Fully programmable walk-in climate simulation system
Whats/App: +86 156 1874 6768
Web: standard-groups.com
Applications
High and Low Temperature Humidity Test Chamber is designed for performance and reliability testing of electric vehicle power batteries. It can be integrated with battery performance testing systems and is also suitable for research and development, matching, and other tests involving power batteries and battery management systems.
Standards
GB/T 2423.1: Environmental testing methods for electrical and electronic products - Test A: Low-temperature test method
GB/T 2423.2: Environmental testing methods for electrical and electronic products - Test B: High-temperature test method
GB/T 2423.3: Environmental testing methods for electrical and electronic products - Constant humidity and heat test method
GB/T 2423.4: Environmental Testing Methods for Electrical and Electronic Products - Alternating Humidity and Heat Test Method
GB/T 10586-2006: Technical Conditions for High and Low Temperature Test Chambers
GB/T 10592-2023: Technical Conditions for High and Low Temperature Test Chambers
IEC 62660-4 Lithium-ion batteries for electric road vehicle propulsion
GB/T 31484-2015 Cycle life requirements and test methods for power batteries used in electric vehicles
Features
1. Comprehensive Safety Protection: Equipped with explosion-proof devices, automatic fire suppression systems, and gas detection units to ensure testing safety.
2. Intelligent Operation and Energy Efficiency: Supports program control and remote monitoring, utilizes fluorine-free refrigerants and energy-saving technologies, and complies with environmental standards.
Parameters
| No. | Item | Specifications |
|---|---|---|
| 1 | Inner Chamber Volume | 12 m³ |
| 2 | Inner Chamber Dimensions | 3000mm (W) × 2000mm (D) × 2000mm (H) |
| 3 | Temperature Range | -45°C ~ +100°C (adjustable) |
| 4 | Temperature Fluctuation | ≤ 0.5°C (no load, steady state) |
| 5 | Temperature Uniformity | ≤ 2°C (no load, steady state) |
| 6 | Temperature Deviation | ≤ ±2°C (no load, steady state) |
| 7 | Heating Rate | ≥ 2°C/min (room temperature ~ 85°C, with non-linear load of 1000kg battery pack) |
| 8 | Cooling Rate | ≥ 1.0°C/min (room temperature ~ -40°C, with non-linear load of 1000kg battery pack) |
| 9 | Humidity Range | 20% ~ 98% RH (adjustable) |
| 10 | Humidity Deviation | - Humidity > 75% RH: ≤ ±2~3% RH- Humidity ≤ 75% RH: ≤ ±5% RH |
| 11 | Humidity Fluctuation | ≤ 2% RH |
| 12 | Humidity Uniformity | - Humidity > 75% RH: ≤ ±2~3% RH- Humidity ≤ 75% RH: ≤ ±5% RH |
| 13 | Air Pressure Balance System | Equipped with an air pressure balance valve, which opens automatically under a certain pressure difference |
Test Procedures
1. Pre-Operation Preparation
Ensure power cords and grounding wires are securely connected.
Open the chamber door, remove any debris inside, and verify proper sealing.
Check refrigerant levels and ensure the water inlet contains adequate clean water (manual water addition required for some models).
2. Parameter Settings
Set high temperature (e.g., 80°C), low temperature (e.g., -40°C), and humidity (e.g., 95% RH) via the control panel.
Configure preheating duration, constant temperature duration, and cycle count (e.g., 5 cycles).
3. Sample Placement
Place the power battery inside the chamber, close the door, and wait for preheating to complete.
If testing ports are required, connect cables and secure them.
4. Initiate Testing
Press the power button to start operation according to the set parameters.
Monitor sample conditions closely during testing and record temperature, humidity, and other data.
5. End of Operation
After testing concludes, turn off the power and clean any accumulated water or debris from the chamber.
在线联系供应商
Other supplier products
| Bone Plates Four-point Bending Fatigue Tester | Standard YY/T 1503-2016: Chinese standard specifying test methods for bending fatigue properties of metallic bone plates, requiring 1 million ... | |
| Guide pin anchoring force tester | The Guide Pin Anchoring Force Tester is designed to evaluate the anchoring performance of mammary positioning wires and guide needles. It ensures t... | |
| Gas Oxidizing Property Tester | Product Description Conforms to ISO 10156-2010 “Gases and Gas Mixtures Selection of Cylinder Valve Exhaust Ports by Determination of Combust... | |
| Paper roughness tester for quality control | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Paper Roughness and Air Permeability Tester (TMI) simultaneously measures the... | |
| Filter Media Test System丨Filter Media System | Filter Media Test System Gellowen has developed its filter media testing system of G505 for the determination of particle concentration, dust pene... |
Same products
| Walk-in Environmental Constant Temperature and Humidity Test Chamber | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standards GB/T2423.3 Environmental Testi... | |
| High reliability walk-in heat aging chamber | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications Walk-in High-Temperature Ag... | |
| Fully programmable walk-in climate simulation system | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications High and Low Temperature Hu... | |
| PV Degradation Testing Chamber | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Light Decay Test Chambe... | |
| PV module acid corrosion test equipment supplier | 卖方: Standard International Group (HK) Limited | Whats/App: +86 156 1874 6768 Web: standard-groups.com Applications The Photovoltaic Acid Mist ... |