Nonwovens liquid loss tester

Nonwovens liquid loss tester built-in loss of Taiwan and sample fixture for non-woven fabric materials for a specific test fluid slip and loss of performance.

Standards compliant:
Edana152.0-99; ISO9073-11

The main purpose:
Non-woven fabric liquid loss tester _ liquid slip and loss of the tester built-in loss of Taiwan and sample fixture for non-woven fabric materials for a specific test fluid slip and loss of performance.

The main parameters :
1, flow control range: 6.10mL / s ~ 6.41 mL / s;
2, slip and drain Taiwan angle control: 25 °;
3, slip and loss length: 250 ± 0.2mm;
4, timing: 60s, accuracy: ± 0.1s;
5, slip and loss Weight: 30g ± 0.01g.

Main features of thefabric liquid loss tester:
1, with the requirements of the requirements of the loss of Taiwan and sample fixture;
2, having a dose device capable of giving a 25 mL test solution in a continuous stream within (4 ± 0.1) s;
3, the test liquid out of time manual operation, automatic recording, digital display;
4, can be equipped with loss of weighing system.

Test principle:
A standard absorbent medium is placed under the nonwoven fabric to be measured and the combined sample is placed on a sloping pad to measure that when a particular amount of artificial urine flows down to the combined sample, the liquid penetrates the nonwoven Standard Absorbent Media Absorption, the liquid loss performance of the nonwovens sample was obtained by weighing the weight of the mass of the media prior to testing.



在线联系供应商

至: 千实精密机电仪器检测设备有限公司
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

Filter Media Tester TVE 3000
Filter Media Tester TVE 3000 TVE 3000 for vacuum cleaner tests with dust in accordance with the standard EN 60312With the aid of the TVE 3000, vacuum cleaner tests can be carri...
Auto Air Permeability Test  Apparatus for Fabric
Auto Air Permeability Test Apparatus for Fabric Auto Air Permeability Test Apparatus for Fabric is used for fast, simple, and accurate determination of the air permeability of all kinds of flat m...
Oscillator Abrasion Tester
Oscillator Abrasion Tester StandardASTM D4157:Standard Test Method for Wear Resistance of Textiles (Swing Roller Method) Applications Oscillator Abrasion Tester is also nam...
High Temperature Oxygen Index Tester
High Temperature Oxygen Index Tester Introduction:The high temperature oxygen index tester is designed and de-veloped according to ISO4589-3 (Elevated-temperature test) and British Nav...
ASTM F2101 bacterial Filtration Efficiency (BFE)Tester
ASTM F2101 bacterial Filtration Efficiency (BFE)Tester Medical face mask Bacterial filtration efficiency Tester can quickly and accurately measure the filtration efficiency of filtration protection equi...
供应产品

Same products

安泰信 ST-2065D ST-2080D ST-2150D 数字电烙铁
安泰信 ST-2065D ST-2080D ST-2150D 数字电烙铁 卖方: 深圳市维客修科技有限公司 描述 ATTEN ST-2065D ST-2080D ST-2150D 便携式电烙铁带LED数字显示,65W 80W 150W可选,80℃-480℃可调温度,适用于手机PCB、...
TBK-988X多功能旋转液晶加热分切机
TBK-988X多功能旋转液晶加热分切机 卖方: 深圳市维客修科技有限公司 2024 TBK 988X加热分离机采用反向分离手机屏幕技术,避免损坏偏光片并保持屏幕完好。TBK 988X恒温加热平台与TBK002除胶剂配合使用,用于LCD OCA脱胶。TBK BK-002...
APF-4.0A-4KW with 1978-4540 volume 1120-668 pressure POPULA air purification box
APF-4.0A-4KW with 1978-4540 volume 1120-668 pressure POPULA air purification box 卖方: Popula Group Company 九洲普惠集团公司Limited Puduct Name: APF-4.0A-4KW with 1978-4540 volume 1120-668 pressure POPULA air purification box ...
HTFC-I-30-III-15KW with  volume 620-535pressure POPULA Fan Fire Cabinet Fan Single Speed Centrifugal Fan
HTFC-I-30-III-15KW with volume 620-535pressure POPULA Fan Fire Cabinet Fan Single Speed Centrifugal Fan 卖方: Popula Group Company 九洲普惠集团公司Limited Puduct Name: HTFC-I-30-III-15KW with volume 620-535pressure POPULA Fan Fire Cabinet Fan Singl...
JQZ-4.5A-5.5KW-2P with 1169-3542 CMH volume 3378-1856 pressure POPULA Broken Edge Paper Centrifugal Fan High Pressure
JQZ-4.5A-5.5KW-2P with 1169-3542 CMH volume 3378-1856 pressure POPULA Broken Edge Paper Centrifugal Fan High Pressure 卖方: Popula Group Company 九洲普惠集团公司Limited Puduct Name: JQZ-4.5A-5.5KW-2P with 1169-3542 CMH volume 3378-1856 pressure POPULA Broken Edge P...