Thermal Conductivity Tester(Light/Laser Flash Method),light flash thermal conductivity measurement device for electronics materials
Transient Laser Flash Thermal Conductivity Tester is a high-precision instrument designed to measure thermal diffusivity and thermal conductivity of high-conductivity solid materials, such as metals, diamond, graphite, and other advanced materials. Based on the laser flash method, the instrument delivers a short, high-intensity energy pulse to the sample surface, causing a temperature rise on the rear surface. The time to reach half of the maximum rear-surface temperature (half-rise time) is recorded and processed by a dedicated mathematical model to calculate thermal diffusivity and thermal conductivity. The instrument offers rapid measurement, high accuracy, wide temperature applicability, and non-contact testing, making it indispensable for research, industrial quality control, and production monitoring.
Application
The tester is suitable for testing thermal properties of:
Metals, alloys, and advanced ceramics
Graphite, graphene, silicon carbide, diamond
Thermal interface materials and high-conductivity composites
Applications include:
Materials research in universities and institutes
Quality control in industrial production
R&D laboratories for advanced thermal management materials
Rapid thermal testing for both research and industrial applications
Standards
The instrument complies with the following international and national standards:
GB/T 22588-2008
Flash Method for Measuring Thermal Diffusivity or Thermal Conductivity of Materials
ASTM E1461-2022
Standard Test Method for Thermal Diffusivity of Solids by the Flash Method
GB/T 42919.4-2023
Plastics – Determination of Thermal Conductivity and Thermal Diffusivity – Part 4: Laser Flash Method
ISO 22007-4:2017
Plastics – Determination of Thermal Conductivity and Thermal Diffusivity – Part 4: Laser Flash Method
Parameters
| Item | Specification |
|---|---|
| Sample size | Ø12.5 × 0.5–5 mm; square 10 × 10 mm; thickness 1–5 mm |
| Thermal conductivity range | 0.1–2000 W/m·K |
| Thermal diffusivity range | 0.1–1000 mm²/s |
| Accuracy | Thermal diffusivity ±4%, Specific heat ±5% |
| Test temperature range | Room temperature; RT–200 °C, RT–300 °C, RT–500 °C (optional) |
| Temperature precision | ≤0.1 °C with high-temperature inert gas protection |
| Heating rate | ≥5 K/min |
| Repeatability | Deviation <±3% |
| Laser source | Max 15 J/pulse, pulse width 0.1–10 ms, continuous adjustment, software controlled |
| Laser spot | Adjustable |
| Detector | Infrared MCT-CT, air-cooled |
| Sampling frequency | Up to 200 kHz |
| Control system | PLC + Windows, fully automatic software for measurement, analysis, and report generation |
| Power supply | AC 220 V, 500 W |
Features
High-precision transient laser flash method for thermal diffusivity and conductivity
Non-contact testing, suitable for small samples
Rapid measurement, wide temperature range (room temperature to 500 °C)
Suitable for metals, ceramics, graphite, diamond, graphene, silicon carbide
Accurate data processing via dedicated mathematical models
Full automation: laser control, temperature control, data acquisition, calculation, and report generation
Optional high-temperature inert gas protection for reactive materials
Accessories
Main instrument
Analysis software package
Computer (e.g., Lenovo or user-specified)
Calibration reference samples (2 pieces)
Graphite spray (imported, 3 bottles)
Test Procedures
Prepare a flat, parallel sample with precise thickness measurement.
Apply graphite coating on transparent or semi-transparent samples, if necessary.
Place the sample in the copper sample holder and align it precisely with the laser and infrared detector.
Set laser pulse energy, pulse width, and temperature parameters via the control software.
Start the measurement sequence; the system automatically controls the laser pulse, temperature, and data acquisition.
Record the rear-surface temperature rise and compute half-rise time.
Use the software to calculate thermal diffusivity and thermal conductivity.
Review, store, and export the measurement report.
Maintenance Information
Keep laser optics clean and free from dust.
Ensure the sample holder and infrared detector are properly aligned.
Replace graphite spray bottles as needed for accurate absorption on transparent samples.
Maintain stable AC power supply and proper environmental conditions.
Perform regular calibration using reference samples to ensure measurement accuracy.
在线联系供应商
Other supplier products
| Automatic voltage internal resistance tester | Standard ASTM E83: Standard Test Method for Verification of Linear Displacement Measuring Systems ISO 3611: Calibration of Measuring Instruments ... | |
| Surface Roughness/Friction Tester STD-SESRU, ASTM D1894 anti-wear property tester for fabric | The Surface Roughness / Friction Tester is an upgraded version of the FB4-A instrument, designed to evaluate the frictional feel and surface roughn... | |
| Vertical Fire Testing Furnace,Vertical Flammability Chamber,ISO 834 | Description: Fire resistance performance of material provide important information for evaluation samples and Assembly properties. This furnace is... | |
| Face Mask Tensile Tester | Introduction: The test machine uses the integrated structure of the motor and the speed control system to drive the synchronous belt deceleration ... | |
| Bonding Strength Measuring Instrument | The tack - holding tester, also known as the tack - holding property tester, tack - holding force tester, or holding - power tester, is a device sp... |