FDT-1371 Automatic Water Titrator

FDT-1371 Automatic Water Titrator

Specifications

It is suitable to determine water content in the liquid petroleum products by titration using Karl Fischer reagent.

Purpose:

FDT-1371 Automatic Water Titrator is designed and made as per the National Standard GB/T11143 & GB/T7600“Test Methods for Water Content of Liquid Petroleum Products (Karl Fischer Methods)”. It is suitable to determine water content in the liquid petroleum products by titration using Karl Fischer reagent. Adopt a microprocessor for control, so it has characteristics of rapid determination speed, high precision, LCD display, and automatic print. It also has function of self-diagnostics, menu selection. It is a multifunctional, convenient, and automatic analysis instrument.

Features

1, large-screen LCD, man-machine dialogue interface with menu prompts for various parameters;

2, with the trial date, clock and other parameters prompts;

3, differential detection, automatic correction system deviation;

4, the mixing, detection, print data microcomputer automatically completed;

5 ug water and ppm units automatically converted;

6 introduction the U.S. imports XECOM data processing chip, fast and accurate processing of the data;

Technical parameters

Measuring range: 3μg ~ 100mg

2, electrolytic speed: 2.4 mg / min (max)

3 Resolution: 0.1μg

4, accuracy: 10μg ~ 1mgH2O ± 3μg, to greater than 1mgH2O not more than 0.3% (excluding injection error)

5, end of show: information display, buzzer indicator endpoint

6, showing the clock: year, month, day, hour minute second (retentive)

7, printer: 44 mm wide and 16 character dot matrix printing paper

8, power supply voltage: AC220V ± 10%, frequency: 50Hz ± 5%

9. Size: 290×380×120 (mm);

10. Weight: 9 Kg;

FDT-1371 Automatic Water Titrator

Specifications

It is suitable to determine water content in the liquid petroleum products by titration using Karl Fischer reagent.

Purpose:

FDT-1371 Automatic Water Titrator is designed and made as per the National Standard GB/T11143 & GB/T7600“Test Methods for Water Content of Liquid Petroleum Products (Karl Fischer Methods)”. It is suitable to determine water content in the liquid petroleum products by titration using Karl Fischer reagent. Adopt a microprocessor for control, so it has characteristics of rapid determination speed, high precision, LCD display, and automatic print. It also has function of self-diagnostics, menu selection. It is a multifunctional, convenient, and automatic analysis instrument.

Features

1, large-screen LCD, man-machine dialogue interface with menu prompts for various parameters;

2, with the trial date, clock and other parameters prompts;

3, differential detection, automatic correction system deviation;

4, the mixing, detection, print data microcomputer automatically completed;

5 ug water and ppm units automatically converted;

6 introduction the U.S. imports XECOM data processing chip, fast and accurate processing of the data;

Technical parameters

Measuring range: 3μg ~ 100mg

2, electrolytic speed: 2.4 mg / min (max)

3 Resolution: 0.1μg

4, accuracy: 10μg ~ 1mgH2O ± 3μg, to greater than 1mgH2O not more than 0.3% (excluding injection error)

5, end of show: information display, buzzer indicator endpoint

6, showing the clock: year, month, day, hour minute second (retentive)

7, printer: 44 mm wide and 16 character dot matrix printing paper

8, power supply voltage: AC220V ± 10%, frequency: 50Hz ± 5%

9. Size: 290×380×120 (mm);

10. Weight: 9 Kg;



在线联系供应商

至: Changsha Friend Experimental Analysis Instrument Co., Ltd
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Shear stability of polymer-containing oil meter (ultrasonic method) FDH-1301
Shear stability of polymer-containing oil meter (ultrasonic method) FDH-1301 Application range Grease wide temperature range drop point determination of the instrument applicable standards: GB/T3498 ASTMD2265 Scope: Determi...
ofully automatic saturation vapor pressure tester (Reid method)	FDR-0271
ofully automatic saturation vapor pressure tester (Reid method) FDR-0271 Product Name: high vacuum vacuum distillation range tester Product Type: FDR-0331 Minimum Order Quantity: 1set Tags: Distillation range, distillat...
Automatic flash tester of petroleum products (Cleveland open cup method)
Automatic flash tester of petroleum products (Cleveland open cup method) Application range Oil density meter series GB/T1884-92 "petroleum and liquid petroleum products densitometry (densimeter law) according to the ...
Hydraulic oil filter analyzer FDH-5901
Hydraulic oil filter analyzer FDH-5901 Application range The hydraulic oil filter analyzer meets SH / T 0210, Determination of petroleum-based molding Hop various types of hydraulic oil ...
Hydrolytic stability of hydraulic oil analyzer FDH-5801
Hydrolytic stability of hydraulic oil analyzer FDH-5801 Application range Hydrolytic stability of hydraulic oil analyzer assay hydrolytic stability accordance with SH/T0301-93 hydraulic fluid (bottle ...
供应产品

Same products

Shin-Estu KE-20 1KG with CAT-RA 50G Grease a Set for General Molding
Shin-Estu KE-20 1KG with CAT-RA 50G Grease a Set for General Molding 卖方: 广东聚广恒自动化设备有限公司 Shinetsu KE20colour grey 1KG
Mobil Polyrex EM 103 16kg for Electric-Motor Bearings
Mobil Polyrex EM 103 16kg for Electric-Motor Bearings 卖方: 广东聚广恒自动化设备有限公司 Mobil Polyrex™EMelectric motor bearing grease provides excellent bearing performance and pr...
Liquid Gear Saphira Lubricant HP 2 1KG
Liquid Gear Saphira Lubricant HP 2 1KG 卖方: 广东聚广恒自动化设备有限公司 Lubricant HP 2Multipurpose LiquidGreaseFluidgreasefor high pressure
CRC STA-LUBE SL3330  396G High Temperature Grease
CRC STA-LUBE SL3330 396G High Temperature Grease 卖方: 广东聚广恒自动化设备有限公司 An aluminum complex premium grade NSF H1greasefor use in food production and processing industries
MULTEMP PS2 NO.2  2.5KG Extreme Low Temperature Grease
MULTEMP PS2 NO.2 2.5KG Extreme Low Temperature Grease 卖方: 广东聚广恒自动化设备有限公司 KYODO YUSHIMULTEMPSRL Ultra-low temperature grease for high-speed bearings