |
|
|
|
Type G Four-Conductor Portable Power Cable 2kV ICEA S-75-381ApplicationsThese cables are designed for use with mobile mining equipment,Website:, su... |
|
|
|
3.8/6.6kV,Website:, 6.35/11kV, 8.7/15kV HF-EPR Insulated, SW2/SW4 Sheathed Unarmoured Flame Retardant Power & Control CablesApplication:These mediu... |
|
|
|
3.6/6KV,Website:, 6/10KV, 8.7/15KV, (FA-)SPYC, SPYCB, TPYC (FA-)SPYCY, SPYCBY, TPYCYStandards:JISC 3410-1999
IEC 60092-350
IEC 60092-35... |
供应产品
Same products