H05V2V2-F/H05V2V2H2-F

VDE Industrial Cables H05V2V2-F/H05V2V2H2-F Application and DescriptionThese cables are suitable for domestic premises,Website:, kitchen, office for light service or light portable apparatuses. With their special insulation and sheatd compounds these cables are adapt for apparatus in kitchen and heating and for use in zones with high temperature (like lighting system apparatuses) without contact with warm parts and radiations. Unsuitable for outdoor use, in industrial and agricultural buildings or non-domestic portable tools. The maximum conductor temperature in normal use: 90°C.While high temperature use, skin contact must be avoidedStandard and ApprovalHD 21.12; HD 308 S2, DIN VDE 0281 part 1, part 12, DIN VDE 0293 part 308, DIN VDE 0295CEI 20-20/12, CEI 20-35 (EN60332-1) / CEI 20-37 (EN50267), CENELEC HD 21.12 S1 /EN50265-2-1Cable Construction- Bare copper fine wire conductor- Stranded to DIN VDE 0295 cl. 5, IEC 60228 cl. 5 and HD 383- PVC core insulation T13 to VDE-0281 Part 1- Green-yellow grounding (3 conductors and above)- Color coded to VDE-0293-308- PVC outer jacket TM3Technical Characteristics- Working voltage: 300/500 volts- Test voltage: 2000 volts- Flexing bending radius: 15 x Ø- Static bending radius: 4 x Ø- Flexing temperature: +5º C to +90º C- Static temperature: -40º C to +90º C- Short circuit temperature: +160º C- Flame retardant: IEC 60332.1- Insulation resistance: 20 MΩ x kmCable ParameterAWGNO. OF CORES X NOMINAL CROSS SECTIONAL AREA # X MM²NOMINAL THICKNESS OF INSULATIONMMNOMINAL THICKNESS OF SHEATHMMNOMINAL OVERALL DIAMETERMMNOMINAL COPPER WEIGHTKG/KMNOMINAL WEIGHTKG/KMH05V2V2-F18(24/32)2 x 0.750.60.86.214.454.218(24/32)3 x 0.750.60.86.621.66518(24/32)4 x 0.750.60.87.12977.718(24/32)5 x 0.750.60.983697.317(32/32)2 x 1.000.60.86.41960.517(32/32)3 x 1.000.60.86.82973.117(32/32)4 x 1.000.60.97.6389317(32/32)5 x 1.000.60.98.348111.716(30/30)2 x 1.500.70.87.42982.316(30/30)3 x 1.500.70.98.143104.416(30/30)4 x 1.500.71.0958131.716(30/30)5 x 1.500.71.11072163.114(30/50)2 x 2.500.81.09.248129.114(30/50)3 x 2.500.81./50)4 x 2.500.81.110.996199.614(30/50)5 x 2.500.81.212.4120245.412(56/28)3 x 4.000.81.211./28)4 x 4.000.81.212./28)5 x 4.000.81.413./28)3 x 6.000.81.113./28)4 x 6.000.81.313.9230490H05V2V2H2-F18(24/32)2 x 0.750.60.84.2 x 6.814.14817(32/32)2 x 1.000.60.84.4 x 7.21957
Other supplier products
|
|
|
S13 BU(i) 250 V Individual Shielding fire resistant NEK606 Instrument cableApplications :These cables are fire resistant,Website:, flame retardant,... |
|
|
|
Flame Retardant CAT5e Data CablesCAT5e U/UTP4P24CAT5e F/UTP4P24CAT5e SF/UTP4P24Application:Cat5E is a cable standard for Gigabit Ethernet and other... |
|
|
|
German Standard Industrial Cables JE-LiHCHApplication and DescriptionJE-LiHCH halogen-free cable with improved characteristics in the case of fire ... |
|
|
|
450/750V XLPE Insulated,Website:, PVC Sheathed Power Cables (2-4 Cores) CU/XLPE/PVC 450/750V Class 2Application:The cables are mainly used in power... |
|
|
|
P5 or P5/P12 BFOU 0.6/1KV Fire Resistant NEK606 Power cableApplications :These cables are fire resistant,Website:, flame retardant, low smoke,halog... |