PV Degradation Testing Chamber

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Applications

The Light Decay Test Chamber is designed as an indoor exposure system, primarily used for standard module and cell degradation testing, module hot spot testing, and module pre-treatment. Spectral matching, irradiance uniformity, and irradiance stability meet at least BBB-grade standards.

This system comprises a light source system, temperature control system, module support structure, light source control system, and irradiance monitoring system. Utilizing xenon lamps as the light source, the irradiance across the exposure surface can be steplessly adjusted between 400 and 1200 W/m².

Standards

IEC 61215: Terrestrial photovoltaic (PV) modules—Design qualification and type approval (Specifically the Light-Induced Degradation and Hot-spot tests).

IEC 60904-9: Photovoltaic devices—Part 9: Classification of solar simulator characteristics (Meeting BBB or higher standards).

GB/T 9535: Ground-based silicon solar photovoltaic modules—Design qualification and type approval.

IEC 61646: Thin-film terrestrial photovoltaic (PV) modules—Design qualification and type approval (Stabilization phases).

Features

1. Utilizes a xenon lamp as the light source, providing an irradiation area of 1m x 2m, with over-temperature power-off protection.

2. Records irradiance, chamber temperature, and provides both instantaneous irradiance and cumulative irradiation data.

3. Chamber employs air cooling, with internal temperature controllable within 20°C to 50°C.

Parameters

CategoryItemSpecifications
1. Xenon Lamp Parameters Dimensions 200*40mm
Power 1800W
Operating Voltage 180VAC
Lamp Life 700h (with cumulative timing function for lamp tube)
2. Chamber Structure Construction Welded integral structure
Outer Wall Material Galvanized steel sheet (spray-painted)
Inner Wall Material SUS304 stainless steel sheet
Insulation Material Glass fiber or polyurethane foam material
Accessories Equipped with standard viewport: 1 multi-layer glass window (with work light)
3. Radiometer Spectral Range 300 ~ 3000nm
Irradiance Range 0 ~ 2000W/m²
Annual Stability 2%
Azimuth Response Error 5%
Non-linearity 2%
Temperature Error 2% (-10°C ~ 40°C)
4. Temperature Sensor Type PT100
Measurement Range -200 ~ 500°C
Test Accuracy ±1°C
Resolution 0.1°C
Probe Diameter Φ5mm
Installation Method Fixed with movable screws
Probe Length 5cm
Resistance Change 0.3851Ω/°C
Lead Connection Method Three-wire type
Sleeve Material Stainless steel 304

Test Procedures

1. Site: Level ground with good ventilation, free from flammable, explosive, or corrosive gases and dust. No strong electromagnetic radiation sources nearby. Adequate maintenance space around equipment.

2. Environmental Conditions:

Temperature: 5°C to 35°C

Relative Humidity: ≤85% RH

Atmospheric Pressure: 86–106 kPa

3. Power Supply:

AC 380V, three-phase four-wire + protective earth wire;

Voltage tolerance range: AC (1±10%) 380V

Allowable frequency fluctuation range: (1±1%) 50Hz

Protective earth grounding resistance must be less than 4Ω; TN-S or TT power supply system

Users must install an appropriately rated air or power circuit breaker at the installation site, dedicated exclusively to this equipment

4. Storage Environment Requirements:

When the equipment is not in operation, the ambient temperature must be maintained between +5°C and 35°C.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Socks wear tester
Socks wear tester Product Introduction: Socks wear tester is a special equipment, mainly used to test the wear resistance of socks material. It evaluates the comfor...
Battery Isothermal Calorimeter
Battery Isothermal Calorimeter Battery Isothermal Calorimeter is a professional instrument developed based on the principle of power compensation isothermal calorimetry for testi...
Standard light source sample table
Standard light source sample table Standards ISO 3664:2009: Meets international standards for graphic arts and photography view conditions. DIN 6173-2: European norm for illuminant...
Automotive High-Low Temp & Humidity Chamber
Automotive High-Low Temp & Humidity Chamber Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications 1. Automotive R&D Testing Cold Start Test: Verifies engine starting perf...
Paper roughness tester for quality control
Paper roughness tester for quality control Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Paper Roughness and Air Permeability Tester (TMI) simultaneously measures the...
供应产品

Same products

Walk-in Environmental Constant Temperature and Humidity Test Chamber
Walk-in Environmental Constant Temperature and Humidity Test Chamber 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T2423.3 Environmental Testi...
High reliability walk-in heat aging chamber
High reliability walk-in heat aging chamber 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Walk-in High-Temperature Ag...
Fully programmable walk-in climate simulation system
Fully programmable walk-in climate simulation system 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications High and Low Temperature Hu...
PV Degradation Testing Chamber
PV Degradation Testing Chamber 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Light Decay Test Chambe...
PV module acid corrosion test equipment supplier
PV module acid corrosion test equipment supplier 卖方: Standard International Group (HK) Limited Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Photovoltaic Acid Mist ...