The PVT Coolant Pulse Test Machine is designed for testing automotive cooling components, with a particular focus on rubber coolant hoses. It integrates linear vibration and eccentric rotation mechanisms, enabling automatic leak detection and leak testing. The machine is equipped with an automatic shutdown function for failed samples, ensuring safety and efficient testing workflows.

Application

You can use the PVT Coolant Pulse Test Machine to evaluate the durability, functionality, and leak resistance of automotive cooling system components. Typical applications include:

Testing rubber coolant hoses and tubes under dynamic pressure conditions.

Evaluating seals and connectors in cooling systems.

Simulating real-world vibration and thermal stress on components.

Integrating with automotive testing standards for component reliability.

Commonly used testing products with this machine:

Rubber coolant hoses

Plastic connectors and fittings

Cooling system assemblies

Automotive engine cooling components

Standards

The PVT Coolant Pulse Test Machine complies with a broad range of international automotive standards, including:

VW 78007 / TL 82048 / TL 81165 / TL 874 (4.4) – Volkswagen Group specifications for cooling system and interior material performance

TL 82002 / TL 52682 / TL 886 / TL 889 / TL 82086 – Volkswagen Group specifications for system component material performance and durability

PV 1712 (Ag 99-03) / GMW3155 – Fiat / General Motors engineering specifications for materials and component performance

PTL14052-A1203 / PTL14100-A0911 – Internal technical standards for component functionality and reliability

BMW LH 10356681 (10.5) / LH 10757369 (6.) / QV 17004 – BMW Group engineering specifications for material and component functionality and durability

BMW LH 7823444.6 / LH 10591317 / LH 10274837 – BMW Group engineering specifications for system component performance and functional validation

DIN 73411-2 [39] / Daimler M139 (2) / M177 (2) – Daimler engineering specifications / German industrial standards for component material and functional testing

Parameters

ParameterDetails
Machine Dimensions 4350 mm × 2520 mm × 2150 mm (W × H × D)
Test Chamber Internal Dimensions 1800 × 1000 × 1000 mm (W × H × D)
Rated Power 60 kW
Test Medium Glycol / Water
Pressure Range 0 … 5 bar
Medium Flow Control Up to approx. 100 l/min
Linear Motion ±25 mm at 1 Hz ±12 mm at 5 Hz ±6 mm at 10 Hz ±2 mm at 20 Hz
Test Medium Temperature Range -40°C … +150°C
Environment Temperature Control Range -40°C … +150°C
Test Channels 8

Features

Combines linear and eccentric motion mechanisms for pressure pulse testing.

Operates in a pressure range of 0.1 … 5 bar.

Heats the test chamber by monitoring maximum surface temperature limits.

Automatic leak detection and leak testing with shutdown of failed samples.

Integrated recirculation pump prevents coolant leakage.

Windows / LabView-based control unit for data acquisition and monitoring.

Accessories

Test hoses and fittings

Data acquisition sensors

Leak detection probes

Temperature control modules

Linear and eccentric motion actuators

Test Procedures

Install the component to be tested in the test chamber.

Connect the test medium (glycol/water) and set the desired flow rate.

Configure test parameters including pressure range, linear/eccentric motion frequency, and temperature range.

Start the test via the Windows/LabView control unit.

Monitor real-time data for pressure, temperature, and leak detection.

The machine will automatically stop and alert you if a sample fails.

Record and export test results for analysis.

Maintenance Information

Regularly check and clean the recirculation pump and medium lines to prevent blockages.

Inspect motion actuators for wear and lubricate as recommended.

Calibrate pressure and temperature sensors periodically to ensure accurate testing.

Clean the test chamber and remove any residue from previous tests.

Update the control software and verify data acquisition integrity.


在线联系供应商

至: Standard International Group (HK) Limited
Your E-mail:
消息正文:


Send to other suppliers

Other supplier products

ASTM G99 Pin-on-Disc Tribometer Manufacturer
ASTM G99 Pin-on-Disc Tribometer Manufacturer Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Pin-on-Disc Friction and Wear Tester is designed for evaluating the frict...
Air filter System(ISO 16890/EN 779),air filter performance testing apparatus
Air filter System(ISO 16890/EN 779),air filter performance testing apparatus Whats/App: +86 156 1874 6768 Web: standard-groups.com Filter test system for general air filters according to ISO 16890. EN 779. ASHRAE 52.2 The...
Sliding Bearing Fatigue Testing Machine
Sliding Bearing Fatigue Testing Machine Whats/App: +86 156 1874 6768 Web: standard-groups.com The sliding bearing fatigue testing machine is an important testing device, mainly used to ...
Rubber Mooney Viscosity meter
Rubber Mooney Viscosity meter Whats/App: +86 156 1874 6768 Web: standard-groups.com Test principle: The Mooney viscometer is used to measure the viscosity of rubber under spe...
Industrial Cleanable Filter Media Test System Manufacturer
Industrial Cleanable Filter Media Test System Manufacturer Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com E-mail:info@standard-groups。com Parameters ParameterUnitValue Te...
供应产品

Same products

MMA-120 Handheld Arc Welder
MMA-120 Handheld Arc Welder 卖方: 871183 The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con...
SHX Series Circulating Fluidized Bed Steam Boiler
SHX Series Circulating Fluidized Bed Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi...
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler
YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ...
DHL Series Coal-Fired Steam Boilers
DHL Series Coal-Fired Steam Boilers 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b...
SZL Series Biomass Steam Boiler
SZL Series Biomass Steam Boiler 卖方: Hebei Genjux Boiler Co.,Ltd Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi...