PV Degradation Testing Chamber
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Applications
The Light Decay Test Chamber is designed as an indoor exposure system, primarily used for standard module and cell degradation testing, module hot spot testing, and module pre-treatment. Spectral matching, irradiance uniformity, and irradiance stability meet at least BBB-grade standards.
This system comprises a light source system, temperature control system, module support structure, light source control system, and irradiance monitoring system. Utilizing xenon lamps as the light source, the irradiance across the exposure surface can be steplessly adjusted between 400 and 1200 W/m².
Standards
IEC 61215: Terrestrial photovoltaic (PV) modules—Design qualification and type approval (Specifically the Light-Induced Degradation and Hot-spot tests).
IEC 60904-9: Photovoltaic devices—Part 9: Classification of solar simulator characteristics (Meeting BBB or higher standards).
GB/T 9535: Ground-based silicon solar photovoltaic modules—Design qualification and type approval.
IEC 61646: Thin-film terrestrial photovoltaic (PV) modules—Design qualification and type approval (Stabilization phases).
Features
1. Utilizes a xenon lamp as the light source, providing an irradiation area of 1m x 2m, with over-temperature power-off protection.
2. Records irradiance, chamber temperature, and provides both instantaneous irradiance and cumulative irradiation data.
3. Chamber employs air cooling, with internal temperature controllable within 20°C to 50°C.
Parameters
| Category | Item | Specifications |
|---|---|---|
| 1. Xenon Lamp Parameters | Dimensions | 200*40mm |
| Power | 1800W | |
| Operating Voltage | 180VAC | |
| Lamp Life | 700h (with cumulative timing function for lamp tube) | |
| 2. Chamber Structure | Construction | Welded integral structure |
| Outer Wall Material | Galvanized steel sheet (spray-painted) | |
| Inner Wall Material | SUS304 stainless steel sheet | |
| Insulation Material | Glass fiber or polyurethane foam material | |
| Accessories | Equipped with standard viewport: 1 multi-layer glass window (with work light) | |
| 3. Radiometer | Spectral Range | 300 ~ 3000nm |
| Irradiance Range | 0 ~ 2000W/m² | |
| Annual Stability | 2% | |
| Azimuth Response Error | 5% | |
| Non-linearity | 2% | |
| Temperature Error | 2% (-10°C ~ 40°C) | |
| 4. Temperature | Sensor Type | PT100 |
| Measurement Range | -200 ~ 500°C | |
| Test Accuracy | ±1°C | |
| Resolution | 0.1°C | |
| Probe Diameter | Φ5mm | |
| Installation Method | Fixed with movable screws | |
| Probe Length | 5cm | |
| Resistance Change | 0.3851Ω/°C | |
| Lead Connection Method | Three-wire type | |
| Sleeve Material | Stainless steel 304 |
Test Procedures
1. Site: Level ground with good ventilation, free from flammable, explosive, or corrosive gases and dust. No strong electromagnetic radiation sources nearby. Adequate maintenance space around equipment.
2. Environmental Conditions:
Temperature: 5°C to 35°C
Relative Humidity: ≤85% RH
Atmospheric Pressure: 86–106 kPa
3. Power Supply:
AC 380V, three-phase four-wire + protective earth wire;
Voltage tolerance range: AC (1±10%) 380V
Allowable frequency fluctuation range: (1±1%) 50Hz
Protective earth grounding resistance must be less than 4Ω; TN-S or TT power supply system
Users must install an appropriately rated air or power circuit breaker at the installation site, dedicated exclusively to this equipment
4. Storage Environment Requirements:
When the equipment is not in operation, the ambient temperature must be maintained between +5°C and 35°C.
Send product request
Other supplier products
| Back & Butt Forms Testing Apparatus for Seat and Cushion Evaluation | Whats/App: +86 156 1874 6768 Web: standard-groups.com 5th Percentile Female SAE Butt Form The 5th Percentile Female SAE Butt Form is meticulousl... | |
| Protective Clothing Liquid Static Pressure Resistance Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Protective Clothing Liquid Static Pressure Resistance Tester is designed to evaluate th... | |
| Chest Drainage Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The thoracic drainage tester is widely applied in the medical field, mainly used for monito... | |
| High Efficiency Oil Water Separation Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards ISO/TS 16332-2006 – Method for evaluating fuel water separation efficiency... | |
| Filter Media Test Rig According To ISO11057,air filter efficiency and pressure drop tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com The Filter Media Test Rig According to ISO 11057 is designed for reliable and repeatable te... |
Same products
| Two-Shot Injection Molds | Seller: WIT MOLD LIMITED | Two-Shot Injection Molds Advantages of two-shot injection molding The benefits of Double Inject... | |
| precision injection molding | Seller: WIT MOLD LIMITED | precision injection molding Precision injection moldingis a method demanding unparalleled accura... | |
| Custom Plastic Molds molding | Seller: WIT MOLD LIMITED | Custom Plastic Molds molding Plastic Molds molding servicesprovide many extremely versatile part... | |
| Thermoset Molding | Seller: WIT MOLD LIMITED | Thermoset Molding Key Aspects of Thermoset Molding Materials: Thermosetting Polymers:These inc... | |
| PE Film Scrap, Rolls, Bale, Regrinds, Lump, LLDPE, HDPE, LDPE | Seller: Plastic scrap, ferrous and non-ferrous metal scraps supplier for recycling | We have PE film scrap, including LLDPE, HDPE, and LDPE, available for ongoing shipment to buyers ... |