RHH/RHW-LS/USE, XLPO, LSOH, CSA AWM I A/B, Class

UL Industrial Cables RHH RHW-LS USE,Website:, XLPO, LSOH CSA AWM I A B, ClassApplication and DescriptionRHH/RHW-2/USE-2, XLPO type is for use in conduit, open tray, underground duct and aerial installations when properly supported and installed, RHH/RHW ratings is for installation in conduit or raceway,USE rating is for direct burial applications and CT rated for installation in cable tray(1/0 AWG and larger), it is for use in all closed environments or populated spaces such as auditoriums, arenas and healtd facilities where more stringent specifications for smoke and toxicity emission levels are desired, for use in broad range of commercial, industrial and utility applications where reliability is the major concern, where maximum performance will be demanded and where space is limited.Cable ConstructionConductorTinned coated copper per ASTM B3 and B33. Class I stranding per ASTM B8InsulationFlame-retardant, oil-resistant, limited smoke, Cross-Linked Polyolefin (XLPO)Colorupon request, black is preferableTechnical Characteristics- UL 44 - Thermoset-Insulated Wires and Cables- UL 758 - Appliance Wiring Material- UL 854 - Service Entrance Cables.- UL 1685 - UL Vertical Tray Fire- ICEA S-95-658 (NEMA WC70)- IEEE 1202 (70,000 BTU/hr)- IEEE 383 (70,000 BTU/hr)- Telcordia GR347 Core- UL Listed VW-1- CSA FT4- CSA Standard C22.2 No. 0.3 and No. 210.2- Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP metdod- OSHA acceptableCable ParameterAWG OR KCMILSTRAND(CLASS B)CONDUCTOR DIAMETER INCH/MMNOMINAL INSULATION THICKNESS INCH/MMNOMINAL OVERALL DIAMETER INCH/MMCOPPER WEIGHTLBS/KFT KG/KMCABLEWEIGHTLBS/KFT KG/KM1470.071.780.0451.140.174..092.290.0451.140.194..123.050.0451.140.225..153.810.0601.520.287..184.570.0601.520.317..235.840.0601.520.369..287.110.0601.520.4210..328.130.0802.030.4912./0190.369.140.0802.030.5313./0190.4110.410.0802.030.5814./0190.4611.680.0802.030.6316./0190.5112.950.0802.030.6817..5614.220.0952.410.7619..6616.760.0952.410.8722..7920.070.0952.411.0025..9724.640.1102.791.2130.
Other supplier products
|
|
|
NTSKCGERLOEU Medium-Voltage Coal Cutter Cable VDE 0250 Part 813ApplicationsThese cables are used for the connection of mobile electrical equipment ... |
|
|
|
600/1000V XLPE Insulated,Website:, PVC Sheathed, Screened Power Cables (3C+3E)CU/XLPE/CUTO/PVC 600/1000V Class 2Application:The cables are designed... |
|
|
|
Armoured Cat 5e SF/UTP 24AWG IEC60092ApplicationThese Cat5e SF/UTP cables are manufactured in accordance with IEC 61156-5 requirements,Website:, ca... |
|
|
|
300/500V Mica+SR Insulated & Overall screened fire resistant control cables (2-4 cores& Multicores)(CU/MGT+SR/OS/LSZH 300/500V Class 1)(PH120) (CU/... |
|
|
|
F6 AICI NEK606 optical fibre cableApplications :These optical fibre cables are fire resistant,Website:, flame retardant, low smoke and halogen free... |