Thermal Protective Performance Tester
Get a quote:
Whats/App: +86 185 0176 3615
Web: qinsun-lab.com
The thermal protection performance (TPP) tester is mainly used to test the thermal insulation properties of horizontally placed flame retardant protective clothing fabrics exposed to radiant and convective heat sources.measuring the resulting damage to human skin.
Highlights:
Automatic test operation provides repeatable and precise results
Independently controlled radiant heat source and convective heat source
Water-cooled shutter is pneumatically actuated for precise exposure control
Standards
(1) BS EN ISO 6942 – Protective clothing – Protection against heat and flame – Method of test for the determination of heat transfer on exposure to a heat source
(2) EN 366 – Protective clothing against heat and flame – Resistance of materials to contact heat
(3) EN 407 – Protective gloves against thermal risks (heat and/or fire)
(4) ISO 11612 – Protective clothing – Clothing to protect against heat and flame
(5) ASTM F1939 – Standard Test Method for Evaluation of Thermal Protective Performance of Materials for Clothing
(6) ASTM F2702 – Standard Test Method for Heat Transfer and Thermal Protective Performance of Flame Resistant Clothing Materials Using a Thermal Protective Performance Tester
(7) NFPA 1971 – Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting
(8) NFPA 2112 – Standard on Flame-Resistant Garments for Protection of Industrial Personnel Against Flash Fire
(9) GB 38543 – Technical Specification for Fire Protection of Workwear for Industrial Personnel
(10) GB/T 38306 – Test Method for Thermal Protective Performance of Flame Retardant Protective Clothing
Principle:
Under exposure to a specified heat flux, the time to second-degree burns is derived from the intersection point of the response curve (temperature rise curve of the calorimetric sensor) and the human tissue tolerance curve (Stoll curve). The higher the product of the heat flux level and the time to second-degree burns, the stronger the thermal protective performance of the fabric.
Feature:
Standard calorimeter mounting block.
PLC control system provides stable and fast testing performance.
Analysis software with user friendly interface is easy to use and installed Stoll curve model internally.
Compact structure design reduces the requirements of fume hood.
Evaluates the potential for skin burns associated with a fabric’s ability to block convective and
radiant heat penetration
Automatic test operation provides repeatable and precise results
Independently controlled radiant heat source and convective heat source
Supports up to three copper disk calorimeter sensor assemblies
Integrated air-cooled sensor stand quickly prepares calorimeter sensor for next test
Water-cooled shutter is pneumatically actuated for precise exposure control
Automatically predicts time to second degree burn, with results shown as a real-time numerical and graphical display of sample performance compared to the Empirical Performance Curve
Small and portable, the TPP test device fits in most standard fume hood
Technical Parameters
| Heat Flux Measurement Range | 0–167 kW/m² |
| Heat Flux Measurement Accuracy | ±2 kW/m² |
| Specimen Irradiated Size | ≥200mm*200mm,for testing flame-retardant protective clothing, fire-fighting suits and protective gloves |
| ConvectionHeatSource | 2Merkel lamps (Heat flux: up to 60 kW/m²; Radiant heat flux: up to 40 kW/m²) |
| Rotor Propane Gas Flowmeter | Provides precise, stable propane flow for the burner |
| Radiant Heat Source | 9pcs of500W infrared quartz lamps (proportional power controlfor0–30 kW/m²radiant heat flux) |
| ASTM F2703Copper Calorimeter | Accuracy±3% F.S.;Weight 1000±10 g |
| Copper Calorimeter Copper Plate | Imported Oxygen-Freesuperconductingcopper |
| Data Acquisition System Sampling Rate | ≥20samples/second |
| Environment | 15–35℃ |
| Fume Hood | Recommended internal dimensions ≥150×75×90 cm, including door height |
| Gas Source | Propane (Purity≥95%, equipped with pressure reducing valve - cylinder & outlet pressure controlled) |
| Compressed Air | Customer-supplied |
| Cooling Water Source | Tap water (inlet & outlet) or optional chiller |
| Power supply | Single phaseAC220V 50Hz |
| Dimension | 130×65×53cm (LXWXH) |
| Weight | Around 60kg |
在线联系供应商
Other supplier products
| Fabric Down-Proof Impact Tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com The first sample is made of bags which built a cert... | |
| Thermal Protective Performance Tester (TPP) - lab instrument | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com The Thermal Protective Performance (TPP) Test Devic... | |
| Fabric Static Stress Resistance Tester - lab instrument | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Email: serving@qinsun-lab。com Product Name Fabric Static Stress Resistance Teste... | |
| KM-5A Particle Abrasion Tester | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The KM-5A particle attrition tester is specially designed according to the test me... | |
| HEPA Filter Element Quality Control Test System | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The HEPA Filter Element Quality Control Test System is designed for quality contro... |
Same products
| Tabletop Xenon Arc Weathering Tester (SunMaster) | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Water-Cooled Xenon Lamp Weat... | |
| Blow-By Test Rig | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Test system for the characterisa... | |
| Air filter System(ISO 16890/EN 779) | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Filter test system for general a... | |
| Oil Thread Leak Test System | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com Test System for oil thread leak ... | |
| Manual HEPA/ULPA Filter Scanning Test System | 卖方: Standard Groups | Get a quote: Whats/App: +86 185 0176 3615 Web: qinsun-lab.com The Manual HEPA/ULPA Filter Scan... |