Ultraviolet accelerated aging test chamber

Whats/App: +86 156 1874 6768

Web: standard-groups.com

Standards

(1)IEC 61215 Terrestrial Photovoltaic (PV) Modules – Design Qualification and Type Approval

(2)IEC 61646 Thin-Film Terrestrial Photovoltaic (PV) Modules – Design Qualification and Type Approval

Parameters

ItemTechnical Specification
Structural material High UV-blocking, high-sealing, high-thermal-insulation specialized material
Total UV irradiation area ≥2000 mm × 2000 mm
Maximum test capacity Simultaneous testing of 2 photovoltaic modules (2 m × 1 m each)
Light source type Xenon lamp
Lamp lifetime (single set) Approx. 1000 h
Spare lamps 1 set (standard configuration)
System cumulative service life ≥2000 h
UVA / UVB energy ratio UVB accounts for approx. 3%–10% of total energy
Irradiance intensity Approx. 100 W/m² in the 280–385 nm range
280–320 nm proportion ≤10%
Irradiance uniformity Better than ±15%
UVA probe 320–385 nm, fiber-optic type
UVB probe 280–320 nm, fiber-optic type
Module surface temperature 60 ℃ ±5 ℃
Temperature resolution 0.1 ℃
Temperature measurement accuracy ±0.1 ℃
Ozone generation Negligible
Irradiation method Top irradiation, light source vertically directed at module surface
Control mode Touchscreen control with automatic monitoring and light source cut-off

Features

Large irradiation area suitable for full-size photovoltaic module testing

Independent UVA and UVB dual-band monitoring compliant with IEC standard requirements

High irradiance intensity effectively shortens test duration

Precise irradiance uniformity control ensures consistency and comparability of test results

Real-time module surface temperature monitoring prevents non-UV-related thermal degradation

Extremely low ozone generation avoids additional material aging effects

Touchscreen human–machine interface enables intuitive parameter setting and traceable operation status

Accessories

(1)Xenon lamp set (standard configuration)

(2)UVA fiber-optic probe (320–385 nm)

(3)UVB fiber-optic probe (280–320 nm)

(4)High-precision surface temperature sensor

(5)Control system (touchscreen and control module)

(6)Dedicated power supply and connection components

Test Procedures

Confirm normal status of the light source, temperature sensors, and irradiance probes before testing

Install photovoltaic modules according to standard requirements, ensuring the irradiated surface is perpendicular to the light source

Set irradiance intensity, test duration, and module surface temperature

Start the ultraviolet aging test and monitor system parameters in real time

Keep the chamber door closed throughout the test to prevent ultraviolet leakage

If irradiance or temperature exceeds preset limits, the system automatically cuts off the light source

After test completion, allow modules to cool to a safe temperature before removal

Maintenance Information

Regularly inspect xenon lamps and replace them according to specified service life

Periodically calibrate UVA and UVB probes to ensure measurement accuracy

Check temperature sensors and control systems for stable operation

Keep the irradiation chamber clean to maintain irradiance uniformity

Verify sealing components to prevent UV leakage and ensure operator safety


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

 Dental Implants Fatigue Tester
Dental Implants Fatigue Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard ISO 14801:2016: Specifies dynamic fatigue testing protocols for endosseous dental...
Fabric Bending Length Evaluation Instrument
Fabric Bending Length Evaluation Instrument Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Textile Material Feel Style Evaluator is a precision instrument designed ...
IEC 60331 Cable Fire Resistance Test Equipment Supplier
IEC 60331 Cable Fire Resistance Test Equipment Supplier Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com E-mail:info@standard-groups。com Technical Specifications ItemTechnical ...
Minimum Ignition Energy (MIE) – Dust Cloud Tester
Minimum Ignition Energy (MIE) – Dust Cloud Tester Whats/App: +86 156 1874 6768 Web: standard-groups.com Dust Cloud Minimum Ignition Energy Tester disperses a certain mass of dust specimen to be t...
Medical injection needle puncture force tester
Medical injection needle puncture force tester Whats/App: +86 156 1874 6768 Web: standard-groups.com The Medical Injection Needle Puncture Force Tester is a precision instrument designed to ev...
供应产品

Same products

Dissolved Air Flotation
Dissolved Air Flotation 卖方: 864117 Dissolved Air Flotation What Is Dissolved Air Flotation? , also known as DAF, is a wate...
Waste Gas Treatment Equipment
Waste Gas Treatment Equipment 卖方: 864117 Waste Gas Treatment Equipment Mingzhou provides reliable for industrial exhaust gas purifica...
Fiber Ball Filter
Fiber Ball Filter 卖方: 864117 Fiber Ball Filter MG-GLX Fiber Ball Filter are filtration systems or filter media that util...
Chemical Wastewater Treatment
Chemical Wastewater Treatment 卖方: 864117 Chemical Wastewater Treatment provides advanced Chemical Wastewater Treatment solutions for ...
Dyeing and Printing Wastewater Treatment
Dyeing and Printing Wastewater Treatment 卖方: 864117 Dyeing and Printing Wastewater Treatment Mingzhou provides advanced solutions for textile, d...