The test system serves laboratory testing according to VDI 3956 (Test method for the dust soiling behaviour of solar energy systems).
This includes tests on the behaviour of glass surfaces under the influence of dusting, changing air humidity and glass temperature and the resulting condensation effects as well as cleaning by wind.
Experiments on other test specimens exposed to these environmental conditions are also possible.
Applications
tests according to VDI 3956
temperature-dependent dusting and cleaning tests of other types of samples
Standard
VDI 3956-1
Technical data
| Parameter | Unit | Value |
|---|---|---|
| Air flow velocity | m/s | ≤ 15 |
| Test specimen dimensions | mm | Thickness ≤ 10 |
| Specimen holder | – | Base area 200 × 200 mm; setting angle 0 … 60° (discrete) |
| Test conditions | – | Environmental temperature and relative humidity (controlled) |
| Compressed air supply (operating gas/air) | bar | 6 … 10 (quality class ISO 8573-1:2010 [6:4:2]) |
| Power supply | – | 3 – TN-C-S network/PEN; 400 VAC, 50 Hz |
| Test chamber dimensions | mm | 700 × 720 × 700 |
| Aerosol generation technology | – | Dust disperser SAG 410 |
| Power consumption | W | max. 6000 |
| Noise emission | dB(A) | LpA ≤ 76.7 ± 1.5 |
| Dimensions (W × H × D) | mm | 2107 × 890 × 1647 |
| Weight | kg | approx. 450 (including devices) |
Features
adjustable angle of the sample holder
selectable dust dosing positions
data logger
largely automated processes
optimised handling
Principle
The test specimen is mounted on a sample holder in an air lock and then drawn into the preconditioned main chamber. The air lock prevents the dust-containing atmosphere from entering the environment. The desired angle of the specimen is set (up to 60° to the horizontal). The environmental scenarios to be investigated are imitated using the following equipment:
- dusting using generator with dual-positionable nozzle
- temperature control of sample holder: with heating mat/cooling unit
- blowing off the sample using a movable air blade
When air is introduced into the chamber by dust dosing, humidification or sample cleaning, a negative pressure must be present in the chamber to prevent the emission of dust into the atmosphere.
Maintenance Information
Regularly clean the dust generator and chamber interior to ensure consistent test conditions.
Check seals and air-lock components to maintain negative pressure integrity.
Verify airflow velocity, temperature, and humidity sensors periodically.
Inspect compressed air quality to comply with ISO 8573-1 requirements.
Perform routine system calibration according to laboratory quality procedures.
在线联系供应商
Other supplier products
| ASTM E1354 cone calorimeter | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com The Cone Calorimeter is a precision fire-testing instrument designed to evalu... | |
| Automatic sandbag load testing equipment | Whats/App: +86 156 1874 6768 Web: standard-groups.com Application The machine is widely used for mechanical performance testing and structural v... | |
| UV Lamp Aging Test Tester | Whats/App: +86 156 1874 6768 Web: standard-groups.com Standard JTG E50 T1164: Testing methods for geosynthetics in highway engineering. GB/T 14... | |
| Bag fastener magnetic buckle testing machine | Whats/App: +86 156 1874 6768 Web: standard-groups.com Product Introduction: This machine is mainly used to test the durability of the finished m... | |
| Engine blow-by test equipment manufacturer | Get a quote: Whats/App: +86 156 1874 6768 Web: standard-groups.com Test system for the characterisation of the oil content in blow-by gases at e... |
Same products
| MMA-120 Handheld Arc Welder | 卖方: 871183 | The MMA-120 Handheld Arc Welder from ChuangLi Electronic Technology Co., Ltd. is designed for con... | |
| SHX Series Circulating Fluidized Bed Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 10-35 t/hWorking pressure: 1.25-2.5 MPaOperating temperature: 194-400 ℃Applicable to bi... | |
| YQ(Y)W Series Oil/Gas Fired Vertical Thermal Oil Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 7000-29200 KWOperating pressure: 0.8-1.0 MPaOperating temperature: 320℃Operating mode: ... | |
| DHL Series Coal-Fired Steam Boilers | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 35-75 t/hOperating pressure: 1.25-5.4 MPaOperating temperature: 194-485℃Applicable to b... | |
| SZL Series Biomass Steam Boiler | 卖方: Hebei Genjux Boiler Co.,Ltd | Capacity: 6-35 t/hWorking pressure: 1.0-2.5 MPaOperating temperature: 184-350 ℃Applicable fuel bi... |